My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ESCALON
>
1329
>
2300 - Underground Storage Tank Program
>
PR0231487
>
INSTALL_2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2023 4:32:34 PM
Creation date
11/8/2018 10:25:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2017
RECORD_ID
PR0231487
PE
2351
FACILITY_ID
FA0000293
FACILITY_NAME
Pershing Holdings, Inc. DBA Esclon Arco
STREET_NUMBER
1329
STREET_NAME
ESCALON
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22510003
CURRENT_STATUS
01
SITE_LOCATION
1329 Escalon Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\E\ESCALON\1329\PR0231487\2017 INSTALL.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
445
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Program Element: 2303 - UST/PIPING INSTALLATION <br />Telephone: (209) 595-0787 Requestor: PAUL RAJ, CHADHA CONSTRUCTION <br />Inspection Type: 131 - UST INSTALLATION INSPECTION <br />Address: 1329 ESCALON AVE , ESCALON 95320 <br />Date: 10/02/2017Name of Facility: ARCO AM PM <br />Underground Storage Tank Program Service Request Inspection Report <br />Time Out: <br />Time In: <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, CA 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: www.sjgov.org/ehd <br />Request #: SR0074800 <br />Onsite Service Technician: ICC Service Tech/Installer Exp. Date: <br />Manufacturer training: <br />OVERALL INSPECTION NOTES AND COMMENTS <br />NOTES <br />On site for the following inspections: <br />Verification of communication in the product piping secondary containment. This was conducted by the installer using <br />pressurized piping. <br />The vapor recovery line, the 91 product line, the 87 product line, the 91 vent line and the 87 vent line were tested. <br />Communication was observed in the lines tested. <br />Note: Vacuum system communication still needs to be conducted after fuel delivery. <br />Verification of the dispenser footprints contained by the under dispenser containment (UDC) sumps. <br />It was observed that the product piping and the filters were contained by the UDC unit. <br />Verification of VPH components installed on the UST system. <br />VPH components were not installed on the 87 fill sump during the time of inspection. <br />Verified location and installation of UDC units brine reservoirs in accordance with the manufacturer's instructions. <br />Verified that the sensor holders for the 208 sensors in the UDC units were raised off of the UDC floor. <br />Additional inspections are needed before fuel can be dropped in the line. <br />The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br />Safety Code. If a reinspection is required, fees will be assessed at the current hourly rate. <br />Received by: Name and Title: <br />EH Specialist:Phone:(209) 468-3147 <br />Engel Molina, Installer <br />JOHN ALANIZ <br />Page 1 of 1EHD 23-01 Rev. 06/30/15 Underground Storage Tank Program Service Request Inspection Report <br />FA0000293 SR0074800 SC131 10/02/2017
The URL can be used to link to this page
Your browser does not support the video tag.