Laserfiche WebLink
T 2:91 PREMIUM <br />.f <br />.r . <br />•PRODUCT CODE 2 <br />-" <br />THERMAL C:OEFF :.000700 <br />R 2:91 <br />TANK DIAMETER 114.00 <br />LIQUID SENSOR SETUP <br />TYPE: <br />TANK PROFILE 1 PT <br />- - - - - - - - - - - - <br />STANDARD <br />FULL VOL 5025 <br />NORMALLY CLOSED <br />L 1:DISP. 1-2 <br />TRI-STATE (SINGLE FLOAT) <br />FLOAT SIZE: 4.0 IN. <br />CATEGORY DISPENSER PAN <br />LIQUID SENSOR ALMS <br />L 1:FUEL ALARM <br />WATER WARNING 1.5 <br />L 2:FUEL ALARM <br />HIGH WATER LIMIT: 2.0 <br />L 3:FUEL ALARM <br />L 2:DISP. 3-4 <br />L 4:FUEL ALARM <br />MAX OR LABEL VOL: 5025 <br />TRI-STATE (SINGLE FLOAT) <br />L 5:FUEL ALARM <br />OVERFILL LIMIT 90% <br />CATEGORY DISPENSER PAN <br />L 6:FUEL ALARM <br />4522 <br />L 1:SENSOR OUT ALARM <br />HIGH PRODUCT 95% <br />L 2:SENSOR OUT ALARM <br />4773 <br />L 3:SENSOR OUT ALARM <br />DELIVERY LIMIT 10% <br />L 3:DISP. 5-6 <br />L 4:SENSOR OUT ALARM <br />502 <br />TRI-STATE (SINGLE FLOAT) <br />L 5:SENSOR OUT ALARM <br />CATEGORY DISPENSER PAN <br />L 6:SENSOR OUT ALARM <br />LOW PRODUCT 600 <br />L 1:SHORT ALARM <br />LEAK ALARM LIMIT: 99 <br />L 2:SHORT ALARM <br />SUDDEN LOSS LIMIT: 99 <br />L 3:SHORT ALARM <br />TANK TILT 0.00 <br />L 4:DISP. 7-8 <br />L 4:SHORT ALARM <br />PROBE OFFSET 0.00 <br />TRI-STATE (SINGLE FLOAT) <br />L 5:SHORT ALARM <br />CATEGORY DISPENSER PAN <br />L 6:SHORT ALARM <br />SIPHON MANIFOLDED TANKS <br />T#: NONE <br />LINE MANIFOLDED TANKS <br />L 5:87 STP <br />T#: NONE <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />LEAK MIN PERIODIC: 0% <br />0 <br />L 6:91 STP <br />TRI-STATE (SINGLE FLOAT) <br />LEAK MIN ANNUAL 0% <br />CATEGORY STP SUMP <br />0 <br />SMARTSENSOR SETUP <br />L 7:SPLIT ANNULAR <br />PERIODIC TEST TYPE <br />TRI-STATE (SINGLE FLOAT) <br />s 1:VEEDER-ROOT POLISHER <br />STANDARD <br />CATEGORY ANNULAR SPACE <br />CATEGORY VAPOR VALVE <br />ANNUAL TEST FAIL <br />s 2:PRESURE SEN. <br />ALARM DISABLED <br />CATEGORY VAPOR PRESSURE <br />PERIODIC TEST FAIL <br />s 8:AMTP <br />ALARM DISABLED <br />CATEGORY ATM P SENSOR <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />OUTPUT RELAY SETUP <br />TNK TST SIPHON BREAKOFF <br />R 1:87 <br />DELIVERY DELAY 3 MIN <br />TYPE: <br />PUMP THRESHOLD 10.00% <br />STANDARD <br />PMC SETUP <br />NORMALLY CLOSED <br />PMC VERSION: 01.02 <br />LIQUID SENSOR ALMS <br />VAPOR PROCESSOR TYPE <br />L 1:FUEL ALARM <br />VEEDER-ROOT POLISHER <br />L 2:FUEL ALARM <br />L 3:FUEL ALARM <br />L 4:FUEL ALARM <br />ANALYSIS TIMES <br />L 5:FUEL ALARM <br />TIME: 11:59 PM <br />L 6:FUEL ALARM <br />DELAY MINUTES: 1 <br />L 1:SENSOR OUT ALARM <br />L 2:SENSOR OUT ALARM <br />LEAK TEST METHOD <br />L 3:SENSOR OUT ALARM <br />-- - - -- - - - - -- <br />L4:SENSOROUTALARM <br />TEST ON DATE : ALL TANK <br />L 5:SENSOR OUT ALARM <br />JAN 29. 2009 <br />L 6:SENSOR OUT ALARM <br />START TIME : DISABLED <br />L 1:SHORT ALARM <br />TEST RATE :0.20 GAL/HR <br />L 2:SHORT ALARM <br />DURATION 2 HOURS <br />L 3:SHORT ALARM <br />L 4:SHORT ALARM <br />TST EARL`! STOP:DISABLED <br />L 5:SHORT ALARM <br />L 6:SHORT ALARM <br />LEAK TEST REPORT FORMAT <br />CO <br />NORMAL <br />