Laserfiche WebLink
i <br /> List OF Abbreviations Viuh'K�y hv4 p <br /> NTS <br /> A AIC AIR CONDITION E EL ELEVATION L LAV LAVATORY S SC SOLID CORE 1 <br /> , i <br /> AB ANCHOR BOLT ELEC ELECTRICAL LBL LABEL SCHED SCHEDULE Y <br /> -1 <br /> ACT ACOUSTICAL CEILING TILE ELEV ELEVATOR LBS POUNDS SCP SCUPPER ; „ ! _'`% I <br /> / J , <br /> AD ADJUSTABLE,ADJACENT EMER EMERGENCY LF LINEAR FEET SD SOAP DISPENSER N O <br /> AFF ABOVE REF FINISHED EQ EQUAL LT WT LIGHT WEIGHT SEAL SEALANT M <br /> FLOOR(SLAB) EQUIP EQUIPMENT SECT SECTION <br /> AHU AIR HANDLER UNIT ESC ESCALATOR M MAS MASONRY SF SQUARE FEET <br /> ALT ALTERNATE EWC ELECTRIC MAX MAXIMUM SHT SHEET <br /> ALUM ALUMINUM WATER COOLER MECH MECHANICAL SIM SIMILAR LO 4e� <br /> ANOD ANODIZED EXIST EXISTING MFR MANUFACTURER SPEC SPECIFICATION �C_ r1 41� <br /> APPROX APPROXIMATE EXP EXPANSION MH MANHOLE SS STAINLESS STEEL, <br /> ARCH ARCHITECT EXT EXTERIOR MIN MINIMUM SERVICE SINK <br /> AUTO AUTOMATIC MIN MINIMUM,MINUTE STD STANDARD _ o <br /> F FACP FIRE ALARM MISC MISCELLANEOUS STI. STEEL � i �� ►� pq ix, <br /> B BO BOTTOM OF CONTROL PANEL MLDG MOLDING STOR STORAGEkn <br /> \ <br /> BD BOARD FD FLOOR DRAIN MO MASONRY OPENING STRUC STRUCTURAL <br /> BLDG BUILDING FDN FOUNDATION MR MOISTURE RESISTANT SUSP SUSPENDED , <br /> BM BEAM FIN FINISHED MTD MOUNTED SY SQUARE YARD <br /> BRG BEARING FLR FLOOR MTL METAL <br /> BTM BOTTOM FR FIRE RESISTANT MUL MULLION T T TREAD 4 <br /> BUR BUILT UP ROOF FR-S FIRE-RETARDANT T&G TONGUE&GROOVE <br /> WOOD TREATMENT N NIC NOT IN CONTRACT TBL TABLE \, �'Z 7 <br /> PROJECT LOCATION <br /> C CB CATCH BASIN FT FEET,FOOT NOM NOMINAL TELE TELEPHONEI '` _ <br /> 1 <br /> GG CORNER GUARD FTG FOOTING NTS NOT TO SCALE TEMP TEMPERED 'S = . ..,;� Ir,; v� �- to r�� it 11 � /�600 <br /> Cl CAST IRON FURR FURRING THK THICK G <br /> CJ CONTROL JOINT FUT FUTURE 0 OC ON CENTER TILT TOILET <br /> v.�.. \� I <br /> II <br /> CL CENTER LINE OD OUTSIDE DIAMETER TO TOP OF c/ <br /> 3 1 W� �t 11th3treeCLG CEILING G GA GAUGE OPP OPPOSITE TPD TOILET PAPER CLO CLOSET GAL GALLON OVFL OVERFLOW DISPENSER <br /> CLR CLEAR GALV GALVANIZED TS TUBE.STEEL <br /> CMU CONCRETE GB GRAB BAR P PL PLATE TV TELEVISION <br /> MASONRY UNIT GC GENERAL CONTRACTOR PLAM PLASTIC LAMINATE TYP TYPICAL <br /> CO CLEAN OUT GYP GYPSUM PLAS PLASTER Tracy <br /> COL COLUMN PLBG PLUMBING U LION UNLESS OTHERS <br /> CONC CONCRETE H HB HOSE BIBB PLWD PLYWOOD WISE NOTED <br /> CONST CONSTRUCTION HC HOLLOW CORE PNL PANEL UTIL UTILITY l` <br /> CONT CONTINUOUS HDW HARDWARE PR PAIR rJ f o rn I a <br /> CONTR CONTRACTOR HM HOLLOW METAL PREFAB PREFABRICATED V VB VINYL BASE <br /> CORR CORRIDOR HORIZ HORIZONTAL PT POINT VCT VINYL COMPOSITE TILE <br /> CT CERAMIC TILE HR HOUR PT PRESSURE TREATED VERT VERTICAL 1`I <br /> CTR CENTER HT HEIGHT PTD PAPER TOWEL DISPENSER VEST VESTIBULE <br /> CU CONDENSING UNIT HTG HEATING PVC POLY VINYL CHLORIDE VIF VERIFY IN FIELD <br /> CW COLD WATER HVAC HEATING,VENTILATING VTR VENT THRU ROOF -`- <br /> &AIR CONDITIONING Q QT QUARRY TILE VWC VINYL WALL COVERING DRAWING NDEX <br /> D DBL DOUBLE HW HOT WATER <br /> DEPT DEPARTMENT R R RADIUS,RISER, W W WIDTH Q N <br /> DET DETAIL [ ID INSIDE DIAMETER THERMAL RESISTANCE WI WITH ARCHITECTURAL ELECTMCAL PLIMBING . <br /> DF DRINKING FOUNTAIN IN INCH RD ROOF DRAIN WIO WITHOUT € J <br /> DIA DIAMETER INCL INCLUDING RECP RECEPTACLE WC WATER CLOSET ELECTRCIAL GENERAL PLUMBING GENERAL J o�p <br /> DIM DIMENSION INSUL INSULATION REF REFERENCE WD WOOD AO COVER SHEET E1 PO L <br /> DISP DISPENSER NT INTERIOR REFR REFRIGERATOR WH WATER HEATER INFORMATION INFORMATION <br /> DN DOWN INV INVERT REG REGLET WP WATERPROOF SANITARY,WASTE AND ��° W <br /> AD1 DEMOLITION PLAN E2' LIGHTING PLANS P1 <br /> DS DOWNSPOUT REINF REINFORCEMENT WT WEIGHT III DOMESTIC WATER PLANS � c� � U :r <br /> DWG DRAWING J JAN JANITOR REQ REQUIRED WWF WELDED WIRE FABRIC FURNITURE,FIXTURES,AND <br /> JB JUNCTION BOX REV REVISION WWM WELDED WIRE METAL Al E3 POWER PLANS P2 LOAD KING PACKAGE <br /> EQUIPMENT PLAN Uj Z <br /> E EA EACH JT JOINT RM ROOM I Lj 0 <br /> EB EXPANSION BOLT RNID ROUND Y YD YARD ELECTRICAL SINGLE LINE z ~ <br /> EIFS EXTERIOR INSULATING L L LENGTH RO ROUGH OPENING A2 LIGHTING I REFLECTED CEILING PLAN E4 P3 LOAD KING PACKAGE , 1 <br /> FINISH SYSTEM LAM LAMINATE RTU ROOF TOP UNIT _-_ -- -- DIAGRAM ¢ LL F- < <br /> EJ EXPANSION JOINT KIOSK ELEVATIONS&INTERIOR Q <br /> A3 E5 LOAD KING PACKAGE P4 LOAD KING PACKAGE � H � W <br /> ELEVATIONS <br /> U <br /> Code Information <br /> Legend o - <br /> 000 C <br /> Building: California Building Code 2013 Edition I 71 ❑ <br /> GRID DESIGNATION � � BUILDING SECTION Fire: California Fire Code 2013 <br /> A301-2 A301-2 Plumbing: California Plumbing Code 2013 Edition - _ _ <br /> Mechanical: California Mechanical Code 2013 Edition o <br /> SHEET NUMBER SECTION NUMBER ❑ ❑ ❑ ❑ ❑ I— <br /> ❑ Electrical: California Electrical Code 2013 Edition --- _- _ _ ❑ ❑ p ❑ mI W �- <br /> 102 ROOM NUMBER ❑ _ �� <br /> ADA, Americans with disabilities Act-2009 ❑ L U ❑-I <br /> LU <br /> 1D2A <br /> DOOR NUMBER � WALL SECTION -,- ----- � `` " ' " � x � � ; <br /> r <br /> A302-3 <br /> r <br /> E co <br /> SHEET NUMBER SECTION NUMBER f . I - -, 1 - - —^ �°-_ - LO <br /> - _- - _ = ------ - _ - _ _ -_ _ _ --- (Y T <br /> 2 WINDOW TYPE <br /> Contact c <br /> O `�����aC� In�o�rn���o©�� � w YUj <br /> F-1 77 <br /> OWNER: GOLUB CORPORATION -- - I Uj <br /> z m � W y -� <br /> ® STOREFRONT TYPE A5I}1-6 SECTION DETAIL 0 �� ! _ _ O� I v <br /> 461 NOTT STREET 4i I J <br /> 11 1 Liv <br /> SCHENECTADY,NY 12308 <br /> � � W Q � C-:) H <br /> 3 WALL TYPE SHEET NUMBER DETAIL NUMBER j {� � _ <br /> Cr <br /> CONTACT, CHET PENNACCHIA,DIRECTOR OF CONSTRUCTION <br /> PHONE: (518)379-1549 <br /> NATHAN ALOIS,JOB CAPTAIN <br /> 0 5 KEY NOTE A8 88-8B DETAIL REFERENCE - ,� <br /> - - ------ <br /> FAX: <br /> (518)379-1558 •- .....__ ,..,., I :-•. .:-•.• ,•� ,'"� <br /> FAX, (518)379-3314 I � � <br /> .. <br /> SHEET NUMBER DETAIL NUMBER O - = ~ "'Q <br /> 6 REVISION NUMBER - - o` oQ <br /> H CS 0 <br /> ARCHITECT: JAMES E.DOWNS ❑ _ <br /> 1925 PROSPECT AVENUE _ L ^` r • - JI �� �, o 4 <br /> ORLANDO,FL 32814 O w w <br /> OL TO SOMETHING xxrELEVATIONS TAGS `'' w o <br /> a,2� � CONTACT: BARBARA HOGAN — <br /> i <br /> EXTERIOR ELEVATION <br /> MARKERS <br /> PHONE: 215 641-4830 EXT 5215 �'' <br /> ( ) I - 2 c� <br /> SPOT ELEVATION TAG SHEET NUMBER ELEVATION NUMBER O _ �/ � ` <br /> '+ PLUMBING JOSEPH KEENE,P.E. - <br /> ENGINEER: 1925 PROSPECTAVENUE <br /> ORLANDO,FL 32814 � <br /> L�� 8 o c_o <br /> _- Uj <br /> FI = j 1. ¢ o <br /> INTERIOR ELEVATION CONTACT: JOSEPH KEENE - I l j0 <br /> 4 A401 2 MARKERS PHONE: (407)661-9100 O ; o jl _11 ccc <br /> NORTH ARROW - I O � _ 00 <br /> NO O 9 <br /> SHEET NUMBER ELEVATION NUMBER ELECTRICAL JAISON MORAS O �� - <br /> 3 1925 PROSPECT AVENUE V - --- / <br /> ORLANDO,FL 32814 __ „ ;' g <br /> w W <br /> CONTACT: JAISON MORAS _ / � � Q w <br /> I <br /> LU <br /> PHONE: (407)661-9100 O ,- ' `7 V / _f� w O <br /> / ` ` U_ <br /> (9 n a ra I N otes A� <br /> O uJ <br /> 1. ALL WORK WILL COMPLY WITH LOCAL,STATE,AND NATIONAL CODES Scope Work. °o <br /> RELATED TO THIS PROJECT. - - <br /> _ o --o <br /> 2. THE WRITTEN DIMENSIONS PREVAIL ON THE CONSTRUCTION DOCUMENTS, - o o , �0 <br /> DO NOT SCALE THESE DRAWINGS,CONTRACTOR TO VERIFY ALL moo: 42 <br /> DIMENSIONS AND CONDITIONS IN THE FIELD. IF ANY DISCREPANCY <br /> 1. THE SCOPE IS LIMITED TO STARBUCKS AND AFFECTED UTILITIES - - -- - - <br /> g <br /> O <br /> z <br /> OCCURS,THE CONTRACTOR 1S REQUIRED TO NOTIFY THE ARCHITECT IN 2. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE EXTERIOR OF SAFEWAY STORE#260D � � o <br /> WRITING BEFORE PROCEEDING WITH ANY WORK AFFECTED BY THE EXCEPT FOR A STARBUCKS SIGN LOCATED ON THE EXTERIOR STOREFRONT , / j � N z <br /> DISCREPANCY. r i �t <br /> 3. THE SCOPE DOES NOT INCLUDE ANY WORK ON THE FOUNDATIONS,COLUMNS,BEAMS; w N ¢ m <br /> 3. CONTRACTORS TO SECURE ALL PERMITS AND REQUIRED INSPECTIONS GIRDERS,JOISTS OR TRUSSES. THE SCOPE DOES NOT INCLUDE ANY STRUCTURAL WORK ON CL D D U <br /> NECESSARY TO OBTAIN A CERTIFICATE OF OCCUPANCY. ANY OF THE EXISTING EXTERIOR WALLS. - <br /> - --- <br /> 4. CONTRACTORS ARE TO PROVIDE ALL TEMPORARY UTILITIES AND 4. THE SCOPE INCLUDES PROVIDING NEW PLUMBING TO SERVE THE NEW KIOSK a Ll r �- !� <br /> INFRASTRUCTURE REQUIRED TO PERFORM THE WORK,INCLUDING FIRE l J� <br /> x <br /> PROTECTION AS REQUIRED DURING CONSTRUCTION. 5. THE SCOPE DOES NOT INCLUDE ANY WORK RELATED TO GREASE OR GAS. ° i ❑ 0 _ �� 1 Jl <br /> 6. THE SCOPE DOES NOT INCLUDE ANY WORK TO THE BUILDING TRANSFORMER,SECONDARY ° - r - - '' CY, CA <br /> 5. PRODUCTS SPECIFIED OR OTHERWISE INDICATED IN THE CONTRACT -- -- -- - - _ -_ _. _- � - <br /> DOCUMENTS SHALL NOT BE SUBSTITUTED WITHOUT PRIOR WRITTEN CONDUIT,SECONDARY WIRE,OR MAIN DISCONNECT. <br /> APPROVAL FROM STARBUCKS - --- _ �I <br /> 7. THE SCOPE INCLUDES PROVIDING A NEW ELECTRICAL SERVICE FOR THE KIOSK ❑ ��I1 I� � <br /> 6. THIS CONTRACTOR SHALL COORDINATE ALL TRADES REQUIRED TO 8. THE SCOPE INCLUDES PROVIDING NEW POWER AND LIGHTING AS SHOWN. \\� Imo'! SAFEWAY <br /> /a <br /> EQ <br /> COMPLETE THIS PROJECT AS REQUIRED TO ACTIVATE THE USE OF THE 4 -T --- - <br /> FACILITY AS PLANNED, <br /> ����j nrr r PROJECT LOCATION <br /> 7. THE CONTRACTOR SHALL HAVE ONS FOR <br /> ALL EQUIPMENT AND APPLIANCES ON SITE AT TIME OF INSPECTION.ON. ocaq- l4 co)n P a u� <br /> A 0 <br /> NTS <br />