Laserfiche WebLink
Veeder-Root Line Leak Application Guide <br />Selecting a Line Leak Detector <br />This guide helps you to properly configure Veeder-Root's line leak equipment for underground pressurized piping. Note: Fol- <br />lowing the industry's best practices, a containment sensor is recommended for sites with Pressurized Line Leak <br />Detection (DPLLD, PLLD or WPLLD) in the event that the submersible pump develops a leak before the check valve <br />and/or functional element. Line leak detectors only check leaks in the primary product line downstream from the pump. <br />Veeder-Root offers three types of line leak detectors, each uniquely suited to a particular type of application: <br />• DPLLD Digital Pressurized Line Leak Detection <br />• PLLD Pressurized Line Leak Detection <br />• WPLLD Wireless Pressurized Line Leak Detection <br />DPLLD, PLLD and WPLLD eliminate the need to break the product line for installation or service. In addition, WPLLD installs <br />without running new wires. DPLLD, PLLD and WPLLD are the cost-effective choice for most retrofit and new piping installations. <br />Veeder-Root's electronic line leak detectors have been evaluated by a third party in accordance with EPA evaluation proce- <br />dures. Please refer to the National Work Group Listings at www.nwglde.org. <br />FEATURE <br />DPLLD <br />(8590 Series) <br />PLLD <br />(8484 Series) <br />WPLLD <br />(8494 Series) <br />SUPPORTED CONSOLE <br />P20001-3RJ1 - RJ3, AGP200S1 RJ1 - RJ3 (2 HP) YES YES <br />RED JACKET <br />QUANTUM <br />TLS-450PLUS <br />YES <br />NO <br />NO <br />TLS -450 <br />YES <br />NO <br />NO <br />TLS -350 <br />NO <br />YES <br />YES <br />LINE LEAK DETECTION <br />3 gph Testing <br />YES <br />YES <br />YES <br />Precision Testing <br />OPTIONAL <br />OPTIONAL <br />OPTIONAL' <br />Positive Shutdown <br />YES <br />YES <br />YES <br />3rd Party Certified <br />YES <br />YES <br />YES <br />INSTALLATION REQUIREMENTS <br />Requires TLS Console <br />YES <br />YES <br />YES <br />Installs Without Breaking Piping <br />YES <br />YES <br />YES <br />Installs Without New Sump <br />YES <br />YES <br />YES <br />Installs Without New Wires <br />NO <br />NO <br />YES <br />'Not available for flexible piping <br />Line Leak Specifications - Supported Pump Models (Footnotes explained at end of table) <br />FIXED <br />MODELS4-INCH <br />SPEED <br />THE RED JACKET <br />DPLLD/ <br />P75U1RJ1 - RJ3, AGP75S1RJ1 - RJ3 (3/4 HP) YES YES <br />P150U1RJ1 - RJ3, AGP150S1RJ1 - RJ3 (1-1/2 HP) YES YES <br />X3P150U1RJ1 - RJ3, X3AGP150S1RJ1 - RJ3 (1-1/2 HP) YES YES <br />P20001-3RJ1 - RJ3, AGP200S1 RJ1 - RJ3 (2 HP) YES YES <br />RED JACKET <br />QUANTUM <br />P33U1 QS1 - QS3, AGP33S1 QS1 - QS3 (1/3 HP) YES YES <br />P75U1Y QS1 - QS3, AGP75SIY QS1 - QS3 (3/4 HP) YES YES <br />P150UlY QS1 - QS3, AGP150S1Y QS1 - QS3 (1-1/2 HP) YES YES <br />X3P150U1Y QS1 - QS3, X3AGP150S1Y QS1 - QS3 (1-1/2 HP) YES YES <br />X5P150U1Y QS1 - QS3, X5AGP150S1Y QSt - QS3 (1-1/2 HP) NO NO <br />P20001 -3Y QS1 - QS3, AGP200S1-3Y QS1 - QS3 (2 HP) YES YES <br />STANDARD <br />P33R1 T1 - T4 (1/3 HP) YES YES <br />P75S1 T1 - T4 (3/4 HP) YES YES <br />P1 50S1 T1 - T4 (1-1/2 HP) YES YES <br />X3P150S1 T1 - T4 (1-1/2 HP) YES YES <br />X5P150S1 T1 - T4 (1-1/2 HP) NO NO <br />FE PETRO <br />STP33, STPAG33 (1/3 HP) <br />YES <br />YES <br />STP75, STPAG75 (3/4 HP) YES <br />YES <br />STP150, STPAG150, STPAGH150 (1-1/2 HP) YES <br />YES <br />STP200, STPAG200, STPMR200, STPR200 (2 HP) YES <br />YES <br />STPH2O0, STPAGH2O0, STPHMR200, STPHR200 (2 HP) YES <br />YES <br />