SR0079781
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ALLEN
>
19263
>
4200/4300 - Liquid Waste/Water Well Permits
>
SR0079781
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2019 2:03:00 PM
Creation date
11/29/2018 2:50:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
4200/4300 - Liquid Waste/Water Well Permits
RECORD_ID
SR0079781
PE
4201
STREET_NUMBER
19263
Direction
E
STREET_NAME
ALLEN
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24507088
ENTERED_DATE
10/25/2018 12:00:00 AM
SITE_LOCATION
19263 E ALLEN RD
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
DAfonskaia
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
norweco 0 <br />S1NGULR1R"010=K1NET1C" <br />WASTEWATER TREATMENT SYSTEM WITH SERVICE PRO® CONTROL CENTER <br />MODELS 960 AND TNT® OWNER'S MANUAL <br />INTRODUCTION <br />The Singulair system is the finest equipment available <br />and utilizes the most up-to-date wastewater treatment <br />technology. It is a sound investment that protects you <br />and the environment. Please take the time to familiarize <br />yourself with the contents of this manual. <br />HOW THE SINGULAIR® SYSTEM WORKS <br />Developed to serve homes and small businesses beyond <br />the reach of city sewers, the Singulair system employs the <br />extended aeration process. Similar to the treatment method <br />used by most municipal <br />wastewater treatment OPTIONAL AERATOR <br />EXTENSION RISER <br />facilities, this process <br />involves a natural, SINGULAIR AERATOR <br />biological breakdown AERATOR MOUNTINGCASTING <br />of the organic matter in UNDERGROUND POWER <br />wastewater. SUPPLY CABLE TO SINGULAIR <br />CONTROL CENTER <br />PRETREATMENT <br />Wastewater enters the ACCESS COVER <br />pretreatment chamber <br />where anaerobic <br />bacterial action — - F <br />combines with the <br />effects of gravity to <br />precondition the waste INLET LINE j <br />before it flows into the <br />aeration chamber. Once t 1 t <br />in the aeration chamber, PRETREATMENT <br />CHAMBER e <br />aerobic bacteria utilize <br />the organic matter in = <br />the wastewater to AERATION <br />biologically convert the CHAMBER <br />waste into stable <br />substances. Following aeration, flow is transferred to the <br />clarification chamber where the effects of gravity settle out <br />biologically active material. The Bio -Static sludge return, <br />located in the clarification chamber, creates hydraulic <br />currents that gently transfer settled particles back to the <br />aeration chamber. As clarified liquids pass through <br />the Bio -Kinetic system, they are filtered, settled and <br />flow equalized. As a result, complete pretreatment, <br />aeration, clarification and final filtration are assured. The <br />Singulair system reliably protects you, your property and <br />the environment. <br />FEATURES AND ADVANTAGES <br />Singulair tanks are reinforced precast concrete, manufactured <br />by the licensed Norweco distributor. Internal walls and baffles <br />are cast -in-place to insure uniformity and maximum strength. <br />Risers and access covers are either heavy duty plastic or <br />concrete construction. All components within the system <br />that will contact the wastewater are constructed entirely of <br />molded plastic, stainless steel or rubber. <br />The Singulair aerator is powered by a 1725 RPM, 115 volt, <br />60 hertz, single-phase, fractional horsepower motor. It is <br />the only electrically powered component in the Singulair <br />system. The aerator <br />FRESH AIR VENT ASSEMBLY has been designed <br />OPTIONAL BLUE CRYSTAL specifically for use in the <br />CHLORINATION SYSTEM Singulair system. It <br />OPTIONAL BIO -NEUTRALIZER costs less to operate <br />DECHLORINATION SYSTEM <br />and consumes fewer <br />OPTIONAL BIO -KINETIC <br />SYSTEM EXTENSION kilo watt hours o f <br />LOW II LINE <br />PROFILE VIEW <br />SINGULAIR 500 GPD & 750 GPD <br />RISER electricity than most <br />'STEM major appliances. <br />KE I UKN number are displayed on <br />the control center cover. <br />All system controls and necessary owner information are <br />conveniently located at your fingertips. <br />Non-mechanical flow equalization and final filtration are <br />accomplished within the Singulair tank by the Bio -Kinetic <br />system. This revolutionary device is installed in the <br />clarification chamber and connected to the system outlet. <br />Optional chlorination and dechlorination may be included in <br />the Bio -Kinetic system if required. All Singulair components <br />work together to assure complete pretreatment, aeration, <br />clarification and final filtration. <br />Singulair aerators are <br />supplied with a Service <br />Pro control center with <br />MCD technology. The <br />EFFLUENT LINE <br />NEMA rated control <br />center contains a power <br />BIO -KINETIC <br />switch and time clock <br />SYSTEM <br />that control aerator <br />CLARIFICATION <br />CHAMBER <br />operation. The local <br />distributor's name, <br />BIO -STATIC SLUDGE <br />address and telephone <br />KE I UKN number are displayed on <br />the control center cover. <br />All system controls and necessary owner information are <br />conveniently located at your fingertips. <br />Non-mechanical flow equalization and final filtration are <br />accomplished within the Singulair tank by the Bio -Kinetic <br />system. This revolutionary device is installed in the <br />clarification chamber and connected to the system outlet. <br />Optional chlorination and dechlorination may be included in <br />the Bio -Kinetic system if required. All Singulair components <br />work together to assure complete pretreatment, aeration, <br />clarification and final filtration. <br />