My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1245
>
2300 - Underground Storage Tank Program
>
PR0541906
>
INSTALL_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/4/2023 4:03:26 PM
Creation date
12/13/2018 4:57:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2019
RECORD_ID
PR0541906
PE
2351
FACILITY_ID
FA0024040
FACILITY_NAME
MANTECA CHEVRON
STREET_NUMBER
1245
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1245 N MAIN ST
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
621
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I..EA01N4r. THE WAY IN FUELING INNOVATION WORLUWIUE <br />Features <br />♦ Contractor -Friendly Installation — <br />Studded mounting ring simply bolts <br />together inside the spill containment <br />bucket. No need to align bolt holes in <br />the manhole cover. <br />♦ Raintight Service — Nitrile gaskets on <br />the manhole and spill bucket mounting <br />rings help prevent contamination of the <br />sump area from surface water intrusion. <br />♦ Highway 20 Load Rating — The <br />rugged diamond plate steel manhole <br />covers, as well as the ductile iron (RT) <br />or aluminum (SC) spill container covers <br />meet H2O Load Rating requirements. <br />♦ Spill Container and Manhole Positive <br />I.D. System — Special recesses <br />cast into spill container covers allow <br />product I.D. tags to be attached to <br />the lids. Matching bucket tags can <br />be affixed to the inside of the spill <br />container to prevent covers from <br />getting switched. <br />♦ CARB Certified — 500 Series <br />CARB EVR Approved Executive <br />Order #VR -102 <br />♦ FillNapor Ports — Configurations are <br />available to accommodate a single fill <br />riser, dual ports for both a fill and <br />vapor riser, and triple and quad ports <br />for multiple fill and vapor risers. <br />Ports can be supplied with or without <br />containment buckets. <br />♦ Port Configurations — Standard port <br />locations match the popular riser <br />spacings (16" or 24") and bung <br />configurations on underground storage <br />tanks. Custom port locations are easily <br />accommodated. For riser spacings less <br />then 16", old style buckets must be used. <br />♦ Manhole Cover Sizes — Standard bolt - <br />down manhole cover diameters of 30" <br />(76 cm), 37" (94 cm), 42" (107 cm), and <br />48" (122 cm) allow ample access to the <br />sump area. Heavy-duty reinforced lid <br />options are also available upon request. <br />♦ Spill Container Cover Options — <br />Standard spill container options include <br />the patented POMECO/OPW dam <br />and groove Raintight (RT) design and <br />the watertight Sealable Cover (SC) <br />"plumber's plug" design. The Raintight <br />cover features a finger -grip lifting facility <br />and an integral seal. The sealable cover <br />features a cam -operated mechanism <br />that expands the seal against the vertical <br />wall of the mounting ring. Both of these <br />water -shedding covers are protected by <br />raised mounting rings. <br />♦ Fastener Options — Two types of <br />fasteners are available to secure the <br />manhole lid and monitoring port <br />to mounting rings. Standard are <br />5/16"-18 hex head bolts. Optional are <br />POMECO/OPW Roto -Lock Fasteners. <br />The POMECO/OPW Roto -Lock system <br />enables a secure, watertight connection <br />without the need to locate threaded bolt <br />holes on the mounting ring. <br />♦ Custom Multi -Port Manholes — Contact <br />your POMECO/OPW representative. <br />♦ Powder Coated Rings & Covers — <br />Available upon request. <br />♦ Replacement Covers — See POMECO <br />Part Number Configurations at <br />www.opw-fc.com. <br />Multi -Port Manhole Water <br />Shroud System Option* <br />The OPW/POMECO Multi -Port Manhole <br />Water Shroud (MPWS) system is desigr <br />to completely isolate surface water. <br />The MPWS features an injection molder <br />fiberglass Water Shroud lid that mates t <br />a standard tank sump top hat reducer. <br />Shroud Boots isolate the spill container <br />buckets using stainless steel band clam <br />which provide a tight seal between the <br />water shroud top hat and the underside <br />of the spill container mounting rings. A E <br />Sump Inspection Port is provided on eaL;tt <br />FRP Cover, allowing full inspection access <br />through the Multi -Port Gauge Port. The <br />OPW/POMECO Water Shroud system is <br />available in 33" and 36" models. The <br />MPWS Water Shroud is sold separately. <br />* Only available for use with post 11103 <br />design "EVR" spill containers. <br />Shroud Boots — <br />Vinyl Plastisol <br />Sump Inspection <br />Port (SIP) — Clear <br />ABS Construction <br />Inspection Port <br />FRP Cover— <br />Injection Molded <br />Fiberglass Cover <br />Important FlexWoda by OPW, Inc., VAPORSAVER- and all other OPW products must be used in compliance with all <br />applicable federal, stale, provincial and local laws, rules and regulations. Product selection must be based on <br />physical specifications and limitations, mmpatibitity wtih the environment and material to be handled. All illustia'a <br />and specifications m this literature are based on the latest production Information avaitable at the t me of pu <br />Prices, materials and specifications ate subject to change at any time, and models may be discontinued al any LZ +� Gj <br />in either case, without notice or obligation. OPW warrants solely to its customer that the following products sold by <br />OPW will be free from defects in materials and worlananship under rornal use and conditions for the periods indicated. <br />x i ; wronmental Systems <br />zeal <br />If:'AAYR,ONN fi : AL t ]`EfILUH <br />TCtIIA i�r�r•rr:.. ^err <br />
The URL can be used to link to this page
Your browser does not support the video tag.