Laserfiche WebLink
San Joaquin County Ae,Environmental Health Department /°SMP TE <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 L.�l O <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd l <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> GEORGES BP MINI MART 1 18662 N HWY 88 LOCKEFORD March 30 2017 <br /> UST System Observations <br /> 322 HSC 25281.6(a) Unburied below grade emergency generator system failed to meet exemption status o V o R o COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status it V o R it COS <br /> 324 CCR 2717.1(g) Tampered with red tag o V o R o COS <br /> 325 CCR 2717.1(f) Deposited petroleum into a red tagged UST o V o R o COS <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms o V o R o COS <br /> 327 CCR 2631.1 UST system not compatible with the substance stored o V o R o COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements to V it R is COS <br /> 329 HSC 25298 Failed to comply with permanent closure requirements o V o R o COS <br /> 330 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system o V o R o COS <br /> Single-Walled Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V in R u COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(preJan 1984)not performed o V o R o COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1884) o V o R o COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) it V o R o COS <br /> Other Violations <br /> 2010 See below Unlisted Admintstration/Documentation violation is V oft o COS <br /> 2030 See below Unlisted Operations/Mainte lance violation o V o R o COS <br /> 2060 See below Unlisted Design/Construction violation it V o R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS ll,or MINOR-Notice to Comply) <br /> Item If Remarks <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions. <br /> The diesel STP 205 sump sensor was replaced with a 208 sensor on 1/11/17 and a permit was not obtained from the <br /> EHD. Emergency repairs relating to UST system monitoring and release detection may be performed by a properly <br /> licensed,trained, and certified contractor pursuant to the EHUS policy and a permit obtained within one business day <br /> from the EHD. All other repairs must have a permit submitted to and approved by the EHD prior to beginning work. <br /> Immediately obtain a permit from the EHD for the UST replacement. A"Failure to Obtain a Permit"penalty applies. <br /> This is a Class II violation. <br /> Page 3 of 4 <br />