COMPLIANCE INFO_2013 - 2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
D
>
DR MARTIN LUTHER KING JR
>
701
>
2300 - Underground Storage Tank Program
>
PR0231059
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/3/2023 4:26:58 PM
Creation date
11/16/2018 11:31:38 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231059
PE
2361
FACILITY_ID
FA0002512
FACILITY_NAME
GSG GAS & MART
STREET_NUMBER
701
Direction
E
STREET_NAME
DR MARTIN LUTHER KING JR
STREET_TYPE
BLVD
City
STOCKTON
Zip
95206
APN
14734311
CURRENT_STATUS
01
SITE_LOCATION
701 E DR MARTIN LUTHER KING JR BLVD
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
295
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN _JOAOUIN <br />COUNTY <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />GSG GAS & MART <br />701 E DR MARTIN LUTHER KING JR BLVD, <br />June 06, 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />201 <br />CCR 2712(b) Failure to maintain monitoring, maintenance, and follow up action records. <br />Maintenance and monitoring records for the last three years were not found on site. Site has daily alarm log, but <br />failed to document an alarm occurring on 1/30/18, and incorrectly showed a check mark for that date. These <br />records shall be accurate and maintained on site for at least three years. Monitoring records include: (1) date and <br />time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results of any <br />visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges <br />or other monitoring equipment, ground water elevations, or other test results; (6) results of inventory readings and <br />reconciliations. Immediately locate and maintain all maintenance and monitoring records for the last three years on <br />site and submit copies to the EHD. <br />This is a Class II violation. <br />209 <br />CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator failed to document all the alarms from the attached alarm history on the January 2018 <br />designated operator monthly inspection report and failed to check that they were responded to appropriately. The <br />missing alarms include: an L8 dispenser 5-6 fuel alarm occuring on 1/19/18. During the monthly inspection, the <br />designated operator shall review the alarm history for the previous month, check that each alarm was documented <br />and responded to appropriately, and attach a copy of the alarm history with documentation taken in response to any <br />alarms to the monthly report. Ensure that designated operators performing monthly inspections at this facility are <br />including all of the required information on the reports. <br />This is a repeat violation, Class II. <br />308 <br />CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm. <br />The monitoring panel activated a visual alarm, but failed to activate an audio alarm when tested. During the <br />inspection, service technician pressed on the electronic sound horn, and the audio alarm worked for a brief period of <br />time. The audio alarm failed to alarm after retesting. All monitoring equipment shall be maintained to activate an <br />audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. Correct immediately by <br />having a properly licensed, trained, and certified contractor replace the failed component with a functional <br />component (LG 113-x listed, if applicable) and obtain a permit from the EHD if necessary. <br />This is a minor violation. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork within 30 days of receipt of this report. <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />FA0002512 PR0231059 SCO01 06/06/2018 <br />EHD 23-01 Rev. 10/31/2017 Page 4 of 5 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />