My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING_PRE 2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
1331
>
2300 - Underground Storage Tank Program
>
PR0231332
>
BILLING_PRE 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/24/2024 2:20:04 PM
Creation date
12/4/2018 9:50:33 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
PRE 2019
RECORD_ID
PR0231332
PE
2361
FACILITY_ID
FA0003961
FACILITY_NAME
LODI MUNI SERVICE CENTER
STREET_NUMBER
1331
Direction
S
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
03104050
CURRENT_STATUS
01
SITE_LOCATION
1331 S HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
IFIED PROGRAM CONSOLIDATED FORM I ( ✓A TANK: TA0133204 <br /> PR#: PR0231332 <br /> UNDERGROUND STORAGE TANKS -TANK E 1 (L� FAC#: FA0003961 <br /> / l (two pages per tank) <br /> TYPE OF ACTION ❑ I NEW SITE PERMIT ❑ 4 AMENDED PERMIT5 CHANGE OF INFORMATION Page 2 of9 <br /> (Check only item only) ❑ ❑ 6 TEMPORARY SITE CLOSURE <br /> ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-Por Jowl use only) (Specify reason-for local use only) ❑8 TANK REMOVED 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) FACILITY ID: PR#: 1 <br /> LODI MUNI SERVICE CENTER 3 FA000396 t PR0231332 nT1 I I <br /> LOCATION WITHIN SITE(Optional) 1331 S HAM Ln,LODI 431 <br /> PHONE <br /> I.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 4 432 TANK MANUF 433 COMPARTMENTALIZED TANK <br /> E]Yes E]No 434 <br /> TA0133204 PERKI If"Yes",complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACI NUMBER OF COMPARTMENTS <br /> 436 437 <br /> 10,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 436 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® <br /> I.MOTOR VEHICLE FUEL ® la.REGULAR UNLEADED ❑ 2.LEADED ❑ 5.JET FUEL <br /> (I f marked complete Petroleum Type) <br /> ❑ Ib.PREMIUM UNLEADED ❑ 3.DIESEL ❑ 6.AVIATION FUEL <br /> ❑ 2.NON-FUEL PETROLEUM ❑ Ic.MIDGRADE UNLEADED ❑4.GASOHOL ❑ 99.OTHER <br /> ❑ 3.CHEMICAL PRODUCT COMMON NAMEfrom Hazardous Materials Inventory rypage) 441 CAS#(from Hazardous Materials Inventory page) JJ' <br /> ❑ 4.HAZARDOUS WASTE <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> M.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 441 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑ 4.SINGLE WALL IN VAULT ❑99.OTHER <br /> TANK MATERIAL-primary tank ® 1.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> ANK MATERIAL-secondary tank ❑ 1.BARE STEEL ❑3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 445 <br /> Click one item only) ❑ 2.STAINLESS STEEL ❑4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑ 99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ RUBBER LINED 3EPDXY LINING 1. ❑ . 447 <br /> OR COATING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED <br /> (Check one item only) ❑ 2 ALKYD LINING ❑4 PHENOLIC LINING ® 6 UNLINED ❑99.OTHER <br /> (For local meanly) <br /> ) CORROSION E] I MANUFACTURING CATHODIC E] 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 446 DATE INSTALLED 449 <br /> );HTER <br /> 0ECTION IF APPLICABLE PROTECTION <br /> beck one item ody) ❑4 IMPRESSED CURRENT ❑ 99 OTHER <br /> C]2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLE450 TYPE(local use only) 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ❑ I SPILL CONTAINMENT ❑ 1 ALARM ❑ 3 FILL TUBE SHUT OFF VAL` <br /> ❑ 2DROP TUBE ❑ 2BALL ❑ 4EXEMPT <br /> ❑ 3 STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> / SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ 1 VISUAL(EXPOSED PORTION ONLY) E] 5 MANUAL TANK GAUGING(MTG) (Check one item only) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE ❑ 1 VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING <br /> (SIR)BIENNIAL TANK TESTING E]3 MANUAL MONITORING <br /> ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 1 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑No <br /> UPCF(12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.