Laserfiche WebLink
N <br /> � <br /> EXHAUST FAN INFORMATION — Job 3050147REVISIONS LnDESCRIPTION DATE: N J <br /> INT Q <br /> NO, TAG: FAN UNIT MODEL # CFM ESP RPM H P B;N.P VOLT FLA WEIBS)T SONES ` < <br /> Z\ .N W <br /> 1 NCA24HPFA 360 L750 1043 3:000 L7770 3' 208. 9 5 289 21 � Q Q <br /> MUA FAN INFORMATION — Job 3050147 a <br /> UNIT TAG FAN UNIT MODEL # BLOWER HOUSING DN . . AOLEADEVAPOO' OOEWEIGHT O <br /> NO, CFM ESP B H.P @ VOLT FLA ENERIOENEROWB NDB LEAVINSONES Q <br /> TEMP, TEMP. TEMP, TEMP, (LBS,) > <br /> O <br /> 0 <br /> 2 A2-G15' a w <br /> C15-PB A2 3240 0,750 723 1,500 1,1100 3 208 4,6 90 0"F 65,0'F 710`F 65,0°f 626 14 E <br /> 0 Q <br /> CURB ASSEMBLIES 1 � � <br /> NO N WEIGHT ITEMW <br /> SIZE <br /> 1 # 1 48 LBS > <br /> Curb 31500'W x 31500'L x 20.000'H Vented Hinged, Q <br /> 2 # 2 42 LBS Curb 31000'W x 31,000'L x 20.000'H no <br /> N N Q <br /> # 2 Rail 4.000'W x 4 000'L x 36.000'H' V <br /> N <br /> J N <br /> C <br /> FAN #2 A2 G15 SUPPLY FAN <' - <br /> T <br /> 1 W O UNTEMPERED SUPPLY UNIT WITH 15' BLOWER IN SIZE #2 HOUSING i� ,- � <br /> 2 EMAP COOLEDISCHARGE <br /> (LP- AIR FL) RI INTAKE HOOD W/EZ FILTERS W„ �0 II a <br /> 3 DOWN -ISCHARGE AIR FLOW RIGHT -> LEFT <br /> 4. 120V WIRING CONNECTION TO ENERGIZE EVAPORATIVE COOLERS FROM UNTEMPERED SUPPLY FANS. : (D c <br /> LO \ <br /> BLOWER DISCHARGE N6 LO <br /> cl. <br /> CURB 0 J <br /> LLI <br /> Q L 0 a <br /> U) o <br /> s 1/2' 0 <br /> _ lb .j Z <br /> R O <br /> a I 19` � F <br /> 01 112' 20 Z L Ql <br /> WATER <br /> DRAIN W a w 0 <br /> 40 3/4' 18 3/4' I I, �• N Ll Q� <br /> ~ ' <br /> I' AIRFLOW 0' rn <br /> FAN #1 NCA24HPF6 - EXHAUST FAN: � _ <br /> Ll- - �` Z U W - a a <br /> 6 1/8' S 3/4" a <br /> b OU <br /> FEATURES — <br /> 43 3/8 4 1/2" 0 OU <br /> .. 0ROOF MOUNTED FANS <br /> - RESTAURANT MODEL <br /> - UL705 AND UL762 n <br /> g � w wm <br /> - AMCA SOUND AND AIR CERTIFIED FLEX CONDUIT Q Z <br /> - WIRING FROM MOTOR TO DISCONNECT SWITCH w o k a j <br /> FOR FIELD � `o W a z <br /> - WEATHERPROOF DISCONNECT WIRING � <br /> HIGH HEAT OPERATION 300°F (149°C) <br /> m <br /> - GREASE CLASSIFICATION TESTING. 129 7/81 0; � <br /> 37 lfz: NORMAL TEMPERATURE TEST Q <br /> 30 5/8 EXHAUST FAN MUST OPERATE CONTINUOUSLY <br /> T <br /> WHILE EXHAUSTING AIR AT 300°F (149'C)' 76: 1/4 <br /> UNTIL ALL FAN PARTS HAVE REACHED V <br /> THERMAL EQUILIBRIUM, AND WITHOUT ANY 37 3/8' 40 1/8' BS 1/B` <br /> DETERIORATING EFFECTS TO THE FAN WHICH: <br /> REASE DRAIN WOULD CAUSE UNSAFE OPERATION. JZ <br /> ABNORMAL FLARE-UP TEST <br /> 2 EXHAUST FAN MUST OPERATE CONTINUOUSLY : t Z) cc ; <br /> _ O <br /> WHILE EXHAUSTING BURNING GREASE VAPORS p_ p LLJ�. � 0 AT 600°F C316'C) FOR A PERIOD: OF _. AIRFLOW Z w 0 N N <br /> 15 MINUTES WITHOUT THE FAN BECOMING LIFTING u LUG :. <br /> 23 7/8 DAMAGED TO ANY EXTENT THAT COULD CAUSE <br /> _ O Z N CD <br /> AN u�s�FE CONDITION. AIRFLOW <br /> LPD C6 <br /> AIRFLOW <br /> AIRFLOWLLJ Lny)LDEK ir <br /> 28 O FILTER/CONTROLW (.) Or <br /> 43 3/s' QQ <br /> SERVICE DISCONNECT U N33 GREASE BOX W36 3/4' SWITCHQ <br /> BLOWER/MOTOR 0112' NPT � 0 w <br /> ACCESS DOOR WATER INLET U I O Z <br /> 24' SERVICE ° <br /> U W j W J M <br /> { °D CLEARANCE REQ, 00 IL <br /> DUCTWORK BETWEEN <br /> EXHAUST RISER ON HOOD 3 3/4° (/, z II= co <br /> AND FAN (BY OTHERS) r{�• .�„w31 1/2' �— <br /> 31 1/2” C)16 1/4` <br /> ° ADJUSTABLE U <br /> ,. LEG <br /> 'VENTED 20' EQUIPMENT CURB QROFESS/o <br /> { CURB 31 — S `�° y.FeF2c <br /> I 0 <br /> 20' ROOF OPENING 2' SMALLER THAN CURB DIMENSION � 31 � � w � No.21 � ^m <br /> 0 k Expires 6/30/17 <br /> 20 GAUGE U s <br /> STEEL Q r> rRUCTOaP \Q <br /> CONSTRUCTION Q { > gTF0 CALF <br /> PITCHED CURBS ARE AVAILABLE 0.. <br /> FOR PITCHED: ROOFS: <br /> 3' FLANGE. 0° cz <br /> DATE:: 6/14/2017 cz <br /> SPECIFY PITCH 12' DWG #: <br /> EXAMPLE 7/12 PITCH 30' SLOPE <br /> ROOF OPENING <br /> / 2g, DIMENSIONS <br /> 28 305014 ! � <br /> DRAWN <br /> 13. .>1 <br /> �c: W <br /> SCALE: Z <br /> PITCHED CURBS ARE AVAILABLE p> 3/4 — 1 0" z <br /> FOR PITCHED ROOFS <br /> 0' <br /> MASTER DRAWING' o IL <br /> SPECIFY PITCHc 12'' <br /> EXAMPLE+ 7/12 PITCH 30' SLOPE These products and others are availableco <br /> for <br /> dm <br /> demonstration at the Northern CA display center <br /> --For more Information or questions Contact-- c: <br /> Captive Aire Systems <br /> 1110 Burnett Ave, Suite G. Concord, CA 94520 <br /> cz <br /> Phoney (925)962-1999, Fax (925)566-8565 7Q <br /> [mall reg92@captiveaire.corn SHEET NO. <br /> 2 � <br /> CO <br /> G <br />