Laserfiche WebLink
r , <br />FLOAT SIZE: <br />WATER WARNING <br />HIGH WATER LIMIT: <br />MAX OR LABEL VOL: <br />OVERFILL LIMIT . <br />HIGH PRODUCT <br />DELIVERY LIMIT <br />4.0 IN. <br />1.0 <br />2.0 <br />9728 <br />90% <br />8755 <br />95% <br />9241 <br />10% <br />972 <br />LOW PRODUCT <br />531 <br />LEAK ALARM LIMIT: <br />99 <br />SUDDEN LOSS LIMIT: <br />99 <br />TANK TILT <br />1.10 <br />PROBE OFFSET <br />0.00 <br />MANIFOLDED TANKS <br />TO: NONE <br />LEAK MIN PERIODIC: 0% <br />0 <br />LEAK C°1I hd AP-INUAL 0% <br />0 <br />PERIODIC TEST TYPE <br />STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM°DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 3 MIN <br />PUMP THRESHOLD 10.00% <br />LEAK TEST METHOD <br />TEST ON DATE : ALL TANK <br />JAN 1, 1996 <br />START TIME : DISABLED <br />TEST RATE :0.20 GAL/HR <br />DURATION : 2 HOURS <br />TST EARLY STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />,IQUID SENSOR SETUP <br />L 1:DISP 1-2 <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 2:DISP 3-4 <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 3:DISP 5-6 <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 4:DISP 7-8 <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 5:DIESEL STP <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 6:DIESEL ANNULAR <br />DUAL FLOAT HYDROSTATIC <br />CATEGORY.' : ANNULAR SPACE <br />L 7:87 STP <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 8:87 ANNULAR <br />DUAL FLOAT HYDROSTATIC <br />CATEGORY : ANNULAR SPACE <br />L 9:91 STP <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />1-10:91 ANNULAR <br />DUAL FLOAT HYDROSTATIC <br />CATEGORY : ANNULAR SPACE <br />OUTPUT RELAY SETUP <br />R 1:87 TURBIN <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />IN—TANK ALARMS <br />T 2:HIGH WATER ALARM <br />T 2:LOW PRODUCT ALARM <br />'IQUID SENSOR ALMS <br />L <br />1:FUEL ALARM <br />L <br />2:FUEL ALARM <br />L <br />3:FUEL ALARM <br />L <br />4:FUEL ALARM <br />L <br />7:FUEL ALARM <br />L <br />1:SENSOR OUT <br />ALARM <br />L <br />2:SENSOR OUT <br />ALARM <br />L <br />3:SENSOR OUT <br />ALARM <br />L <br />4:SENSOR OUT <br />ALARM <br />L. <br />7:SENSOR OUT <br />ALARM <br />R 2:91 TURBIN <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />IN—TANK ALARMS <br />T 3:HIGH WATER ALARM <br />T 3:LOW PRODUCT ALARM <br />LIQUID SENSOR ALMS <br />L <br />1:FUEL ALARM <br />L <br />2:FUEL ALARM <br />L <br />3:FUEL ALARM <br />L <br />4:FUEL ALARM <br />L <br />9 :FUEL ALARA <br />L <br />1:SENSOR OUT <br />ALARM <br />L <br />2:SENSOR OUT <br />ALARM <br />L <br />3:SENSOR OUT <br />ALARM <br />L <br />4:SENSOR OUT <br />ALARM <br />L <br />9:SENSOR OUT <br />ALARM <br />R 3:DIESEL TURBIN <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />IN—TANK ALARMS <br />T 1:HIGH WATER ALARM <br />T 1:LOW PRODUCT ALARM <br />LIQUID SENSOR ALMS <br />L 1:FUEL ALARM <br />L 2:FUEL ALARM <br />L 3:FUEL ALARM <br />L 4:FUEL ALARM <br />L 5 :FUEL ALARM <br />L 1:SENSOR OUT -ALARM <br />i L 2:SENSOR OUT ALARM <br />L 3:SENSOR OUT ALARM <br />L 4:SENSOR OUT ALARM <br />L 5:SENSOR OUT.ALARM <br />RECONCILIATION SETUP <br />AUTOMATIC DAILY CLOSING <br />TIME: 2:00 ANI <br />PERIODIC RECONCILIATION <br />MODE: MONTHLY <br />TEMP COMPENSATION <br />STANDARD <br />BUS SLOT FUEL METER TANK <br />— — — — — <br />TANK MAP EMPTY <br />