My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2019
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
1245
>
2300 - Underground Storage Tank Program
>
PR0541906
>
INSTALL_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/4/2023 4:03:26 PM
Creation date
12/13/2018 4:57:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2019
RECORD_ID
PR0541906
PE
2351
FACILITY_ID
FA0024040
FACILITY_NAME
MANTECA CHEVRON
STREET_NUMBER
1245
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1245 N MAIN ST
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
621
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Veeder-Root Line Leak Application Guide <br />Supported Pipe Types and Line Lengths* - For DPLLD, PLLD and WPLLD (Continued) <br />*lengths approved are for 3.0, 0.2, &0.1 gph line leak tests using single pipe types. For mixed line types with DPLLD or PLLD, see footnote land 6 respectively. <br />TSMAD- DOUBLE WALL <br />1.5 INCH 30-1100 30-1100 No 18900 0.092 <br />2INCH 30-1100 30-650 No 12500 0.163 <br />3INCH 30-749 30-300 No 28200 0.367 <br />TSMAXPD- DOUBLE WALL <br />1.5 INCH 30-1100 30-1100 No 15500 0.092 <br />2INCH 30-1100 30-650 No 9200 0.163 <br />3INCH 30-749 30-300 No 27800 0.367 <br />PETROTECHNIK UPP EXTRA (63 mm) <br />FLEXIBLE PIPE TOTAL CONTAINMENT <br />20-1100 <br />20-650 <br />No <br />11,500 <br />0.163 <br />- <br />ENVIROFLEX RETRACTABLE PIPE <br />PP1500 (1.5 INCH) <br />10-1100 <br />10-1100 <br />10-500 <br />2400 <br />0.092 <br />PP1501(1.5 INCH) <br />10-1100 <br />10-1100 <br />10-500 <br />3500 <br />0.092 <br />PP1502 (1.5 INCH) <br />10-1100 <br />10-1100 <br />No <br />7300 <br />0.092 <br />PP1503 (1.5 INCH) <br />10-1100 <br />10-1100 <br />No <br />2500 <br />0.092 <br />PP2500 AND PP2501 (2.5 INCH) No No No --- --- <br />PP2502 (2.5 INCH ) 10-1078 10-430 No 8700 0.255 <br />PP2503 (2.5 INCH) 10-1078 10-430 No 3100 0.255 <br />OMNIFLEX COAXIAL PIPE <br />CP1501 (1.5 INCH) 10-1100 10-1100 10-500 13,000 0.092 <br />CP1503 (1.5 INCH) 10-1100 10-1100 No 4500 0.092 <br />CP2503 (2.5 INCH) 10-1100 20-430 No 3900 0.255 <br />'Mixed Piping Types with PLLD: Using TLS -350 software Version 23 or later, PLLD is certified for 3 gph-only testing for line volumes up to 212 gallons; and for <br />0.2/0.1 gph testing for line volumes up to 110 gallons. To determine the line volume for mixed piping types, multiply the line length (in feet) times the 'gal- <br />Ions/foot' value for each pipe type and add the results. For example, site has 150 feet of 2" fiberglass and 50 feet of 3" fiberglass pipe: <br />Total line volume = [150 x 0.204] + [50 x 0.461] = 30.6 + 23.1= 53.7 gallons <br />2The 0.2 and 0.1 gph line leak tests cannot be run on flex piping with WPLLD. <br />3Bulk Modulus entry is only applicable to TLS -350 consoles w/software Version 23 or later and all TLS -450 Series consoles. Refer to TLS -350 System Setup <br />manual (P/N 576013-623) or TLS -450 Setup Manual (P/N 576013-940) for programming instructions. <br />4Geoflex piping produced prior to 2001 has a lower bulk modulus than the current product. For this piping (pre -2001) use the values in (). For 2001 piping and <br />later, you must set the correct Bulk Modulus in the "User Defined" menu. <br />5Western Fiberglass COFLEX piping produced prior to 2005 has a different bulk modulus than the current product. For piping produced prior to 2005, use the <br />values in (). <br />61-ine lengths shown represent DPLLD approved lengths for 0.2/0.1 gph testing. 3.0 gph-only testing for DPLLD is certified for line volumes up to 535.6 gal- <br />lons (not to exceed 1100 feet of line. See footnote 1 for instructions on calculating line volume for mixed piping. <br />4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.