10d NAIL (FOR WOOD) OR >_ <br /> 8" MAX #10 SCREW (FOR METAL) #12 GA. VERT. WIRE HANGER, ; m <br /> Ilk ROOF FRAMING MEMBER OR SECONDARY GRID LEVEL ADJACENT TO TUBE <br /> FRAMING MEMBER AS REQ'D. UNDERSIDE OF FLR. OR ROOF STRUCT. ABOVE <br /> DONN COMPRESSION POST. MODEL TO BE <br /> 4-12 GA. WIRES 90° DETERMINED BASED ON REQUIRED LENGTH: <br /> TO EACH OTHER VSA 18/30: LENGTH 18" TO 30" <br /> 45° TO PLANE VSA 30/48: LENGTH 30"-48" <br /> OF CEILING I VSA 48/84: LENGTH 48"-84" <br /> VSA 84/102: LENGTH 84"-102" <br /> VSA 102/120: LENGTH 102"-120" <br /> SUSP. ACOUSTICAL TILE VSA 120/144: LENGTH 120"-144" <br /> MAIN T-BAR RUNNER ICC-ESR-1222 z <br /> 3/4" CLEAR MIN. SEE NOTE ABOVE. 45 DEGREE TYP. <br /> 2" X 2" ANGLE MOLDING- USG OR EQUAL TO BE MAIN RUNNER <br /> FASTENED WITH 14D WOOD SCREWS @ 16" O.C. COMPRESSION STRUT W/ LATERAL v <br /> USE USG ACM7 SEISMIC CLIP AS ALT. ESR-1222 CROSS RUNNER BRACING @ 12'-0" MAX. EA. DIRECTION w <br /> & 6'-0" MAX. FROM PERIMETER WALLS <br /> 2X BLOCKING AT CEILING <br /> TYPICAL INTERIOR PARTITION WALL <br /> 1. GRID SYSTEM TO BE HEAVY DUTY <br /> T-BAR. <br /> xa 2. INSTALL PER ESR-1222 IN EACH <br /> ORTHOGONAL HORIZONTAL DIRECTION, <br /> ONE END OF THE CEILING GRID <br /> 0j SHALL BE ATTACHED TO THE CLOSING I <br /> 3'-0" MAX 6'-0" 3'-0" MAX ANGLE. THE OTHER END SHALL HAVE <br /> 10 A 0.75" CLEARANCE FROM THE WALL. <br /> w <br /> 3. ENDS OF MAIN RUNNERS AND CROSS I Q <br /> RUNNERS SHALL BE TIED TOGETHER <br /> TO PREVENT THEIR SPREADING <br /> 4. ALL TERMINAL ENDS OF MAIN ; w <br /> o RUNNERS AND CROSS TEES MUST o' <br /> HAVE A VERT. HANGER WIRE WITHIN <br /> N ARCHITECT OF RECORD: <br /> 8" OF EA. WALL OR CLG <br /> 2'-0" DISCONTINUITY. ���SED ARCh,/� <br /> 0j CRAIG S. fir, <br /> � BLUME <br /> * N .-C-31661 <br /> REN.3/31/2021 co <br /> dy <br /> ly <br /> y� <br /> ORA �X 0 <br /> W °i <br /> 0 ° <br /> REFER TO BUILDING CODE MANUAL a <br /> 0j CODE OF LOS ANGELES DEPARTMENT <br /> OF PUBLIC WORKS BUILDING AND <br /> T T SAFETY DIVISION BASED ON 2011 <br /> LACBC - SUSPENDED CEILING SYSTEMS �, <br /> CEILING PLAN VERTICAL COMPRESSION STRUT X LATERAL WIRE BRACING W <br /> NOTE: m 0 <br /> SEISMIC CEILING DETAILS 12 GA. VERTICAL WIRES SHALL BE USED AT 48" O.C. ° <br /> Q P C <br /> 1 1 PERIMETER HANGARS SHALL BE 8" MAX. FROM WALL AND O N <br /> A1 .2a N.T.S. NOT MORE THAN 1 IN 6 OUT OF PLUMB. }N m ° <br /> V <br /> w 5 P <br /> V n N 3 <br /> ROOF 3/4" DIA THREADED ROD OF EXISTING ROOF DECK FOR <br /> EXTEND PLYWOOD TO UNDERSIDE c: <br /> DECKING DRILLED BETWEEN DOUBLE v �• , o o N <br /> WIRE HANGER 2x4 PROVIDE DOUBLE NUT & DRAFT STOPPING a o Loo-v o o'o <br /> vv 3 OVER-SIZED STEEL EXISTING ROOF JST. TO REMAIN, `o °�' <br /> aa� a� yv � � <br /> v WASHER BOTH SIDES �5 NP. J a ` a o o v <br /> < I WOOD ROOF JOIST SIMPSON A34 FRAMING ANGLE -o J o a�v ° o 0 <br /> � m DBL 2x4 FLAT w 10d NAILS C� _ " o °' ` <br /> o m 12" O.C. 2 ROWS STAGGERED o Cess C� EA. SIDE OF 2X4 0 0% ° a N a �' <br /> v �0 2x4 ON EDGE (SPANNING A MIN. B/ JOIST o a <br /> cvv PROVIDE FULL ELEV. VARIES a 0 B.= c 0- <br /> < w a OF 2 PANEL POINTS). INSTALL ONE <br /> m J of DEPTH BLKG ° °s o °='rn o- <br /> w w BOLT ABOVE EACH BOTTOM CHORD 2X4 © 16 O.C. VERT. STUD & o C o o-i v = <br /> Z Z C� EA. SIDE BRACE TO ATTACH W/ (4)-10d N = _� 3 _ °' 0 <br /> OF 2X4 -� _ o-v+• <br /> w �o PIN TO HOLD 2X'S IN PLACE O r <br /> 0 00 OUTLET & JUNCTION BOX - SEE r L o.2 ° o = <br /> COMMON NAILS C� 48 O.C. ° v ° o o = o <br /> ELECTRICAL 2X4 DIAG. BRACE <br /> ATTACH INTERMEDIATE STUDS +' N may;a� v <br /> @ 48" O.C. ATTACH W/ (2)-10d COMMON NAILES °`o c c°j E�' o o <br /> GUSSET TO BOTH w s 0 °r y <br /> BRACE AND VERT. CONT. 2X6 .2 -J _w o v L <br /> CEILING AS SCHEDULED F0 <br /> STUD W/ (3)-10d a �o:6 (D v L <br /> COMMON NAILS CONT. CAULK WHERE PLYWOOD ~ �° v v = N,° <br /> THREADED ROD TO PROJECT MEETING 2X, TYP. C a= °r _ i c <br /> BELOW CEILING TO RECEIVE TILE OVER Y2" N o <br /> MONITOR BRACKET COVER CEMENT BOARD CEILING AS SCHEDULED, TYP. Q � a N <br /> w/ 3" BEAUTY TUBE PROJECT <br /> THRU CEILING 2 INCHES OVER Y2" PLYWOOD 2X4 VERT. STUDS @ 16" O.C. o ° v v 3� ° ° <br /> C" v, o <br /> C t L <br /> NOTCH REAR SIDE OF BEAUTY ORDER READY BOARD 2 °'� a�c ° 3 a, <br /> TUBE WITH 3/4" x 3" OPENING (PROVIDE BLOCKING o o r o-o o <br /> FOR CABLES AND WIRING. AT BRACKET o ® v` >,3 „�_0 to c <br /> CEILING AS SCHEDULED w �. <br /> CONT. 2X4 PLATE N N ' � 0 o o °o <br /> CONNECTON) Q N a o 3 N - <br /> a_ N °+_+ L-+, Ne0 <br /> MONITOR BRACKET <br /> B SOFFIT ui -c `a'3 ° _m O m <br /> 6'-8" A.F.F. <br /> g ACOUSTIC CEILING DETAIL g MONITOR INSTALLATION DETAIL 7 NOT USED 6 SECTION THRU VALANCE <br /> } _ o � o <br /> > » n n >_ of o m Z w U N <br /> A1 .20 1 1 /2)) = 1 —0 COORDINATE W/ DECOR A1 .2a NOT TO SCALE A1 .2a 1 1 /2 = 1 '—O" COORDINATE W/ DECOR Al .2a 1 " = 1 '-0" m > w o o w N_ o <br /> Q � vNi � w � Ld aN <br /> — Q Q <br /> ROOF DECKING BUILDING STRUCTURE o Q o o � <br /> 1-5/8 UNISTRUT Q 12 O.C. cn <br /> MAIN TEE SPLICE ATTACHED TO BOTTOM CHORD OF N <br /> COUPLING (OCCURS SIDE MOUNTING LEVELING m ROOF JOIST (2 MIN.) N <br /> AT RANDOM) LUG BY FIXTURE MFR. <br /> DETAIL AT WALL � INSTALLATION BY Q <br /> ELECTRICIAN AS PART OF WALL MOULDING 1-5/8" UNISTRUT ATTACHED TO <br /> FIXTURE (2 PER SIDE) Z 1-5/8 UNISTRUT POST BASE. s <br /> CAN BE "C" OR "L" o ________ + <br /> HILTI CC27 CLIP <br /> -- ---- #12 SAFETY WIRE FOR EQUAL <br /> Q TIED TO SAFETY WIRE <br /> F,E-11 + SUPPORT HOLES & uj <br /> CROSS TEE- MAY BE "A" z FASTENED TO BLDG. Q <br /> 1-1/2" OR 1 " HIGH SECTION "A <br /> -A" FIXTURE VARIES + STRUCTURE. MINIMUM O w o <br /> AND MAY BE 2'-0" OR A WITH MFR (2) SAFETY WIRES > <br /> 4'-0" O.C. w PER LIGHT FIXTURE U z <br /> TILE OPENING Q < PLACED AT DIAGONAL m 0 Q z Q <br /> CORNERSz o w of <br /> NOTES: + CEILING AS SCHEDULED Q 0 ui j w ) <br /> 1. AT EACH END OF LIGHT FIXTURE AN INTERLOCKING CROSS TEE OR J `` w w <br /> MAIN TEE-48" O.C. o bi 0 3r <br /> MAX. SHAPE AND LOCKING BAR MUST BE USED cr z 0 o <br /> ( CP SEE A4.4 L� m w Q J <br /> DESIGN AS APP'D.) 2. THE TOTAL WEIGHT OF A LIGHT FIXTURE AND OTHER EQUIPMENT z ,- w M <br /> THE RECESSED FIXTURE (AIR BOXES, ETC.)AND CEILING MATERIAL SUPPORTED BY THE MAIN O O O z cO <br /> 12 GA. GALV HANGER WIRE BEAM MUST NOT EXCEED THE ALLOWABLE DEFLECTION OF 1 360 OF EXPOSED T-BAR CEILING W g w <br /> MAY BE SUPPORTED BY / CURATED PANEL FASTENED TO Z z � 0 <br /> NOT TO EXCEED 4'-6" O.C. IT'S SPAN. DEFLECTION DATA MUST BE FURNISHED AND CERTIFIED UNISTRUT. ALL CONNECTIONS TO BE LIGHT FIXTURE o Fr w o <br /> THE MAIN TEES SPACED NOTE: O� w <br /> ALONG MAIN RUNNER. SEE 2'-0" OR 4'-0" O.C. BY THE MANUFACTURER. PROVIDED BY VENDOR SAFETY WIRE ALL WIRES ARE TO BE 7- � w o <br /> SECTION A-A. ATTACH TO 3. SURFACE OR PENDENT FIXTURES MUST BE INDEPENDENTLY SUPPORT HOLE, J O X vii o x w <br /> TAUT WITH A MINIMUM OF 3 <br /> EXISTING BLACK IRION SUPPORTED FROM FLOOR OR ROOF CONSTRUCTION. TIGHT TURNS AROUND SELF N LLJ o w01 <br /> TYPICAL <br /> - U3 0 <br /> TYPICAL <br /> ci <br /> 5 CEILING GRID DETAIL 4 CURATED PANEL INSTALL DETAIL 3 NOT USED <br /> 1 LIGHT FIXTURE SUPPORT DETAIL Z <br /> uj <br /> A1 .2a NOT TO SCALE REFERENCE ONLY A1 .2a 1 1 /2" = 1 —0 A1 .2a A1 .2a NOT TO SCALEU-i A 1 <br /> a <br /> U) CEILING DETAILS <br />