Pquin/ San Joaquin County
<br /> a. Environmental Health Department
<br /> 1868 East Hazelton Avenue, Stockton, CA 95205-6232
<br /> • cq., ;a• Telephone:(209)468-3420 Fax:(209)464-0138 Web:www.sigov.org/ehd
<br /> �rFORN
<br /> Food Program Official Inspection Report
<br /> Facility Name and Address: AJ FRERICHS ENTERPRISE, 28323 S MAC ARTHUR RD,TRACY 95304
<br /> #34 Warewashing Facilites Maintained
<br /> OBSERVATIONS:Provide chlorine test strips in 1 week.
<br /> CALCODE DESCRIPTION:Food facilities that prepare food shall be equipped with warewashing facilities. Testing equipment and
<br /> materials shall be provided to measure the applicable sanitization method. (I14067(f,g), 114099, 114099.3, 114099.5, 114101(a),
<br /> 114101.1, 114101.2, 114103, 114107, 114125)
<br /> #36 Equipment/Utensils/Linens: Proper Storage I Use
<br /> OBSERVATIONS:Box of single-use utensils and food container lids on the ground. Maintain all equipment 6 inches off the
<br /> ground. Correct today.
<br /> Plates in hand sink. Only store plates in 3-comp sink. Correct today.
<br /> CALCODE DESCRIPTION:All clean and soiled linen shall be properly stored non-food items shall be stored and displayed separate from
<br /> food and food-contact surfaces. (114185.3- 114185.4) Utensils and equipment shall be handled and stored so as to be protected from
<br /> contamination. (114074-114075, 114081, 114119, 114121, 114161, 114178, 114179, 114083, 114185, 114185.2, 114185.5)
<br /> #38 Approved/Sufficient Ventilation and Lighting
<br /> OBSERVATIONS:Light cover lacking in the hood. Provide in 1 week.
<br /> CALCODE DESCRIPTION:Exhaust hoods shall be provided to remove toxic gases,heat,grease, vapors and smoke and be approved by
<br /> the local building department. Canopy-type hoods shall extend 6"beyond all cooking equipment.All areas shall have sufficient ventilation
<br /> to facilitate proper food storage. Toilet rooms shall be vented to the outside air by a screened openable window,an air shaft, or a
<br /> light-switch activated exhaust fan,consistent with local building codes. (114149, 114149.1)Adequate lighting shall be provided in all areas
<br /> to facilitate cleaning and inspection.Light fixtures in areas where open food is stored, served,prepared,and where utensils are washed
<br /> shall be of shatterproof construction or protected with light shields. (114149.2, 114149.3, 114252, 114252.1)
<br /> #41 Plumbing Maintained;Approved Back Flow Device
<br /> OBSERVATIONS:Hand sink drips at the stem and cold water knob. Correct today.
<br /> CALCODE DESCRIPTION:The potable water supply shall be protected with a backflow or back siphonage protection device,as required
<br /> by applicable plumbing codes. (114192)All plumbing and plumbing fixtures shall be installed in compliance with local plumbing
<br /> ordinances,shall be maintained so as to prevent any contamination,and shall be kept clean,fully operative,and in good repair. Any hose
<br /> used for conveying potable water shall be of approved materials,labeled,properly stored,and used for no other purpose. (114171,
<br /> 114189.1, 114190, 114193, 114193.1, 114199, 114201, 114269)
<br /> OVERALL INSPECTION NOTES AND COMMENTS
<br /> OBSERVATIONS
<br /> Name on Food Safety Certificate: Expiration Date:
<br /> Warewash Chlorine(Cl): ppm Heat: °F Water/Hot Water Ware Sink Temp: 120°F
<br /> Quaternary Ammonia(QA): ppm Hand Sink Temp: 100°F
<br /> FOOD ITEM--LOCATION--TEMP°F--COMMENTS
<br /> FA0023896 PR0541691 SCO01 05/08/2017
<br /> EHD 16-23 Rev.06/30/15 Page 2 of 3 Food Program OIR
<br />
|