Laserfiche WebLink
Document management portal powered by Laserfiche WebLink 9 © 1998-2015 Laserfiche. All rights reserved.
IVIFIED PROGRAM CONSOLIDATED FORT <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN- 2 <br /> 'aaaaaa (Page 1 of <br /> TYPE OF ACTION ❑ L NEW PLAN X 2.CHANGE OF INFORMATION 490.1 <br /> PLAN TYPE X I.MONITORING IS IDENTICAL FOR ALL USTS AT THIS FACILITY. 4o2 <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> I <br /> I. FACILITY INFORMATION <br /> FACILITY ID a(Agency Ute Dnly) <br /> _ _ 1 <br /> BUSINESS NAME(Some o3 Focflrly Name or DBAJ <br /> Shell/Tesoro 88150 <br /> BUSINESS SITE ADDRESS 13975 E. Highway 88 103 <br /> CITY Lockeford 1a <br /> II. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,Sensors,probes,Jim leak detectors,etc.)must be performed at the frequency specified <br /> by the equipment manufacturers'instructions,or annus y,whichever is more frequent Such work must be performed ualified rsonnel. 3 ccR 632_1634,tae.2641 <br /> _��_ 'J<_I 4'- I <br /> MONITORING EQUIPMENT IS SERVICED X I.ANNUALLY ❑ 99.OTHER(Specify): 090'3. <br /> 49636 <br /> III. MONITORING LOCATIONS <br /> ❑ L NEW SITE PLOT PLANIMAP SUBMITTED WITH THIS PLAN X 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED Ill CCR§2632,26301 +9264 <br /> IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) (Cheek' <br /> X I.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) +vas <br /> that <br /> WITH AUDIBLE AND VISUAL ALARMS.In CCR§263=.26341 <br /> SECONDARY CONTAINMENT IS: X a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ It UNDER VACUUM 490.6 <br /> PANEL MANUFACTURER: Gilbarco 490.7 MODEL p: EMC 990's <br /> _ LEAK SENSOR MANUFACTURER: Vesder Root 496A MODEL 8(S): 794390-420 440'10 <br /> 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGL WALL TANK( ).J13 CCR§1643) -TW 1-1 <br /> PANEL MANUFACTURER: 490.12. MODEL q: +90'13 <br /> IN-TANK PROBE MANUFACTURER: 490'14 MODEL g(S): 490-13 <br /> LEAK TEST FREQUENCY: ❑ &CONTINUOUS90.16 <br /> ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 4 <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): '9013 <br /> PROGRAMMED TESTS: ❑ a.0.(g.p.h. ❑ b.0.2&p.h. ❑ c.OTHER(Speci ): 49 18 <br /> 490.19 _ <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION f23COX§1646.11 4o n <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTD)[n ccR§2645] TESTING PERIOD: ❑ a.36 HOURS [I b.60 HOURS + 49az1 <br /> 9an <br /> ❑ 5.TANK INTEGRITY TESTING PER In CCR§x643.1) 49 D <br /> TEST FREQUENCY: _ [Ic.OTHER(Specify):a ANNUALLY ❑ b.BIENNIALLY ❑ °90.1° <br /> -_.. w4 <br /> X 99.OTHER(Specify): Tanks are monitored by Sacrificial Anodes. 190.=5 <br /> ,van <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) (Checka" <br /> that <br /> X 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490.25 <br /> [l uj SECONDARY CONTAINMENT IS: X a.DRY 4w" <br /> 4x5361 ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM <br /> PANEL MANUFACTURER:Giibarco 490-30 MODEL a: EMC 490.31 <br /> LEAK SENSOR MANUFACTURER: Veeder Root 49 31. MODEL g(S): 794380-208 49x33 <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e..TURBINE)SHUTDOWN. X a YES ❑ b.NO 49x34 <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. X a.YES ❑ b.NO 490.35 <br /> X 2. MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0&p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF 49x36 <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.In CCR§26361 <br /> 490.3] MODEL B(S): LD2000(87), FX1V 49 30. <br /> MLLD MANUFACTURER(S):Vapel'Iees-, Red jacket 8818 <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.(n CCRJM61 490.39 <br /> ELLD MANUFACTURER(S): 440.°0 MODEL N(S): 4v 1 <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 49°'41. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 49°43 <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. _ ❑ a YES ❑ b.NO 49044 <br /> - <br /> ❑ 4.PIPE INTEGRITY TESTING. 49643 <br /> TEST FREQUENCY: ❑ &ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify) 49x°6 <br /> 490.47 <br /> ❑ 5.VISUAL PIPE MONITORING. 4vo.4s <br /> FREQUENCY. ❑ a.DAILY ❑ b.WEEKLY ❑ C.MIN.MONTHLY&EACH TIME SYSTEM OPERATED• 49°.49 <br /> AMb.w fa npnir. d nbu M wfi�elpipi-1-' )t HS-�UMII 5bR33 <br /> [36.SUCTION PIPING MEETS EXEMPTION CRITERIA.(n CCR§2636(.)(3)1 49 " <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM, 49 11 <br /> ❑ 99.OTHER(Specify) - 4v 51 <br /> 490.53 <br /> UPCF UST-D(I2nW)-1/8 www.ald§ba.arg <br />