Laserfiche WebLink
Engineering PHYSICAL DATA <br /> Merchandiser Drip Pipe(in.) I Ih <br /> Merchandiser Liquid Line(in.) 31s <br /> Plan Views Merchandiser Suction Line(in.) 518 <br /> Meat & Delicatessen <br /> Flat Hinged Glass <br /> Models <br /> 05-2011 Dimensions shown as In.and(mm). <br /> A <br /> D <br /> C <br /> SMGT 49 45 a/a 043 <br /> 9 <br /> SMGT (1092) 23/4(70)(1153) (tosz) 1718(47) B 5 1/2(140) <br /> 32 1A <br /> 7 7 24 518 r L 4 3/4(120) r`r t Note•1 T 27 (810) <br /> 1 1 I I i 8 (888) <br /> I I Refrigeration Outle -r(� 331/8 <br /> �----- I I 283/4 I I w,�sa r I--�-- (841) <br /> }�!AWaste Outlet Ll (730) } " I 44 F/e <br /> Waste Outlet <br /> Splashguard <br /> FRONT 12 1/8(307) <br /> 4 it 6 it 8 ft 12 ft <br /> General <br /> (A) Case Length 481/4(1226) 721/4(1835) 96 3/8(2448) 144 1/2(3670) <br /> Maximum O/S dimension of case back to front 44 7/s(1140) 44 7/s(1140) 44 7/s(1140) 44 7/8(1140) <br /> (Note:Includes bumper) <br /> Back of case to front of splashguard 331/9(841) 331/8(841) 33 I/s(841) 331/8(841) <br /> Center of rear legs to center of front legs 231/2(598) 23 Ih(598) 23 42(598) 231/2(598) <br /> Each End and Partition adds 1 Ih in.(38 turn)to the length of the lineup. <br /> Electrical Service <br /> (B) RH end of case to Electrical raceway right edge 37/s(98) 3 7/a(98) 37/s(98) 31/8(98) <br /> (C) RH end of case to Electrical raceway left edge 44 I/s(1121) 40 1/2(1029) 441/8(1121) 44 I/s(1121) <br /> Back of case to center of knockout 1 71s(47) 17/8(47) l7/s(47) 1 7/a(47) <br /> *Electrical Field Wiring Connection Point <br /> Waste Outlet <br /> (D) RH End of case to the center of LH waste outlet 361/4(921) 601/4(1530) 84 3/8(2143) 132 Ih(3366) <br /> RH End of case to the center of RH waste outlet 121/8(307) 121/o(307) 121/s(307) 12 11s(307) <br /> Back O/S of case to center of waste outlets 321/4(819) 321/4(819) 321/4(819) 321/4(819) <br /> Schedule 40 PVC drip pipe 1 1/4(32) 1 1/4(32) 11/4(32) 11/4(32) <br /> " Field installed water seal outlets, tees, and connectors are shipped with the merchandiser. <br /> Refrigeration Outlet <br /> Back of case to center of refrigeration outlet 27(686) 27(686) 27(686) 27(686) <br /> RH end of case to center of refrigeration outlet 8(203) 8(203) 8(203) 8(203) <br /> Outside diameter of the liquid line 3/8(9.5) 3/8(9.5) 3/S(9.5) 318(9.5) <br /> Outside diameter of the suction line 31s(16) 518(16) 51s(16) S/s(16) <br /> 2 of 10 U.S.&CANADA 1-800-922-1919•MEXICO 1-800-890-2900•WWW.HUSSMANN.COM SMGT Technical Data Sheet <br />