<br />CERTIFICATE OF C0MPLIANCF�Y.2, .� .L
<br />Certificate Number 20121101-MH11766.HE*'_IT-114
<br />Report Reference. MH11766-19901.022 P�faA, i 13 ESOE
<br />Issue Date 2012 -NOVEMBER -01
<br />This is to certify that representative samples of the product as specified on this certificate were tested
<br />according to the current UL requirements.
<br />Associated apparatus for use in non -hazardous locations providing intrinsically safe circuit extensions
<br />for use in Class I, Division 1, Group D hazardous locations..
<br />Inventory Measurement System, designated TLS -350 or TLS 350 -PC or TLS -350J, consisting of control
<br />unit Form No. 84709 followed by 0, 5 or 7, followed by 0, 3, 4_5 or 6, followed by 0 or 2, suffixed, 2 or 4;.
<br />or designated TLS -350R or Simplicity consisting of control unit Form No, 84829 followed by 0, 12, 2, 3,
<br />or 5, followed by 0 or 1, followed by 0 or 2, followed by 2 or 4 or designated 4000 consisting of control
<br />unit Form No. 848390, followed by 5 or 8, followed by 00; May be provided with:
<br />Overfill Alarm Form No. 790091-00 with or without an Acknowledgement Switch Form No. 790095-001;
<br />Remote Display Unit, Form No. 8478, followed by 8 or 9, followed by 0, followed by 1 or 2, followed by
<br />1 or 2, followed by 1 or 2. Form No. 847090-1 followed by 0, 1 or 2, followed by 2;
<br />The control unit may be provided_ with a.combination of Plug-in Modules Form Nos. 847490-001; 100,-
<br />101, -102, -103, -104, -105, -106, -109, -110, -111, -202, -204, -206, -207, -208, -209, -210, -300, -301,
<br />302, -303, -304, -305, -306, -309, -315, -316, -317, -326, -327, -340, -350, 360,.-370,-380,400,401,
<br />-410, -420, -430, -431, 480 or Form No. 329359-001, 329360-001, 332250-001 (only one can be
<br />provided), or 332451-001. Form No. 847090-1, control unit may additionally be provided. with Form
<br />Nos. 847490 107 or -108 plug-in modules. Advanced Application Module Form No. 849090 followed by.
<br />5 or 8,. followed. by 00 to 1.6 inclusive and up.to 16 liquid sensors; Form No. 7943 followed by 8 or 9,
<br />followed by 0, followed by -205, -301, 302, -401, -404, 407, -409 or -420;
<br />TLS -RF Console, up to four may be connected to intrinsically safe field wiring terminals but cannot be
<br />placed in the hazardous location.
<br />TLS 350 Console may connect up to 64 of the intrinsically safe apparatus below. These devices have
<br />been evaluated for use in Class I, Division 1, Group D hazardous locations when connected to the
<br />above in accordance with control drawing number 331940-011.
<br />Magnetostrictive probes, Basic Form Nos. 8462, 8463, 8563, 8570; Liquid or Vapor Sensors, Basic
<br />Form Nos. 7943 with or without 80 or 90 maybe be followed by three characters; CCVP, Form No.
<br />861290 -XXX; ISD Flow Meter, Part No. 331847 -XXX or 332374 -XXX; Vapor Pressure Sensor, Part No.
<br />331946 -XXX or. basic Form No. 8611; PressureLine Leak Detectors (PL LD), Basic Form Nos. 8484;
<br />Vacuum Sensors, Form No. 332175 -XXX.; 2 to 1 Sensor Input Boxes, Form No. 857390-102; Oil/Water
<br />Separator Sensor, Basic.Fom No. 7946; UL Listed Submersible Pump, Models PC or PAGC; Mag
<br />Plusl
<br />/� ' 4
<br />William R Carney, Director, North American Certification Programs
<br />UL LLC -
<br />Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of Ut- For questions, please
<br />contact a local UL Customer Service Representative at invw.uLcom/contactus