My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
1331
>
2300 - Underground Storage Tank Program
>
PR0231332
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2024 2:20:04 PM
Creation date
12/4/2018 9:50:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231332
PE
2361
FACILITY_ID
FA0003961
FACILITY_NAME
LODI MUNI SERVICE CENTER
STREET_NUMBER
1331
Direction
S
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
03104050
CURRENT_STATUS
01
SITE_LOCATION
1331 S HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FOR' <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN (Page 2 of 2) <br /> VI.UNDER DISPENSER CONTAINMENT(UDC)MONITORING <br /> 1. UDC MONITORING IS PERFORMED USING TILE FOLLOWING METHOD 490-54, <br /> ® 1.CONTINUOUS ELECTRONIC MONITORING490-546 <br /> ❑ 2.FLOAT AND CI-LAIN ASSEMBLY ❑ 3.ELECTRONIC STAND-ALONE 490-54b <br /> ❑4.NO DISPENSERS — [199.OTIJER(Specify): <br /> - ------------- ---------------------------------------------------- <br /> PANEL MANUFACTURER: Veeder Root-- __— 490-55 MODEI.#:TLS 350 — 490-56 <br /> LEAK SENSOR MANUFACTURERVeeder loot 49057 MODEL#(S)0794380-208 490-58 <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS a.YES ❑b.NO 49&59 <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN a.YES ❑b.NO 490-60 <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. XX a.YI'S ❑b.NO 490-61 <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT TI IE DISPENSER. a.VM b N 490-61 <br /> 2.UDC CONSTRUCTION IS XRI.SINGLE-WALLED El 2.DOUBLE-WALLED 49(Y63 <br /> IF DOUBLE WALLED: - — -- ---- 490-64. 1 <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: [11.LI UID ❑2.PRESSURE ❑3.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE,AND VISUAL ALARMS ❑a.YES ❑b.N_O 490-64b 1 <br /> VII.PERIODIC SYSTEM TESTING <br /> ❑ 1. ELD TESTING: THIS FACILITY HAS BEEN NO'T'IFIED BY THE STATE WATER RESOURCES CONTROL. BOARD THAT ENHANCED 490-65. <br /> EAK DETECTION(I:I,D)MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED. 23 CCR§2644.1) -- <br /> )92.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTIIS 490-66 <br /> — — -- ------- — —— ---— <br /> 3.SPILL BUCKE'�S ARE TESTED ANNUALLY. --490 w <br /> VIII.RECORDKEEPING <br /> The following monitoring/maintenance records are kept for this facility: <br /> E&Alarm logs 490-68a ®Visual Inspection Records 490-68b ®Tank integrity testing results 490-68. <br /> E&SIR testing results(and supporting documentation records). 490-68d ® Tank gauging results(and supporting documentation records). 490.68. <br /> [XA"I'G Testing results(and supporting documentation records).490-68f ❑ Corrosion Protection 60-day logs 490-688 <br /> E&Equipment maintenance and calibration records. 490-6811 <br /> IX.TRAINING <br /> $]Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties. 490-69a <br /> RF,I�F.RENCE DOCUMENTS MAINTAINED A"f FACILITY(Check all that apply) <br /> g$ THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)490-69b <br /> JR OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)490-69c <br /> �$ CALIFORNIA UNDI RGROUND STORAGE TANK REGULATIONS 490-69d <br /> CALIFORNIA UNDERGROUND STORAGE TANK LAW 490-69. <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATIS'T'ICAL INVENTORY RECONCILIATION"490-69f <br /> ❑ SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"490.698 <br /> ❑ OTIIER(Specify):M69h,M69i <br /> I ❑This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> The"Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 days of hire.This <br /> training will include,but is not limited to,the following: <br /> :- Operation of the UST systems in a manner consistent with the facility's best management practices <br /> r The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> ➢ The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br /> Y Names of contact person(s)for emergencies and monitoring alarms.490-70 <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments here or indicate how many pages with additional information on specific monitoring procedures are attached to this plan.490-71 <br /> Tank over fill prevention unleaded tank #1, audible & visual alarm @90% <br /> Tank#2 unleaded audible & visual alarm @87%, Diesel tank mechanical flapper @ 95% <br /> XL PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that: 1)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br /> this plan occurs,2)all conditions that indicate a possible release are investigated,and 3)all monitoring records are maintained properly. <br /> The following person(s)are responsible for performing the monitoring and equipment maintenance <br /> NAMF Randy Laney 490-72 'nTLI Fleet Services Supervisor <br /> 490-73 <br /> NAME 490-74 TITLI- 490-75 <br /> The Designated Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator, and inform the owner/operator of any <br /> conditions that need follow-up action. <br /> XII.OWNER/OPERATOR SIGNATURE <br /> I CERTIFICATION:I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> APPMI T SIGNA'TUR' 490-76 DATE': 490-77 <br /> 'P C: ank O er .talar 2.Facdtt OwnenO.r for li 3.Authonred Rex ema�rve o(Owner <br /> APPLICANT NAME(print): 490-78 APPLICANT TITLE: 490-79 I <br /> Randy Laney Fleet Services Supervisor <br /> i <br /> UPCF UST-D(12/2007)3/4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.