My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008 RETROFIT
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
COLONY
>
1553
>
2300 - Underground Storage Tank Program
>
PR0516526
>
COMPLIANCE INFO_2008 RETROFIT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2022 11:26:32 AM
Creation date
12/13/2018 1:04:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008 RETROFIT
RECORD_ID
PR0516526
PE
2361
FACILITY_ID
FA0012659
FACILITY_NAME
LOVE'S COUNTRY STORES OF CALIF #223
STREET_NUMBER
1553
STREET_NAME
COLONY
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
24534024
CURRENT_STATUS
01
SITE_LOCATION
1553 COLONY RD
P_LOCATION
05
P_DISTRICT
005
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
154
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Issue Date:August 23,1999 <br /> Revision Date:March 11,2004 <br /> Vaporless Manufacturing <br /> Vaporless 98LD-2000, 99LD-2000, 99LD-2200, LD-2200 Scout <br /> (for Rigid and Flexible Pipelines) <br /> AUTOMATIC MECHANICAL LINE LEAK DETECTOR <br /> Certification Leak rate of 3.0 gph with PD = 100% and PFA = 0%. <br /> Leak 2.5 gph. <br /> Threshold A pipeline system should not be declared tight if the test result indicates a loss <br /> that equals or exceeds this threshold. <br /> Applicability Gasoline, diesel, aviation fuel. <br /> Other liquids may be tested after consultation with the manufacturer. <br /> Specification System tests pressurized flexible, fiberglass, and steel pipelines. <br /> Tests are conducted at operating pressure. <br /> Pipeline Maximum of 172 gallons for rigid pipelines. <br /> Capacity Maximum of 39.5 gallons for flexible pipelines. <br /> Waiting Time None between dispensing and testing. <br /> None between delivery and testing. <br /> Test Period Response time is less than 1 minute without a leak and 1 to 8 minutes with a <br /> leak. <br /> System Permanent installation on pipeline. <br /> Features Automatic testing of pipeline. <br /> Preset threshold. <br /> Single test to determine if pipeline is leaking. <br /> Restricted flow to dispenser if leak is declared. <br /> Calibration System must be checked annually and, if necessary, calibrated in accordance <br /> with manufacturer's instructions. <br /> Comments Functionality and operability of the 99 LD-2000 and 99 LD-2200 are unchanged <br /> by installation of the Leak Detection Sensor(piston switch) that supports the <br /> VMI ISM-4080 and ISM-4081 Integrated Shutdown Module. <br /> Vaporless Manufacturing Evaluator: Ken Wilcox Associates <br /> 8700 East Long Mesa Drive Tel: (816) 443-2494 <br /> Prescott Valley, AZ 86314 Dates of Evaluation: 05/20/98, <br /> 11/10/98 <br /> Tel: (928) 775-5191 <br />
The URL can be used to link to this page
Your browser does not support the video tag.