My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS 3
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
ELEVENTH
>
1801
>
1600 - Food Program
>
PR0518813
>
WORK PLANS 3
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 10:20:02 AM
Creation date
12/7/2018 3:25:00 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
FileName_PostFix
3
RECORD_ID
PR0518813
PE
1619
FACILITY_ID
FA0022704
FACILITY_NAME
SAFEWAY #2600
STREET_NUMBER
1801
Direction
W
STREET_NAME
ELEVENTH
STREET_TYPE
ST
City
TRACY
Zip
95376
APN
23217024
CURRENT_STATUS
01
SITE_LOCATION
1801 W ELEVENTH ST
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS\E\ELEVENTH\1801\PR0518813\PLANS 3.PDF
QuestysFileName
PLANS 3
QuestysRecordDate
6/29/2018 9:12:59 PM
QuestysRecordID
3932158
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND GENERAL NOTES <br /> ® EQUIPMENT NUMBER. 1. INSTALL ALL WORK IN ACCORDANCE WITH ALL CODES AND AS PER MANUFACTURER'S WRITTEN INSTRUCTIONS.MAINTAIN <br /> SEE EQUIPMENT SCHEDULE. MANUFACTURER'S SPECIFIED CLEARANCES FOR ALL EQUIPMENT. p <br /> M <br /> 2. CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS SHOWN ON DRAWINGS AND TO REPORT ANY DISCREPANCIES TO y <br /> ARCHITECT AND/OR SAFEWAY REPRESENTATIVE. V] <br /> GENERAL ELECTRICAL NOTES <br /> 1. ALL WIRING SHALL BE RUN IN METALLIC CONDUIT.CONCEAL IN WALLS&CEILINGS IN FINISHED AREAS,MC CABLE MAY BE RUN <br /> CONCEALED ABOVE CEILINGS OR IN WALLS WHERE NOT SUBJECT TO PHYSICAL DAMAGE. a ,_..i <br /> 2. ALL EQUIPMENT SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PARALLEL&PERPENDICULAR TO BUILDING STRUCTURE. ¢ ~ ppp <br /> O 3. MINIMUM CONDUIT SIZE SHALL BE 3/4",UNLESS NOTED OTHERWISE.MINIMUM WIRE SIZE SHALL BE#12 AWG THHNITHWN TYPE,UNLESS VA <br /> NOTED OTHERWISE.ALL WIRING TO BE COPPER.ALL WIRE SIZE SHOWN ON THE ELECTRICAL EQUIPMENT NOTES ARE INTENDED TO BE O till In w• <br /> THE MINIMUM ACCEPTABLE WIRE SIZE. E"iX <br /> O C U <br /> 4. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE CURRENT ELECTRICAL CODE,THE LATEST STATE CODES,AND LOCAL CODES. a w <br /> 5. ALL ELECTRICAL EQUIPMENT,INCLUDING,BUT NOT LIMITED TO CONDUIT,WIRE,BOXES,AND FITTINGS,SHALL BE NEW AND FREE OF <br /> F <br /> DEFECTS,SHALL BEAR THE UL LABEL,AND SHALL MEET NEMA AND ANSI STANDARDS. <br /> 6. ALL WORK AND MATERIALS SHALL BE GUARANTEED FREE FROM DEFECTS FOR A MINIMUM PERIOD OF ONE YEAR UNLESS NOTED <br /> OTHERWISE. <br /> 7. THE COLORS OF ALL RECEPTACLES AND DEVICE PLATES SHALL MATCH EXISTING. <br /> 8. CONTRACTOR TO VERIFY THAT NO PIPING,DUCTWORK,OR ANY OTHER MECHANICALIPLUMBING EQUIPMENT IS RUN DIRECTLY ABOVE <br /> ELECTRICAL PANELS. <br /> 9. WHERE EXISTING EQUIPMENT IS SHOWN TO BE RELOCATED,ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUIT,JUNCTION <br /> BOXES,CABLE,&ACCESSORIES AS REQUIRED TO REVISE EXISTING CIRCUITING TO ACCOMMODATE NEW LOCATION OF EQUIPMENT 4_1 <br /> 5 • .'i <br /> 10. ELECTRICAL CONTRACTOR TO VERIFY IN THE FIELD ALL RECEPTACLES&JUNCTION BOXES TO BE REUSED OR RELOCATED lz <br /> \- ACCORDINGLY WITH MODIFIED RETAIL AREA LAYOUT. ANY FLOOR RECEPTACLE OR JUNCTION BOX NOT IN USE SHOULD BE REMOVED, <br /> EXISTING N ` U <br /> 0� AND FLOOR SHOULD BE PATCHED FLUSH WITH MATERIAL TO MATCH EXISTING. �/ <br /> HOOD <br /> It VERIFY ALL WORK TO BE DONE WITH SAFEWAY REPRESENTATIVE BEFORE PROCEEDING. <br /> 0 <br /> 12. ELECTRICAL CONTRACTOR IS TO PROVIDE GFI PROTECTION FOR EQUIPMENT RECEPTACLES PER THE CURRENT ELECTRIC CODE. 5� <br /> 13. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY THE EXISTING ELECTRICAL PANELS TO DETERMINE THE PROPER LOCATION FOR THE <br /> NEW CIRCUITS.VERIFICATION SHALL INCLUDE MONITORING OF THE ELECTRICAL LOAD WITHIN THE PANEL,UNDER FULL LOAD,TO <br /> CONFIRM SPARE CAPACITY AS WELL AS THE PHYSICAL SPACE TO ADD BREAKERS.RELOCATE EXISTING BREAKERS AS NECESSARY OR <br /> / \ REQUIRED TO FIND THE CORRECT SPACE,PROVIDE MONITORING RESULTS TO THE SAFEWAY PROJECT MANAGER,AND TO THE <br /> 2 0 <br /> ARCHITECT/ENGINEER. <br /> oO� CD O ELECTRICAL EQUIPMENT NOTES w <br /> r. Z o <br /> 1 WHERE BOXES,EPOW RPOLES, <br /> GIPMENT IS SHOWN TO BE RELOCATED,CABLE AND ACCESSORIES AS REQUIRED TO OREVIISE EXISTING CIRCUITINGDL CONTRACTOR SHALL PROVIDE LCIJUNCTION <br /> G A ACCOMMODATE ENEW 0 <br /> LOCATION OF EQUIPMENT. Ix 00 <br /> / z 00 <br /> O 2. ELECTRICAL CONTRACTOR SHALL PROVIDE FOR NEW 6' REFRIGERATED WORK TABLE AN NEW OUTLET NEMA 5-15R WITH 2#12, O O 00 <br /> OD 1#12G,3/4"C TO EXISTING PANEL.CONNECT TO AN EXISTING SPARE 20A/1P BREAKER FOR CIRCUIT PROTECTION.PROVIDE TYPED, U } J <br /> UPDATED SCHEDULE FOR ENTIRE PANEL AFTER INSTALLATION. Z0 Q <br /> O //� 3. ELECTRICAL CONTRACTOR SHALL PROVIDE FOR NEW RICE WARMER AN NEW GFI OUTLET NEMA 6-20R WITH 2#12, 1#12G,3/4"C TOZ U U <br /> i� 4 EXISTING PANEL. CONNECT TO AN EXISTING SPARE 20A/2P BREAKER FOR CIRCUIT PROTECTION, PROVIDE TYPED, UPDATEDs Z Z w <br /> SCHEDULE FOR ENTIRE PANEL AFTER INSTALLATION. O J 0 <br /> 3 <br /> 4. ELECTRICAL CONTRACTOR SHALL PROVIDE FOR NEW 8' HOT FOOD CASE AN OUTLET NEMA L21-30P WITH 3#10, 1#10G, 3/4"C TO W m Z V <br /> EXISTING PANEL. CONNECT TO AN EXISTING SPARE 30A/3P BREAKER FOR CIRCUIT PROTECTION. PROVIDE TYPED UPDATED Q <br /> SCHEDULE FOR ENTIRE PANEL AFTER INSTALLATION. Z W fA <br /> o ELECTRICAL EQUIPMENT SCHEDULE Q <br /> _._ O O DESCRIPTION AMPS VOLTS PHASE CYCLE PLUG RECEPT LOCATION BRSIZEER $ J <br /> O 6'REFRIGERATED 7.5 120 1 60 HZ 5-15P 5.15R FLOOR 20A/1P Q <br /> WORK TABLE % W <br /> OO RICE WARMER 15 208 1 60 HZ 6.20P 6.20R WALL 20A/2P a O 0 <br /> O 1 O cli <br /> R L21 <br /> H <br /> 22 208 3 60 Z L21-30P .30FLOOR 30A13P w <br /> 8'HOT FOOD CASE N <br /> z O <br /> Z <br /> 1sEl <br /> "I WZ <br /> w J <br /> Z Q m <br /> w co <br /> � L H <br /> _ 0 Z <br /> U <br /> g H w � U w <br /> a Z Y >� W <br /> ----- �o o F Q > U <br /> ° EQUIPMENT SCHEDULE 0 _ W <br /> o W z g F <br /> a � �� ~ w <br /> E a U) <br /> e <br /> ° EQ# STATUS DESCRIPTION MANUFACTURER MODEL REMARKS g <br /> O <br /> OO CD NEW 6'REFRIGERATED WORKTABLE TRAULSEN UHT72-LR SEE ELEC EQUIP NOTE 2 � At <br /> NEW 3-WOK RANGE IMPERIAL ICRA-3 SA CONNECT TO EXISTING GAS AND COLD WATER LINESSERVING DEMOLISHED WOK RANGE 6 <br /> wo O 0 NEW RICE WARMER TOWN 5715555 SEE ELEC EQUIP NOTE 3 "'o <br /> 0 <br /> NEW 3'x4'S.S.WORKTABLE WIN-HOLT - <br /> O0 NEW 8'HOT FOOD CASE HENNY PENNY HMR 107 SEE ELEC EQUIP NOTE 4 <br /> O < 111& <br /> .E m <br /> b W 0 <br /> � N <br /> -- - O� <br /> O q � <br /> O O O k <br /> O O 00 U) W <br /> �a <br /> 0 <br /> koj_ <br /> °uj <br /> O <br /> O o0 <br /> El <br /> B <br /> a Z w <br /> W O Q Z y <br /> 01 0 <br /> LLI <br /> 00 <br /> [3 ® 0 d co <br /> N o g U m <br /> ® 0 2600 <br /> TRACY, CA <br /> ® O8 AREA OF WORK SAFEWAY <br /> 1 EQUIPMENT PLAN � � <br /> Al Cy <br /> SCALE: 1/4"=1'-0" <br /> ONEE nAl <br /> KEY PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.