Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />FAST N ESY <br />1399 E YOSEMITE AVE, MANTECA <br />June 08. 2016 <br />UST System Observations <br />327 <br />HSC 25298(c) <br />Failed to comply with permanent closure requirements <br />V R -: COS <br />328 <br />CCR 2636(f) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />i i V u R ❑ COS <br />Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />❑ V ❑ R ❑ COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />c V ❑ R ❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />c V ❑ R ❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R o COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />■ V � R ■ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />n V u R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS ll, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />103 <br />HSC 25292.2 Current financial responsibility documents not submitted. <br />Financial responsibility documents have not been submitted to the EHD, the most recent documentation submitted to <br />EHD is dated 9-30-14. Current financial responsibility documents are required to be submitted annually. <br />Immediately log into the California Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/, and upload <br />the required documents. <br />This is a Class II violation. <br />106 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted; no identification of the installed monitoring system <br />components (legend) was included in the submitted map. A site plan must be submitted identifying the locations <br />where monitoring will be performed. Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. <br />This is a Class II violation. <br />112 <br />CCR 2638(d) Failed to submit monitoring system certification test report within 30 days. <br />Annual monitoring system certification, leak detector testing, and spill container testing was performed on 6-11-15 <br />and a test report was submitted on 8-28-25 , more than 1 month late. A copy of the test report must be submitted <br />within 30 days of the tests. Take all necessary precautions to ensure testing and submittal of test reports are <br />performed in a timely manner. <br />This is a Class II violation. <br />Page 3 of 7 <br />