My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2002 - 2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAM
>
1331
>
2300 - Underground Storage Tank Program
>
PR0231332
>
COMPLIANCE INFO 2002 - 2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/12/2019 2:07:54 PM
Creation date
12/4/2018 11:32:20 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002 - 2005
RECORD_ID
PR0231332
PE
2361
FACILITY_ID
FA0003961
FACILITY_NAME
LODI MUNI SERVICE CENTER
STREET_NUMBER
1331
Direction
S
STREET_NAME
HAM
STREET_TYPE
LN
City
LODI
Zip
95240
APN
03104050
CURRENT_STATUS
01
SITE_LOCATION
1331 S HAM LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
349
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testinb/Servich. <br /> Software Version Installed: <br /> Complete the following chectdist: <br /> es ❑ No* L the audible alarm operational? <br /> Yes ❑ Nn* LS the visual alarm operational' <br /> es D No" f Were all sensors visually inspected, functionally tested, and confirmed operational? <br /> Yes ❑ No- Were all sensors installed at lowest DOittt of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> L Yes ❑ No* if alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> ❑ ?QUA operational? <br /> Er Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak.,fails to operate;or is electrically disconyected 7 If yes: which sensors itutiate � <br /> fpositive shut-down? (Check all that apply) Q"Sump/Trench Sensors; ErDispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/discoanection? ❑Yes; ❑No. <br /> 3'Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank- overfill warning device (i.e. no <br /> 13N,A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank- I <br /> fill points)and operatingproperly? If so, at what percent of tank-capacity does the alarm trigger? 'T�T— % <br /> ❑ Yes* No Was any monitoring equipment replaced? If yes,identify specific sensms,probes,or other equipment replac�'J <br /> and list the manufacturer name and model for all renlacement parts in Section E,below. <br /> Yes* ❑ No Was liquid found inside any secondary containment systems designed as dry systems? (Check all tha:apply) <br /> Product; ❑Water, If yes,describe causes in Section E.below. <br /> uf Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if a pplicable <br /> 0 Yes ❑ No* I Is all monitoring equipment operational per manufacturer's specifications? <br /> * In Section E below.describe how and when these deficiencies were or will he corrected. <br /> E. Comments: 1 J ATL-L r h \i�s vt l qmf ` 2- l V R�'O�"O J N <br /> 0 P�gC cD I Lyr,f . <br /> page 2 or 3 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.