Laserfiche WebLink
UST SYSTEM PRINTSET INFORMATION <br />TANK N <br />0 <br />ONE <br />0 <br />0 <br />X4rcOmPlete <br />sets of plans (To include specification sheets and/or equipment brochures if not on file). <br />2. <br />X <br />Plans drawn to scale in non -erasable print. <br />3. <br />X <br />Plot plan to show location and nuriber of tanks. <br />4. <br />X <br />Tank cross-sectional diagram included on prints submitted. <br />COMPOSITION <br />XDetail <br />of tank, piping system, excavation and cover. <br />6. <br />X <br />Tank(s) and piping approvedby a nationally recognized independent testing organization. [Title 23, Subchapter 16, <br />MODEL <br />T)WT 1000 <br />Article 3, Sec. 2631 (r) L 26351 <br />T. <br />X <br />Verification of product compatibility with the tank(s), piping, monitoring <br />PRODUCT <br />UL GASOLINE <br />device(s), epoxy or silicone glues, etc. [Section 2635 (b) (2)] <br />8. <br />X <br />Manufacturer's written installation instructions for tank(s), piping, monitoring devices, etc. (Section 2635 (b) (5)] <br />9. <br />�_ <br />Tightness Test (NFPA 30) is required on both primary (10) and secondary (20) containment systems before covering. <br />[Section 2635 (b) (6) 3 (T)] <br />10. <br />N / A <br />Double walled tanks using pressure or vacuum testing to monitor the annular space. (Section 2635 (b) (7)1 <br />11. <br />X <br />NFPA 329 "Precision Test" required upon completion of installation with tank in operating condition. Test results to <br />COMPATIBIL <br />METHANOL ITY WITH 100X <br />Y E S <br />be submitted directly to PHS/EHD from the testing company or owner of facility. (Health d Safety Code, Division 20, <br />Chapter 6.7, Section 25291 (g)) <br />12. <br />TANK COIPOSITIM <br />TANK N <br />0 <br />ONE <br />0 <br />0 <br />0 <br />0 <br />CAPACITY <br />1 000 <br />' <br />MANUFACTURER <br />COMPOSITION <br />MODEL <br />T)WT 1000 <br />PRODUCT <br />UL GASOLINE <br />CORROSION PROTECTION <br />N/A <br />U.L. LISTED <br />YES <br />COMPATIBIL <br />METHANOL ITY WITH 100X <br />Y E S <br />13. TANK(s) TO BE INSTALLED <br />A. Steel -clad with fiberglass reinforced plastic. <br />B. Holiday test required immediately before "setting" tank(s) (35,000 - 40,000 volts). (Section 2635 (b) (4)1 <br />, X C. Fiberglass [Sections 2635 (3) ar-A 2631 (p)] <br />(1) Striker plate dimensions and materials. <br />X (2) Striker plate under all accessible openings. <br />(3) Installation instructions require an air test and soap bubble test prior to installation. <br />LA D. Non -clad steel tank [Section 2635 (b)] <br />(1) Cathodic protection provided for entire tank, piping and compcxunts (nuts, bolts, washers, <br />etc.). <br />(2) Approved by a corrosion engineer or N.A.C.E. technician. <br />(3) Document stating inspection method and frequency (minirninsemi-anrnual inspection requirement). <br />4 <br />