Laserfiche WebLink
AUG 12 2013 <br />SWRCB, January 2002 Page of <br />7. UNDER -DISPENSER CONTAINMENT (UDCI TESTING ENVIRONMENT <br />Test Method Developed By: ❑ UDC Manufacturer ❑ Industry Standard X Professional Engineer <br />Other (Specify) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Caldwell Level Change Indicator Equipment Resolution: .002 <br />UDC Manufacturer: <br />UDC # 1&2 <br />UDC # 3&4 UDC # 5&6 <br />UDC # 7&8 <br />Total Containment <br />Total Containment Total Containment <br />Total Containment <br />UDC Material: <br />Poly <br />Poly Poly <br />Poly <br />UDC Depth: <br />27" <br />27" 28" <br />27" <br />Height from UDC Bottom to Top <br />of Highest Piping Penetration: <br />13 %" <br />13" 13 %" <br />13 %" <br />Height from UDC Bottom to <br />Lowest Electrical Penetration: <br />7 ''/2" <br />7" 10 %" <br />12" <br />Condition of UDC prior to <br />testing: <br />Dry <br />Dry Dry <br />Dry <br />Portion of UDC Tested <br />Water Level 16" <br />Water Level 16" Water Level 16" <br />Water Level 16" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?` <br />Yes <br />Yes Yes <br />Yes <br />Turbine shutdown response time <br />Not Alarmed <br />Not Alarmed Not Alarmed <br />Not Alarmed <br />Is system programmed for fail- <br />safe shutdown?* <br />Yes <br />Yes Yes <br />Yes <br />Was fail-safe verified to be <br />operational?* <br />No <br />No No <br />No <br />Wait time between applying <br />water and starting test <br />10 Minutes <br />10 Minutes 10 Minutes <br />10 Minutes <br />Test Start Time: <br />10:25 <br />10:30 11:15 <br />11:20 <br />Initial Reading (R,): <br />.001 <br />.001 .001 <br />.001 <br />Test End Time: <br />10:55 <br />11:00 11:45 <br />11:50 <br />Final Reading (RF): <br />.001 <br />.001 .001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes 30 Minutes <br />30 Minutes <br />Change in Reading (RF -R,): <br />0 <br />0 0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />.005/30 Minutes .005/30 Minutes <br />.005/30 Minutes <br />Test Result: <br />X Pass ❑ Fail <br />X Pass ❑ Fail X Pass ❑ Fail <br />X Pass ❑ Fail <br />Was sensor removed for testing? <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testing? <br />X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA X Yes ❑ No ❑ NA <br />X Yes ❑ No ❑ NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />