Laserfiche WebLink
Table 4. Laboratory Test Results - Hydrocarbon Compounds 2/ (Continued) <br /> 1/ Asterisk(*)denotes monitoring events which were conducted by Condor Earth Technologies,Inc. Well casing and ground-water elevations are listed in feet,and <br /> referenced to Mean Sea Level(MSL). <br /> 2/ Ground-water samples were analyzed by Sequoia Analytical, 819 Striker Avenue, Suite 8, Sacramento,California 95834. "NA"denotes that an analysis was not <br /> performed for that chemical parameter. "ND"denotes the chemical parameter was not detected during analysis. "NL"denotes a parameter that is not listed by the State. <br /> 3/ Detection limits for nitrogen compounds varied between analytical runs. However,a single(conservative)detection limit is shown at the top of each column for <br /> convenience. Actual,run-specific,detection limits for 1,2-DCP and other volatile organic compounds are shown in brackets behind the reported analytical result. <br /> Chemical compounds are abbreviated as follows: 1,2-DCP(1,2-dichloropropane),PCE(tetrachloroethene),DBCM(dibromochloromethane),CF(chloroform),BDCM <br /> (bromodichloromethane), DINO(Dinoseb, or(2-sec-butyl-4,6'-dinitrophenol),2,4-D((2,4-dichlorophenoxy)acetic acid)),2,4-DB(4-(2,4-dichlorophenoxy)butyric acid), <br /> • <br /> DP(Dichloroprop,or 2-(2,3-dichlorophenoxy)propionic acid), MC(methylene chloride,aka chloromethane). <br /> 4/ Laboratory nitrate(NO,)test results were converted to nitrogen-as-nitrate(N-NO,)values by multiplying each reported result by 0.225. Molecular N-ratios are based on <br /> atomic weights. Under normal soil conditions,total-nitrogen(N)is approximately equal to the sum of TKN and N-NO3_ <br /> 5/ Statewide water quality goals have been established for several specific compounds by the SWRCB. Values shown include primary and secondary State and federal <br /> maximum concentration levels(MCL). <br /> 6/ Ground water samples from MW-2 and MW-6 were tested for carbamate pesticides, including Propoxur,by EPA Method 632. No pesticides were detected. <br /> 7/ Samples collected by Central Valley Region, RWQCB, as splits from Sierra-Pacific samples, same date, same time, for comparison of a) <br /> laboratories utilized, and b) sampling with submersible pump versus sampling with disposable bailer for volatile organic analysis (VOA). <br /> 8/ These 40-m1 VOA samples were collected with disposable bailers. All other VOA samples collected with submersible pump. <br /> • <br /> Siena-Pacific Groundwater Consultants, Ibrc. <br />