Laserfiche WebLink
SERVICE PRO° CONTROL CENTER <br />The Service Pro electrical control center with MCD technology <br />I......•1 rrlt.r aW." NnM <br />MODEL TNT <br />shall provide Monitoring, Compliance and Diagnostic functions NAMEPLATE O O <br />AUXILIARY INPUT <br />LABEL PAD <br />for the Singulair treatment plant using a microprocessor based ERVICE PRO" <br />Inrm: Sw.k 1. An .nnn <br />platform. The Service Pro control center shall contain nonvolatile POWER ONTROL CENTER <br />AUXILIARY 1 <br />memory to prevent loss of programming in the event of a power LIGHT telVltYl#O <br />LIGHT <br />TNT <br />failure. The pre -wired controls shall be mounted in a lockable °T. nnx°,EN <br />RERTME 1 <br />NEMA rated enclosure designed specifically for outdoor use. Each ALARM, " noroa <br />AUXILIARY INPUT <br />LIGHT <br />Service Pro control center shall be a UL listed assembly and <br />LABEL PAD <br />shall include a factory -programmed timer, alarm light, reset button, <br />n. <br />PHONE9 <br />power switch, power light, phone light, aerator alarm light and LIGHT "•" <br />AUXILIARY 2 <br />LIGHT <br />three auxiliary alarm lights. The control center shall monitor all <br />.A •<Iw. xc<arnn <br />treatment system operating conditions including aerator over AERATOR <br />AUXILIARY INPUT <br />current, aerator undercurrent and open motor circuit. In the event LIGHT•°' ° ° <br />O �.SERVICEPROMCD.COM <br />LABEL PAD <br />the control center detects one of these conditions, power to the <br />on= <br />aerator shall be interrupted, a diagnostic sequence shall begin RESET <br />p g q g <br />AUXILIARY3 <br />BUTTON ON <br />LIGHT <br />and the visual alarm shall activate. After a programmed recovery �IRnRWE <br />.lar.lr .tn. <br />,INC. <br />K, OHIO <br />interval, an automatic restart attempt shall be initiated. If normal <br />CONTROL CENTER <br />OFF <br />POWER <br />aerator operation does not resume during 24 programmed recovery INSERT <br />SWITCH <br />and restart cycles, the audible alarm shall activate and the <br />S.Mte Pro <br />telemetry system shall report the specific condition to the Service Pro monitoring center. In the event that any <br />of the auxiliary <br />inputs detect abnormal operation of the treatment system auxiliary equipment, the audible and visual alarms <br />shall immediately <br />activate and the telemetry system shall report the alarm condition to the monitoring center. The service provider shall automatically <br />be notified by the Service Pro monitoring center of the specific alarm condition using phone, fax or email. <br />»rvx.e p..r rqe. xk.rr.•m <br />AERATOR TIME CYCLE <br />A factory -programmed timer built into the Service Pro control center shall provide a total of twelve hours of aerator operation per <br />day. The non-adjustable timer shall create a 60 minute aeration cycle followed by a 60 minute anoxic cycle during which the <br />aerator shall be off. Use of an aerator timer can seriously affect system performance and operating cost. Systems that have not <br />been performance certified, at a timed aeration cycle, by an <br />_ independent ANSI accredited testing laboratory shall not be <br />considered for this application. <br />M +rah • •I.... <br />I......•1 rrlt.r aW." NnM <br />rAU <br />xeOe�Nl1'xe rl�elnr <br />eSl°u <br />Inrm: Sw.k 1. An .nnn <br />.1° ...L..nr. <br />.,aw••wx whr<nl�, I <br />,.rxxnll. xu <br />arrl•r pyl• yrm•nl <br />Ilu. 4..rn •: 14rwcb :r L: Mn. tr "' <br />.rrly ,,,nlurr. <br />ynr.�.n <br />d•yyr,<d to xlbw ee+Y ar<•n3ln <br />— <br />WWII, <br />av<mMh.ln-0— <br />x Ykxlkn m... l...r.d nn Ih. len <br />n. <br />rpKlAr •uou.n <br />0Ih. or" ro......PSA <br />.A •<Iw. xc<arnn <br />+ lnln<,..awn <br />y <br />.0 +.+IYnIxJ n:. vur,r',r <br />n qu.+1NNr aMNr rrr r.s. W <br />, { <br />�. <br />on= <br />IIM vrvh r fha munihNhW .nlrmi <br />.dd »r,+c• neon <br />.ad <«nr>•..n <br />c.n.. rr« me .N�. lkn* Iw.ar.d.t <br />rh< Iwn.m .N tlw m.•. <br />1 <br />.lar.lr .tn. <br />gauerN bx. lar <. n. <. <br />II Ynn havu n fD.<Illt nxw;IMn Iri <br />.+µlump <nnunm <br />r "p......r.«e. <br />�kY an tM'C*"*" U, <br />Ilnktk..l.d xl al. Wu!Ihi. <br />S.Mte Pro <br />GYIIlIeN1 <br />Wp• <br />control center <br />NirN. MU InWM:lMn1 <br />»rvx.e p..r rqe. xk.rr.•m <br />�»nnal wrrh.0 hxn. <br />wal fwm <br />dNnM <br />• v..Je. <br />www.servicepromcd.com <br />SERVICE PRO® MONITORING CENTER <br />The Service Pro monitoring center shall include a 128 bit encrypted <br />password protected website for interface with the monitoring center <br />database. Access to the secure website shall be obtained through <br />a unique user name and password that provides tiered access to <br />data from monitored treatment systems. Access level tiers shall <br />include distributors, service providers, regulatory agencies and <br />individual system owners. Distributors and service providers shall <br />be able to create accounts, maintain service records and grant <br />regulatory agencies access to the information. Individual system <br />owners shall be able to view information regarding their own <br />wastewater treatment systems, as well as download and print <br />instructional information. Integrity of stored data shall be <br />maintained through the use of multiple servers operating in <br />geographically isolated locations. <br />