SAMPLING PROTOCOL FOR ROUTINE PIPING/DISPENSER REMOVALIREPLACEMENT <br /> The following represents minimum sampling criterion required for closure compliance. Soil samples collected shall be <br /> representative of native soils beneath the tank's invert(tank's bottom) at a collection depth not to exceed 2 -4 feet. Samples <br /> cannot be combined into a composite sample for analysis in the field or the lab. Each sample must have a set of <br /> corresponding analytical results. If contamination is documented during closure,an Unauthorized Release Notification must be <br /> completed and submitted within five(5)working days pursuant to California Health&Safety Code, Section 25295. <br /> DISPENSER PIPING AND STOCKPILE SAMPLES ' <br /> DISPENSER SAMPLES 1 Sample beneath each disper� ��.l <br /> PIPING SOIL SAMPLES 1 Sample every 20 lineal feet JUL 12 20 <br /> DISPENSER&PIPING STOCKPILE SAMPLES 2 Samples every 50 cubic yards <br /> AL <br /> HFAI_TH QFPAAPTMENT <br /> TABLE #2 RECOMMENDED MINIMUM VERIFICATION ANALYSES <br /> FOR UNDERGROUND STORAGE TANK INVESTIGATIONS <br /> TANK TANK Gasoline Diesel BTEX VOCs0) Semi- oil& PCB Total Title 21 <br /> # CONTENTS VOCs(2) Grease Lead Metals(3) <br /> 8015M 8021B 82608 8082 7421 <br /> 82608 8015M 8260B 8270C 1664A <br /> Unknown Fuel X X X X <br /> (C4-C36) <br /> Gasoline <br /> (C4-C20) X X X <br /> Diesel X X X <br /> (C10—C36} <br /> Jet Fuel/Kerosene <br /> (C9-C20) X X <br /> Heating oil X X <br /> (CIO-C32) <br /> Stoddard Solvent <br /> (non-chiodnated) X X <br /> C8-C20 <br /> Chlorinated X X <br /> Solvents <br /> Waste Oil or X X X X X X X <br /> Unknown Contents <br /> Notes: <br /> 1. EPA Method 8260E analyses must include all analytes listed in the method plus fuel oxygenates methyl- <br /> tertiary-butyl ether(MTBE),diisopropyl ether(DIPE), ethyl-tertiary-butyl ether(EtBE),tertiary-amyl-methyl <br /> ether(TAME), tertiary-butanol(TBA),methanol and ethanol and fuel additives 1,2-dichloroethane(1,2-DCA) <br /> and ethylene dibromide(EDB or 1,2-dibromcethane). <br /> 2. If pentachlorophenol(PCP)is identified, analyze the soil and/or water sample for dioxins and furans by EPA <br /> Method 8290 and pesticides by EPA Method 8081A. <br /> 3. Title 22 Metals: Method 60108 may be used for all but the following metals,for which individual AA methods <br /> are required:Antimony&Arsenic by 7062, Cadmium by 7131A, Lead by 7421, Mercury by 7471A, Nickel by <br /> 7521, Selenium by 7742, and Thallium by 7841. <br /> 4. Non-proprietary, performance based analytical methods may be used with approval of Regional Board staff. <br /> EH230038(revised 12-11-15) 5 <br />