My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOWER SACRAMENTO
>
1613
>
1600 - Food Program
>
PR0541351
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/7/2022 2:09:13 PM
Creation date
12/7/2018 7:23:05 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0541351
PE
1625
FACILITY_ID
FA0023696
FACILITY_NAME
MCDONALDS 36681
STREET_NUMBER
1613
Direction
S
STREET_NAME
LOWER SACRAMENTO
STREET_TYPE
RD
City
LODI
Zip
95242
APN
04931058
CURRENT_STATUS
01
SITE_LOCATION
1613 S LOWER SACRAMENTO RD
P_LOCATION
02
QC Status
Approved
Scanner
SJGOV\jcastaneda
Supplemental fields
FilePath
\MIGRATIONS\L\LOWER SACRAMENTO\1613\PR0541351\PLANS.PDF
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I m <br /> RESTROOM NOTES <br /> • NO WORK IN THIS AREA; <br /> EXISTING TO REMAIN, U.N.O. <br /> I <br /> I <br /> - - z <br /> 0 <br /> I <br /> \�Wo o s // I <br /> a-]] L <br /> I I I I I <br /> � - -1I <br /> II II <br /> FREEZER — — 2L Ll <br /> — — <br /> 111 F- <br /> II - � I I El El <br /> w <br /> cl SUPPORT MEN'S — — I I Q <br /> II I � � I I <br /> Mi Li <br /> I_ 11 El <br /> / I I I � I � I I I � g IEl El <br /> - - - �— J I 0 0 o DINING '__j I <br /> - 101 ARCHITECT OF RECORD: <br /> COOLER \� - - � \� \ � �� - - - J � I LJ ��SE� AROy/� <br /> 110 L - -� I I L - - - - <br /> CRAIG S. <br /> BLUME <br /> CUSTOMER I 3 A * N C-31661 <br /> SERVICE REN.3/31/2021 pj <br /> 100 I i 'Z -ay <br /> �y <br /> I I <br /> I �I <br /> 11 I IW � � w <br /> I , I ~ � u <br /> CREW <br /> ROOM 4 <br /> 109I I DINING NOTES y <br /> 10 NO WORK IN THIS AREA; <br /> OFFICE I �, i EXISTING TO REMAIN, U.N.O. ILIS <br /> 108 KITCHEN 6 I I 5 <br /> 105 <br /> L 2 m � <br /> Q <br /> — o a <br /> c w Cl Q°^ N <br /> a `N o <br /> w waa � <br /> W o� °:� <br /> C <br /> 7 n�� <br /> 7 <br /> Hl <br /> C N <br /> Q 0 <br /> OL ° N.a O 2.0 <br /> d O Opp , O <br /> v � o 2 ;u vo) �� o <br /> KITCHEN & BOH NOTES �' a o ami�°p a o <br /> • NO WORK IN THIS AREA; ° J L ai ° a� c <br /> EXISTING TO REMAIN, U.N.O. I o <br /> \ \ / I o o L a•;� <br /> a � � � � � <br /> 0.5 <br /> ORDER I I o c o o - ° c <br /> — V <br /> U U C-° 3 ° C O L <br /> +' c o O �+ <br /> 107 PRESENTER - - - - - - - - - o 0 0 0 o c 0 <br /> qll <br /> ITHI 6 v+ +L N+L+U L.' E <br /> OE 2 C V'o.5', ° y 0 <br /> p 0 c X+, <br /> N N U c N� N <br /> c U t d L U p <br /> U U� � <br /> t)i o y p c ° <br /> O ° _� V <br /> a m Nw Oo U <br /> Ul O•V N <br /> LEGEND0 0 :3 �uo) 3 <br /> � 0u <br /> ° O U <br /> -20 <br /> C — — EXISTING CONSTRUCTION TO 6 c' 01+_'� <br /> BE REMOVED o 3 w` <br /> Cc-v 3 o <br /> w voLzpov <br /> EXTENT OF EXISTING o ® ° �`,, a�+'v v c <br /> CONSTRUCTION TO BE REMOVED uj :E a'o N <br /> 1 2 o0= 0= <br /> DEM0 PLAN EXISTING CONSTRUCTION H a 3 °c of <br /> TO REMAIN w <br /> D1 .1 1/411 1 -0 w <br /> r � o °' mz w04 <br /> M w <br /> w O o o f U) 3 co <br /> z > N ww cn <br /> GENERAL NOTES DEMOLITION KEYNOTES (NOT ALL KEY NOTES MAY BE USED) � N w �' o � N <br /> oQ o � of oo Uiu <br /> 1. REFER TO A1.1 FOR NEW PLAN CONFIGURATION. VERIFY ALL DIMENSIONS OF REBAR INTO EXISTING SLAB W/ EPDXY GROUT. REPLACE OR REPAIR ANY 18. GC TO VERIFY EXISTING MCCAFE SYSTEM INSTALLATION PER THE FOLLOWING REMOVE EXISTING MENU BOARDS, TO BE RELOCATE, STORE IN A cn c5 <br /> DEMOLITION WITH A1.1 VAPOR BARRIERS DISTURBED DURING EXCAVATIONS. CRITERIA REQUIRED BY THE ORANGE COUNTY HEALTH DEPARTMENT— O SAFE & SECURE AREA DURING CONSTRUCTION. N <br /> 2. DIMENSIONS ARE TO FACE OF FINISH AND/OR TO COLUMN REFERENCE LINES, 9. CONTRACTOR SHALL PROVIDE ALL TEMPORARY BRACING AS REQUIRED TO 18.1. MILK TUBING OUT OF TEMPERATURE CONTROL SHALL NOT EXCEED 18 REMOVE EXISTING GLAZING. `14 <br /> U.N.O. MAINTAIN STRUCTURAL STABILITY OF THE EXISTING STRUCTURE DURING ALL INCHES. S rn <br /> PHASES OF CONSTRUCTION. 18.2. THE UNIT DRAINS DIRECTLY TO A FLOOR SINK VIA A RIGID LINE. Q <br /> 3. THESE DRAWINGS WERE PREPARED BASED ON INFORMATION ATTAINED FROM A o <br /> 18.3. ALL HOLES AND GAPS THROUGHOUT THE UNIT MUST BE SEALED WITHIN REMOVE EXISTING ORDER POD AND POS <br /> SITE SURVEY. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS IN FIELD 10. PROTECT FROM DAMAGE DURING CONSTRUCTION ALL EXISTING WALLS, FLOORS, EIGHTH OF AN INCH WITH APPROVED MATERIALS SUCH AS PLASTIC, <br /> 3 <br /> PRIOR TO DEMOLITION & NOTIFY THE ARCHITECT IN CASE OF DISCREPANCIES CEILINGS, ETC. THAT ARE TO REMAIN. CONTRACTOR TO PATCH & REPAIR ANY FOODAN EIGRADE SILICONE, AND/OR STAINLESS STEEL). <br /> IMMEDIATELY. DEMOLITION IS TO BE EXECUTED SO AS NOT TO DISTURB DAMAGED PORTIONS OF THE EXISTING BUILDING AS REQUIRED TO MATCH THE <br /> EXISTING STRUCTURAL & ROOFING SYSTEMS, AND OTHER AREAS THAT ARE EXISTING ADJACENT CONSTRUCTION & FINISHES. 18.4. ALL TUBING MUST BE TRANSPARENT. REMOVE EXISTING OVERSHELF COUNTER. <br /> INTENDED TO REMAIN INTACT. VERIFY ALL CONSTRUCTION TO BE REMOVED S <br /> THAT IS NOT INTEGRAL TO STRUCTURAL SYSTEM PRIOR TO DEMOLITION UNLESS 11. THIS PLAN INDICATES A GENERAL SCOPE OF WORK TO BE PERFORMED AND <br /> NOTED. DOES NOT RELIEVE THE CONTRACTOR TO COMPLETE THE BUILDING O EXISTING SSBB TO REMAIN; PROTECT DURING CONSTRUCTION. Q <br /> MODIFICATIONS AS SHOWN AND REQUIRED BY THE CONTRACT DOCUMENTS, <br /> 4. ALL DIMENSIONS SHOWN AS EXISTING SHOULD BE FIELD VERIFIED BY INCLUDING BUT NOT LIMITED TO PLUMBING, ELECTRICAL & HVAC WORK. u <br /> CONTRACTOR PRIOR TO DEMOLITION. VERIFY ALL DEMOLITION WORK W/ NEW 12. IF CONTRACTOR ENCOUNTERS ANY HAZARDOUS MATERIALS DURING DEMOLITION EXISTING BULKHEAD TO REMAIN; PREP FOR NEW FINISHES; SEE U o <br /> CONSTRUCTION & INSTALLATION DRAWINGS PRIOR TO BEGINNING O NEW WORK PLANS. J w <br /> CONSTRUCTION. OR CONSTRUCTION, HE SHALL IMMEDIATELY SUSPEND WORK & NOTIFY THE Q <br /> MCDONALD'S AREA CONSTRUCTION MANAGER BEFORE PROCEEDING. m �' z m <br /> O EXISTING VALANCE TO REMAIN CD 0 Q <br /> 5. DEMOLITION CONTRACTOR TO COORDINATE & REVIEW ALL CONSTRUCTION 7 o w <br /> 13. ALL DEMOLITION SHALL BE CARRIED OUT IN A SAFE MANNER & IN STRICT z ui D U <br /> DOCUMENTS & DETERMINE THE EXTENT OF DEMOLITION WORK & BECOME � — w z N <br /> FAMILIAR WITH THEM THOROUGHLY BEFORE PERFORMING ANY DEMOLITION ACCORDANCE WITH OSHA REGULATIONS. 0 � N <br /> REMOVE EXISTING SOFFIT AND LIGHT FIXTURES AS REQUIRED. Q cn <br /> WORK. BY THE ACT OF STARTING DEMOLITION, THE CONTRACTOR WILL BE 14. THE SUB—CONTRACTOR SHALL FIELD VERIFY THE EXTENT OF DEMOLITION. THE S � �` O w <br /> DEEMED TO HAVE COMPLIED WITH THE FOREGOING, TO HAVE ACCEPTED SUCH WORK INCLUDES, BUT IS NOT LIMITED TO THE DEMOLITION AND REMOVAL OF � = 0 0 <br /> CONDITIONS, AND TO HAVE MADE THE NECESSARY ALLOWANCES IN PREPARING ANY WALLS, COUNTERS, FURNITURE, BULKHEADS, DOORS, PLUMBING, EXISTING KIOSK TO REMAIN L m w a <br /> HIS BID. MECHANICAL AND ELECTRICAL ITEMS INCLUDING CONDUITS AND DUCTWORK AS O z w w <br /> REQUIRED TO COMPLETE THE INSTALLATION O o `O <br /> 6. ELECTRICAL DEMOLITION NOTE: REFER TO ELECTRICAL DRAWINGS FOR DETAILED SHOWN ON THE DRAWINGS OR AS REQC� <br /> ELECTRICAL DEMOLITION NOTES. <br /> OF THE NEW WORK FOR A COMPLETE JOB. REMOVE EXISTING McCAFE SIGNAGE ABOVE L g <br /> 1 Q <br /> 7. VERIFY DISPOSITION OF ALL FURNISHINGS, MILLWORK, LIGHTING FIXTURES, ETC. 15. REMOVE ANY SINKS, WATER CLOSETS, URINALS, LAVATORIES, FLOOR DRAINS, w � 0 <br /> NOTED ON DRAWINGS AS WELL AS ALL ASSOCIATED PLUMBING ACCESSORIES. EXISTING CEILING AND GRID TO REMAIN ABOVE. (n <br /> TO BE REMOVED W/ OWNER. ALL ITEMS TO BE DISPOSED SHALL BE 11 � <br /> DISPOSED OF OFF—SITE AND IN AN EXPEDITIOUS MANNER. CAP, PLUG ALL ABANDONED SUPPLY & WASTE LINES. PATCH & SEAL ALL O PATCH, REPAIR AND REPLACE DAMAGED AREAS OF CEILING AS O X U) o X w <br /> FLOOR PENETRATIONS. SEE MECHANICAL & PLUMBING DRAWINGS FOR REQUIRED FROM DEMOLITION OF GYP BOARD SOFFIT. c\1 W o v w N o <br /> 8. SAWCUT & REMOVE EXISTING SLABS AS REQUIRED FOR UNDERGROUND DETAILED DEMOLITION NOTES. <br /> ELECTRICAL & PLUMBING LINES. REFER TO PLUMBING, ELECTRICAL & KITCHEN <br /> DRAWINGS FOR ALL SAWCUTS & TRENCHING WORK REQUIRED. ALL CONCRETE 16. WHEN UTILITIES ARE REMOVED, CAP & SEAL A MINIMUM OF 8" BELOW FINISH <br /> FLOOR WORK TO BE FINISHED FLUSH WITH EXISTING FLOOR. DOWEL NEW FLOOR OR A MINIMUM OF 6" ABOVE FINISH CEILING. o <br /> SLABS TO EXISTING W/ #4 REBAR ® 24" O.C. EACH SIDE (STAGGERED). 17. SEE D2.1 DEMOLITION ELEVATIONS, IF REQUIRED, FOR EXTENT OF EXTERIOR w • <br /> REBAR TO EXTEND 6" INTO EXISTING SLAB & ACROSS CUT OPENING. SECURE DEMOLITION. D 1 <br /> co DEMO PLAN <br />
The URL can be used to link to this page
Your browser does not support the video tag.