My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
749
>
2300 - Underground Storage Tank Program
>
PR0231060
>
COMPLIANCE INFO_2017 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:48 PM
Creation date
11/8/2018 10:25:27 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017 - 2018
RECORD_ID
PR0231060
PE
2361
FACILITY_ID
FA0003870
FACILITY_NAME
SRH FOOD & GAS
STREET_NUMBER
749
Direction
E
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
14734309
CURRENT_STATUS
01
SITE_LOCATION
749 E DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\D\DR MARTIN LUTHER KING JR\749\PR0231060\COMPLIANCE INFO 2017 -PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2017 -PRESENT
QuestysRecordDate
3/28/2018 9:47:28 PM
QuestysRecordID
3839032
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ask 40 <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sioov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SRH FOOD & GAS 749 E DR MARTIN LUTHER KIND JR BLVD, May 22, 2017 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR-Notice to Comply) <br /> Item # Remarks <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator(DO)failed to document the correct product in the underground storage tanks when <br /> completing the designated operator monthly inspection reports for October 4, 2016 and November 21, 2016. <br /> Beneath UST System Inspection, under Spill containment structures are free of water, debris, and hazardous <br /> substance, the DO listed Tank 1, regular, Tank 2 plus, but there is no plus tank at this facility, Tank 3 premium and <br /> omitted the diesel tank located at this facility. Also there was no panel printout of alarm histories for the August 1, <br /> 2016 DO monthly inspection report. During the monthly inspection, the designated operator shall review the alarm <br /> history for the previous month, check that each alarm was documented and responded to appropriately, and attach <br /> a copy of the alarm history with documentation taken in response to any alarms to the monthly report. Ensure that <br /> designated operators performing monthly inspections at this facility are including all of the required information on <br /> the reports. <br /> This is a repeat violation, Class II. <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003). <br /> The 87-product 407 annular sensor failed to activate an audible and visual alarm when tested and, therefore, the <br /> tank is not monitored. The interstitial space shall be monitored with a monitoring system connected to an audible <br /> and visual alarm system. Immediately contact a properly licensed, trained, and certified contractor to replace the <br /> failed component, with a functional component(LG 113-x listed, if applicable), like-for-like within one business day. <br /> Notify the Environmental Health Department a scope of work and time and date of the repair work to <br /> UST@sjcehd.com. The service company must install the part and test the system to verify functionality. The <br /> service company must provide the following documentation to the tank owner/operator for inspector review during <br /> the annual UST inspection: 1. Description of part(s) installed 2. Name and UST ICC number of service technician <br /> doing the work(manufacturer certification proof)and 3. testing done to verify functionality of the repair. <br /> This is a minor violation. <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The diesel submersible turbine pump (STP)sump 208 sensor was raised approximately one-and-a-half inches off <br /> the lowest point of the sump and not located to detect a leak at the earliest opportunity. Monitoring equipment shall <br /> be maintained to be able to detect a leak at the earliest possible opportunity. The sensor was relocated to the <br /> lowest point of the sump by the service technician. Ensure that all monitoring equipment is maintained to detect a <br /> leak at the earliest opportunity. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> FA0003870 PR0231060 SC001 05/22/2017 <br /> EHD 23-01 Rev.09/22/16 Page 4 of 5 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.