My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
1331
>
2300 - Underground Storage Tank Program
>
PR0231332
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2024 2:20:04 PM
Creation date
12/4/2018 9:50:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231332
PE
2361
FACILITY_ID
FA0003961
FACILITY_NAME
LODI MUNI SERVICE CENTER
STREET_NUMBER
1331
Direction
S
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
03104050
CURRENT_STATUS
01
SITE_LOCATION
1331 S HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN (Page 2 of 2) <br /> VL UNDER DISPENSER CONTAINMENT(UDC)MONITORING <br /> 1. UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD 49 490-54a <br /> 0-Sdb <br /> a 1.CONTINUOUS ELECTRONIC MONITORING ❑2.FLOAT AND CHAIN ASSEMBLY ❑ 3-ELECTRONIC STAND-ALONE <br /> ❑4.NO DISPENSERS ❑99.OTHER(S i ): <br /> PANEL MANUFACTURER: P #: L✓ +35 d 490.56. <br /> LEAK SENSOR MANUFACTURER: D ( 490-57 I MODEL#(S):©-79Lj,3g4 —7�08 490-111 <br /> DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS J5 a.YES ❑b.NO 490-59 <br /> UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN it a.YES ❑b.NO 490.60 <br /> FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑b.NO 490.61 <br /> UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER. QL&YES ❑b.NO 490-62 <br /> 2.UDC CONSTRUCTION IS A].SINGLE-WALLED ❑2.DOUBLE-WALLED 490-63 <br /> IF DOUBLE WALLED: 490-64a <br /> UDC INTERSTITIAL SPACE IS MONITORED BY: 0 1.LIQUID El 2.PRESSURE 0 3.VACUUM <br /> A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑a.YES ❑b.NO 490-64b <br /> VII.PERIODIC SYSTEM TESTING <br /> ❑ 1. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 490-65. <br /> LEAK DETECTION(ELD)MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED.(23 CCR§2644.1 <br /> &2.SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 490-66 <br /> ----------------------- <br /> 3.SPILL BUCKETS ARE TESTED ANNUALLY. 490-67 <br /> VIII.RECORDKEEPING <br /> The following monitoring/maintenance records are kept for this facility: <br /> Alarm logs 490.69a Cff�Visual Inspection Records 490-68b j2r'fank integrity testing results 490-69c <br /> m <br /> R testing results(and supporting documentation records). 490-68d F1'Tank gauging results(and supporting documentation records). 490-68e <br /> TG Testing results(and supporting documentation records).490-Uf ❑ Corrosion Protection 60-day logs 490-6911 <br /> uipment maintenance and calibration records. 490.686 <br /> DL TRAINING <br /> Personnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job dudes. 490.69. <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) <br /> Oil-THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required)490-69b <br /> OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)490.690 <br /> CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490-69d <br /> {� CALIFORNIA UNDERGROUND STORAGE TANK LAW 490-6% <br /> ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION"490.69f <br /> ❑ SWRCB PUBLICATION:"UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS"490-698 <br /> ❑ OTHER(Specify):M69h,m69i <br /> ❑This facility has a"Designated UST Operator"who has passed the California UST System Operator Exam administered by the International Code Council(ICC). <br /> The"Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems annually,and within 30 days of hire.This <br /> training will include,but is not limited to,the following: Ld j-.3 'C C. a�Q r 1 IKchllib6`4 <br /> ➢ Operation of the UST systems in a manner consistent with the facility's best management practices <br /> ➢ The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br /> ➢ The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br /> D Names of contact person(s)for emergencies and monitoring alarms.49o-7o <br /> X. COMMENTS/ADDITIONAL INFORMATION <br /> Provide additional comments ere or indicate how many pages with additional information on specific monitoring procedures are attac ed tot s plan.490-71 y, <br /> �t'Ea�(C*1 tAn t"krs-r3e:i0 >,k- c 1j V 1 'L �-1� �4w:.vn 1 G) /^9 4` 1 } <br /> tl=-� 2 I,tv1lC+4+��3r /ju �t�l2 CORA, A 'yvr✓�� tj'7� 0te_%e <br /> tiv rw. bb d. <br /> I 1 i XL'PERSONNEL RESPONSIBILITIES <br /> The UST Owner/Operator is responsible for ensuring that:1)the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br /> this plan occurs,2)all conditions that indicate a possible release are investigated,and 3)all monitoring records are maintained properly. <br /> The follgVng person(s)are responsible for performing the monitoring and equipment * <br /> mei ten ce: <br /> NAME p � <br /> 490-72 TITLE ' — 1C_f 5 - Cl S� 490-73 <br /> NAME 490.74 TITLE 490-75 <br /> The Designated Operator shall perform a monthly visual inspection of the facility,provide a report to the owner/operator,and inform the owner/operator of any <br /> conditions that need follow-up action. <br /> XII.OWNER/OPERATOR SIGNATURE <br /> CER IFICATION:I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> AFL ANT SIGNA 490-76 DATE: 490-77 <br /> N L / rO2.Facility / r0- r ❑ th m b w r <br /> � <br /> AP CANT NAME(print): APPLICANT TITLE: <br /> 490-79��) p� 490.79 <br /> UPCF I:ST-D(12/2007)3/4 <br />