Laserfiche WebLink
o m <br /> Q m <br /> q/Y\NrE <br /> ❑3 <br /> ❑3 <br /> ❑3 z <br /> 0 <br /> v u <br /> E m <br /> B m <br /> ' o <br /> F3 NEW DIGITAL MENU BOARD. <br /> REUSE EXISTING CIRCUITRY <br /> AND CONTROL. REFER TO <br /> DIGITAL MENU BOARD DETAIL <br /> ON SHEET E4.0. o o d z <br /> 0 <br /> ° CP:* Cn <br /> F38 � <br /> w <br /> ❑Ili 7 � w <br /> z <br /> ❑3 O <br /> DUAL POINT FRONT w <br /> COUNTER LAYOUT CONFIRM 0� <br /> LAYOUT WITH MCD <br /> 0 <br /> CONSTRUCTION SUPERVISOR <br /> REFER TO DETAIL ON <br /> F34 5 SHEET E4.0 m w <br /> m <br /> 0 0 <br /> ENGINEER OF RECORD: <br /> FTHEKITCHEN <br /> XISTING ELECTRICAL CIRCUITRY 191 <br /> j 1 ��Sa/nQ <br /> EQUIPMENT ASSOCIATED WITH MODERNIZATION. NO ADDITIONALAP4:6DED. I 7 <br /> II I <br /> CP:* J it 8 <br /> 2 ¢f7 �EsrTAlGht 21`� <br /> ° IF OF CAUF01' <br /> ❑3 11/12/21 <br /> 6 <br /> a N <br /> AP-4:(2,4) W O <br /> REUSE EXISTING ELECTRICAL CIRCUITRYo <br /> FROM THE SSBB BEING REMOVED FOR <br /> THE NEW ABS 2.0 <br /> O O O <br /> } <br /> W <br /> 'kin <br /> � n � <br /> 3 <br /> � �m �� <br /> W o� 0 1 <br /> 3 � 5 <br /> RELOCATE/REUSE EXISTING ELECTRICAL CIRCUITRY (D <br /> FOR THE KITCHEN EQUIPMENT ASSOCIATED WITH p <br /> \Nil <br /> THE SERVICE AREA MODERNIZATION. NO ADDITIONAL T ° ° Q) <br /> FIELD VERIFY ❑3 LOADS WILL BE ADDED. Q o ° o o.o <br /> LOCATIONS OF EXISTING <br /> POWER PANELS u J o Q) o 0 <br /> .1D E ��� <br /> J <br /> =° S O N-° U Q p <br /> N N <br /> C <br /> O n Q + Q <br /> 0 U o C L U <br /> � U C N i L U <br /> U <br /> N n N N N <br /> KEY NOTES 0 0 0 <br /> 1 ELECTRICAL POWER PLANL <br /> 0 o 0-3;_ <br /> ° a <br /> 1 EXISTING KIOSK TO BE RELOCATED. ° o '-0 <br /> N p U O p O <br /> Cn u <br /> 4 CP:* IF THERE IS NOT SUFFICIENT CAPACITY IN THE EXISTING VERIFY F OPTIONAL TABLE TRACKER SYSTEM S TO BE USED. F Q, -1 o D•� <br /> COMPUTER PANEL FOR THE NEW COMPUTER CIRCUITS , THEN USED, PROVIDE 2#12, 1 #12 GRD, & %2 ISOLATED GRD. TO ° <br /> F2C o °- ° <br /> GENERAL NOTES DEMOLITION NOTES CONTRACTOR IS TO REPLACE THE EXISTING PANEL WITH A NEW 42 AVAILABLE SPARE 20A/1 P BREAKER WITHIN CP PANEL. CONNECT p Cn <br /> CIRCUIT PANEL OF THE SAME AMPACITY AS EXISTING. NEW PANEL CIRCUIT TO TWO (2) IG RECEPTACLES, ONE (1) RECEPTACLE FOR <br /> 1 . SEE ELECTRICAL SCHEDULE FOR PANEL & CIRCUIT BREAKER D1 . THE ELECTRICAL CONTRACTOR SHALL RELOCATE EXISTING SHALL BE OF THE SAME MAKE, MODEL, MANUFACTURER AND HAVE SERVER (TYPICALLY LOCATED IN I.T. CLOSET AND ONE r <br /> ASSIGNMENT, VOLT/PH, FLA, BREAKER SIZE, COND/WIRE, POWER, DATA, AND TELEPHONE DEVICES IN THE BATHROOM THE SAME AIC RATING AS THE PANEL BEING REPLACED. <br /> (1 )RECEPTACLE FOR MONITOR (TYPICALLY LOCATED AT HLS OR � �� � �' <br /> RECEPTACLE TYPE, HEIGHT ABOVE FINISHED FLOOR, AREAS TO BE AFFECTED. REFER TO DEMO PLAN D1 .0 FOR O (- n."� o� 0 <br /> REQUIREMENTS & REMARKS FOR ALL ELECTRICAL EQUIPMENT. AFFECTED AREA. PICKUP COUNTER). COORDINATE EXACT LOCATIONS) IN THE FIELD 0 T <br /> AND REQUIREMENTS WITH MANUFACTURER'S INSTALLATION Q CO� L L E <br /> PANELBOARD: AP-4 (EXISTING) INSTRUCTIONS. o N L° 10) <br /> 2. VERIFY OEP DROP CORDS DO NOT FALL BELOW HEIGHTS LISTED D2. THE ELECTRICAL CONTRACTOR SHALL RELOCATE EXISTING �7 ° ° <br /> ON ELECTRICAL SCHEDULE. RECEPTACLES SHOULD BE LOCATED POWER, DATA, AND TELEPHONE DEVICES FOR THE WALL BUS AMPS:225A EQUIPMENT GROUND BUS ❑3 EXISTING POWER IN THIS AREA TO REMAIN. o � o o�'3 o a <br /> AT HEIGHTS TO AVOID CONTACT WITH HOT APPLIANCES. RELOCATION. REFER TO DEMO PLAN D1 .0 FOR AFFECTED MAIN SIZE/TYPE:MLO <br /> -u cn c <br /> AREA. VOLTS/PHASE:208Y/12OV,3PH,4W REUSE EXISTING FRONT COUNTER CIRCUITS WHERE POSSIBLE. o ° <br /> 3. RE–USE EXISTING CIRCUITRY AND BREAKERS. CONFIRM SERVES: KITCHEN F] REFER TO DETAIL ON SHEET E4.0. PROVIDE (4) 20A, 120V I.G. a- � <br /> D3. RE–USE EXISTING CIRCUITRY AND BREAKERS. CONFIRM 3 ° <br /> AMPERAGE AND BREAKER SIZE AS SHOWN ON SCHEDULE. IF LOCATION: BOH MOUNTING:SURFACE CIRCUITS FROM PANEL CP TO FEED FRONT COUNTER POS � <br /> NOT, PROVIDE NEW CIRCUIT BREAKER AND WIRE. AMPERAGE AND BREAKER SIZE AS SHOWN ON SCHEDULE. IF EQUIPMENT, TABLE TRACKERS AND UBER TABLET. (1) 20A, 120V <br /> NOT, PROVIDE NEW CIRCUIT BREAKER AND WIRE. CKT DESCRIPTION VA/PHASE WIR BKR P P BKR WIRE VA/PHASE DESCRIPTION CKT � <br /> CIRCUIT FROM A SPARE C/B IN AN AP PANEL TO FEED 2 DCO'S <br /> NO. A B C NO. AMP AMP NO. A B C NO. a m O o o <br /> SERVING THE BAKED GOODS DISPLAY. IF THERE IS NOT o w <br /> 1 2 30 10 2080 FROZEN CARB. BEV. 2 SUFFICIENT CAPACITY IN THE EXISTING COMPUTER PANEL FOR m11� � 0 � co o Q0 <br /> 3 existing load 40 3 2080 4 G THE NEW COMPUTER CIRCUITS, THEN CONTRACTOR IS TO Q v m w w o N <br /> SYMBOLS AND ABBREVIATIONS 5 1 15 12 300 BAKED GOODS 6 REPLACE THE EXISTING PANEL WITH A NEW 42 CIRCUIT PANEL o – Q w Q �; u <br /> 7 existing load ' 20 1 1 20 existing load 8 OF THE SAME AMPACITY AS THE EXISTING. NEW PANEL SHALL BE . 71 <br /> O <br /> 9 existing load 20 1 1 20 existing load 10 OF THE SAME MAKE, MODEL, MANUFACTURER AND HAVE THE <br /> SYMBOL DESCRIPTION SYMBOL DESCRIPTION 11 existing load 20 1 1 20 existing load 12 SAME AIC RATING AS THE EXISTING PANEL. <br /> 13 existing load 20 1 14 Ln <br /> K� SINGLE POLE SWITCH, 3W–THREE WAY SWITCH, K=KEYED SWITCHED, �T MANUAL SWITCH (T–THERMAL OVERLOADS) 15 existing load 20 1 3 20 existing load 16 ❑ ELECTRICAL RACEWAY PROVIDED WITH COUNTER AND INSTALLED <br /> VS=VACANCY SWITCH O BUZZER 17 existing load 20 1 18 5 BY E.C. REFER TO DETAIL ON SHEET E4.0 <br /> 19 space 1 1 20 existing load 20 0 <br /> ® JB WITH DUPLEX CONVENIENCE OUTLET (FLUSH WITH CEILING) © BUTTON FOR BUZZER 21 1 20 existing load 22 1 .5" CONDIUIT AND BOX AT 7'-10" FOR RELOCATED ORB. REUSE <br /> 23 existing load 30 3 1 20 existing load 24 <br /> �{ JB WITH SINGLE CONVENIENCE OUTLET G PANELBOARD g HI EXISTING POWER AND DATA. <br /> 25 1 20 existing load 26 <br /> JB WITH DUPLEX CONVENIENCE OUTLET A AMPERES 27 existing load 20 1 1 20 .existing load 28 <br /> Q <br /> 29 space 1 1 20 existing load 30 PROVIDE POWER WITHIN CEILING FOR CONNECTION TO SELF C� <br /> JB WITH TWO DUPLEX CONVENIENCE OUTLETS ACM AREA CONSTRUCTION MANAGER 1, o <br /> 31 space 1 1 space 32 ORDER KIOSKS. COORDINATE EXACT LOCATION OF KIOSKS WITH > <br /> JB WITH FLUSH FLOOR MOUNTED OUTLET AFF ABOVE FINISHED FLOOR 33 space 1 1 .space 34 DECOR DRAWINGS. PROVIDE 2#12, 1 #12 GRD., & 1 #12 ISOLATED U Q <br /> 35 space 1 1 space 36 GROUND ON A 20A DEDICATED CIRCUIT FED FROM THE CP PANEL J z <br /> 37 1 space 38 FOR EACH KIOSK. <br /> JB WITH SPECIAL PURPOSE OUTLET C CONDUIT m o > <br /> ® JB WITH ISOLATED GROUND OUTLET �, Z <br /> =IG4700A, =IG5262 CCT CIRCUIT 39 existing load 20 3 1 space 40 > Ld _ < <br /> IG471 0, IG5261 , 41 1 s ace 42 Q v <br /> EC ELECTRICAL CONTRACTOR EXTEND 2 1/2" CONDUIT FROM 1 '-2" AFF TO ABOVE CEILING u� � Ld Ld <br /> SUBTOTAL 2,080 2,080 300 SUBTOTAL FOR POS DATA CABLES. IF THERE IS NOT ENOUGH SPACE IN o w o <br /> NINTERCOM STATION W/ 3/4"C TO MAIN STATION GC GENERAL CONTRACTOR <br /> TOTAL PHASE A-VA 2,080 LOAD CONN.VA DF LOAD CONN.VA DF WALL TO ROUTE CONDUIT TO ABOVE CEILING, CONTRACTOR TO m Q <br /> TELEPHONE JACK <br /> GFI/GFCI GROUND FAULT CIRCUIT INTERRUPTER AMPS 17 COOLING 1.00 REFRIGERATION 1.,00 TRENCH TO NEAREST FULL HEIGHT WALL AND EXTEND 2 1/2" O z o w <br /> —.. N <br /> O JUNCTION BOX – WALL OR CEILING MOUNTED TOTAL PHASE B-VA 2,080 HEATING 0 SIGNIDISPLAY 1 25 CONDUIT TO ABOVE CEILING. W Q w <br /> GNDGROUND ......... ......... ......... ...... ... ......... ......... ......... ......... ......... ......... <br /> AMPS 17 LIGHTING 1.25 KITCHEN 4,160 0.65 z o z 00 <br /> ❑N DISCONNECT SWITCH IG ISOLATED GROUND TOTAL PHASE C VA 300 RECEPTACLES 1.0/.5 EXISTING 1.00 � w <br /> PROVIDE 5-20R RECEPTACLE FOR FUTURE DELIVERY TABLET AT u_ w o <br /> AMPSI 3 1 MOTORS 1.00 LARGE MOTOR 1.25 TOTAL DEMAND v � [ – <br /> O THERMOSTAT SENSOR W/ 1/2"C UP TO CEILING SPACE JB JUNCTION BOX 9 3'-4" AFF. EXTEND NEARBY APPLIANCE CIRCUITRY TO NEW J CD X 0 X w <br /> TOTAL PNLBD-VA 4,460 SUPP HEAT 1.00 SHOW WINDOW 1.25 3,004 VA w 0 w � o <br /> MOTOR CONNECTION KES KITCHEN EQUIPMENT SUPPLIER AMPS 12 MISC EQUIP 300 1.00 LTGTRACK 1.00 gq RECEPTACLE VERIFY CIRCUIT HAS 1 .5 AMPS OF AVAILABLE N W o o <br /> AMPACITY. FIELD VERIFY LOCATION WITH ACM/OWNER. <br /> CONDUIT RUN CONCEALED IN CEILING OR WALLS MLO MAIN LUGS ONLY LOAD DESCRIPTIONS SHOWN AS LOWERCASE ARE CIRCUITS EXISTING TO REMAIN. <br /> "G" - PROVIDE GFCI PROTECTION FOR ALL KITCHEN EQUIPMENT. <br /> / \ CONDUIT RUN IN FLOOR SLAB WP WEATHERPROOFEl1 <br /> LLJ <br /> HOT (SHORT), NEUTRAL (LONG), EQUIP GRD LONG WITH DOT), & w • <br /> X & 'X' DENOTES ISOLATED GRD <br /> OS GEEING MOUNTED OCCUPANCY SENSOR U) POWER PLAN <br />