My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
1331
>
2300 - Underground Storage Tank Program
>
PR0231332
>
COMPLIANCE INFO 2002 - 2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2019 2:07:54 PM
Creation date
12/4/2018 11:32:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2005
RECORD_ID
PR0231332
PE
2361
FACILITY_ID
FA0003961
FACILITY_NAME
LODI MUNI SERVICE CENTER
STREET_NUMBER
1331
Direction
S
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
03104050
CURRENT_STATUS
01
SITE_LOCATION
1331 S HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONI7. ORVNG SYSTEM CER'T'IFICATION <br /> For Use.Bv.=111,1urisdicnons ffithin the.State of California <br /> tuthorih°Cited Chapter 6.%, Hecilthacrd Safety-Code: Chapter 16. Division 3, "We 23, Caiilbrnia Code of Regulations <br /> Tlus form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be <br /> preparcd for each monitoring system controi oane' by the technician who performs the work. A copy of this form must be provided <br /> to the tank- system owner/operator. The ownerloperator must submit a cope of this fern to the local agency- regulating UST systems <br /> within 30 days of test date. <br /> A. General Informa 'on <br /> Facility Name: 1-0121 j J y Service Station No. <br /> Site Address: 1 L fl, /n L A/ City: b c Zip: <br /> Facility Contact Person: go 4 jj, Contact Phone No.: <br /> Make/Model of Monitoring System: Date of Testing/Sen'ic^• <br /> B. Inventory of Equipment 'Tested/Certified —`�t— <br /> Check thea ro cute boxes to:indicate ecific egu�menrt ins serviced: <br /> T ID: c a T ID: L,(v . (Z-4S- <br /> ank Gauging Probe: Model: Y 7 C'' Tank Gauging Probe: Model: <br /> �ular Space or Vault Sensor: Model: t� 3`C 4 z, Annular Space or Vault Sensor Model: T 5o Yt e <br /> ONping Sump/Trench Sensor(s): Model L,z i Y7 c.' SQ ping Sump/Trench Sensor(s): Model: r l4; <br /> ❑F" 1 Sump Sensor(s): Model: ❑F' Sump Sensor(s): Model: <br /> hanical Law Leak Detector. Model: eJ hanical Line Leak Detector. Model: K�- - O&C&C <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ❑Tank OverfilUHigh-level Sensor: Model: ❑Tank Overfill/Efigh-level Sensor. Model: <br /> ❑Other_ SVEifv and model in Section E on Page 2 ❑Other. S ecify and model in Section E on Page 2 <br /> Tank ID: <br /> Tank ID: 1,4 a,+2.�1 i_ <br /> ❑In-Tank Gauging Probe: Model: ❑ln-Tank Gauging Probe: Model: <br /> ❑Atmular Space or Vault Sensor: Model: []Annular Space or Vault Sensor Model-. 7 S G -4'2e <br /> EW�iptng Sump/Trench Sensor(s): Model: 6,�5`f S c Z.6� ❑Piping Sump/Trench Sensor(s): Model: <br /> ❑Fill Sump Sensor(s): Madel: ❑Fill Sump Sensor(s): Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector Model: ❑Electronic Line Leak Detector Model: <br /> ❑Tank Overfill/High-level Sensor: Model: ❑Tank Overfill/High-level Sensor: Nlodel- <br /> ❑Other. S cifi and model m Section E on Page 2 ❑Other. S . type and model in Section E on Pae 2 <br /> Di r ID: Dispenser ID: <br /> S ispenser Containment Sensors: pDispenser Cona'gtainment Sensor(s): Model: <br /> hear Va1ve(s). ❑ Shear Valve(s). <br /> []Dispenser Containment Float(s)and Chain(s) ❑D r Containment Float(s)and Chain(s) <br /> Dispenser ID: Y Dispenser ID: <br /> ❑Dispenser Containment Sensors: Model: ❑Dispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> L❑Dispenser Containment Float(s)and Cham(s) __ DDiTenser Containment rloat(s)and Chains} <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensors: Model: QDispenser Containment Sensor(s): Model: <br /> ❑ Shear Valve(s)- ❑ Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s) ❑Dispenser Containment Float(s)and Chain(s) <br /> =If the faciiity contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at this facility. <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br /> manufacturers' guidelines. Attached to this Certification is information te.g. manufacturers' checklists) necessary to verify that this <br /> information is correct and a Plot Plan showing the layout of monitoring equipp L For any equipmmee t capable of generating such <br /> reports, l have also attach cd a copy of the report: (check all th,4 apply). Svs[em set-up :..7 Alarm history report <br /> Technician Name(Print): Ed Stearns _ Siaaatvrc: <br /> Certification No-: : I — 11 il) License No-: <br /> m — — <br /> Testing Company dame: <br /> Champion Prevision Testing _ Phone No.: (916) 927,-15 <br /> n;m, <br />
The URL can be used to link to this page
Your browser does not support the video tag.