Laserfiche WebLink
SAN10 A Q U I N Environmental Health Department <br /> COUNTY <br /> F. SYSTEM PIPING CONTINUED: <br /> Check Code <br /> Box Section <br /> HSC Piping compatible with material intended to be stored. <br /> 25290.1 c 1 <br /> 25290.2 c 1 <br /> 23 CCR <br /> bfl 2631(b) Design and construction of piping approved by independent testing organization(e.g. UL). <br /> Piping, including vent lines, sloped toward tank(s)with minimum 1/8 inch slope per 1 foot of run. <br /> 2 290.1 k Vapor recovery, fill riser, and vent line piping are secondarily contained.ppr �., ;y <br /> � 25290.2�c;&Q) , ED <br /> 9 <br /> G. OVERSPILL/OVERFILL PREVENTION: NN O 2018 <br /> Check �-{ <br /> Box section NIVIENTAL HEA <br /> 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> �(1 2635(b) Manufacturer oPw Model 6571EVRB-164042RT052 Oust the bucket is P761 C-FLDV) <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> IXAlert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> ❑ Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity-, and activate an <br /> 2635(b)(2) audible alarm at least five minutes before the tank overfills <br /> Xi Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer OPW Model 71SO-420C for 12'tanks and smaller <br /> Veeder Root VR1-790091-001 Overfill Alarm <br /> Veeder Root VRI-790095-001 Alarm Acknowledgement Switch <br /> H. CORROSION PROTECTION: <br /> Check Code <br /> Box Section <br /> K Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: ❑ Steel with cathodic protection or impressed current <br /> ® 23 CCR ❑ Steel isolated from contact with backfill <br /> 2636(b) <br /> 2 FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: ❑ Sacrificial Anode <br /> 1K 23 CCR 2635(a)(2) ❑ Steel tank with field installed cathodic.protection or impressed <br /> current <br /> ® Tie-downs, when used, constructed of non-corrosive material or coated steel. <br /> 7 of 8 <br />