COMPLIANCE INFO 2004 - 2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231464
>
COMPLIANCE INFO 2004 - 2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2019 11:58:25 AM
Creation date
12/13/2018 3:43:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2012
RECORD_ID
PR0231464
PE
2361
FACILITY_ID
FA0000914
FACILITY_NAME
TIGER EXPRESS STORES
STREET_NUMBER
1399
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1399 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
456
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-4 - <br />IT IS FURTHER ORDERED that the VST Phase II EVR System shall be compatible with <br />gasoline in common use in California at the time of certification. The VST Phase II EVR <br />System is not compatible with gasoline that has a methanol content greater than 5 percent, <br />an ethanol content greater than 10 percent, or a methyl tert butyl ether (MTBE) content <br />greater than 15 percent. Any modifications to comply with future California gasoline <br />requirements shall be approved in writing by the Executive Officer or Executive Officer <br />delegate. <br />IT IS FURTHER ORDERED that the certification of the VST Phase II EVR System is valid <br />through December 1, 2011. <br />IT IS FURTHER ORDERED that Executive Order VR -203-D issued on October 17, 2008, <br />is hereby superseded by this Executive Order. VST Phase II EVR Systems certified under <br />Executive Order VR -203-A through D may remain in use at existing installations. This <br />Executive Order shall apply to new installations or major modification of Phase II Systems <br />with a throughput of less than or equal to 600,000 gallons per year. Use of this Executive <br />Order for new installations or major modifications at a GDF with a throughput of more than <br />600,000 gallons per year is not authorized. <br />Executed at Sacramento, California, this day of December 2008 <br />&L / oN&. <br />William V. Los , hief <br />Monitoring and Laboratory Divisio <br />Attachments: <br />Exhibit 1 Equipment List <br />Exhibit 2 System Specifications <br />Exhibit 3 Performance Standards and Specifications <br />Exhibit 4 Required Items in Conducting TP -201.3 <br />Exhibit 5 Liquid Removal Test Procedure <br />Exhibit 6 VST ECS Hydrocarbon Sensor Verification Test Procedure <br />Exhibit 7 Warranty <br />Exhibit 8 Vapor Pressure Sensor Verification Test Procedure <br />Exhibit 9 Determination of VST ECS Processor Activation Pressure <br />Exhibit 10 Nozzle Bag Test Procedure <br />Exhibit 11 Veeder-Root Vapor Polisher Operability Test Procedure <br />Exhibit 12 Veeder-Root Vapor Polisher Hydrocarbon Emissions Verification Test <br />Procedure <br />Exhibit 13 Required Items for Conducting TP -201.4 <br />VST Phase 11 EVR System not Including ISD — VR -203-E <br />