YOSEMITE
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231464
>
COMPLIANCE INFO_2013 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/5/2019 9:11:29 AM
Creation date
12/14/2018 4:34:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013 - 2018
RECORD_ID
PR0231464
PE
2361
FACILITY_ID
FA0000914
FACILITY_NAME
TIGER EXPRESS STORES
STREET_NUMBER
1399
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1399 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
422
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.s*gov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility <br />Fast and Easy #16 <br />VIOLATIONS <br />Facility <br />1399 Yosemite Avenue, Manteca <br />Inspection <br />Jun 27, 2013 <br />Name: <br />M <br />Address: <br />HSC = California Health and Safety Code; CCR = California Code of Regulations <br />Date: <br />Facility t: Supandeep Singh <br />File Review <br />101 HSC 25284 <br />Title: Manager <br />102 HSC 25404.5 <br />Phone: (209)823-3460 <br />Inspection XRoutine Monitoring System Certification , Installation ❑ Complaint- ID# <br />Type: <br />t I Other: <br />(Authority HSC 25289) <br />Singh <br />105 X CCR 2711 <br />Consent for. X inspection a Sampling Photos <br />106 CCR 2632(b) <br />Granted by:Supandeep <br />Title: <br />Monitoring <br />Panel: <br />Piping <br />System: <br />D(Pressurized _Suction ❑Gravity <br />Overfill <br />Prevention: <br />XMechanical Audible/visual <br />UST5 <br />Annual line leak detector test not performed (M1) <br />6 <br />7 <br />- - <br />----- <br />- - <br />- - <br />114 CCR 2715(b) <br />Designated operator does not possess a current ICC CA UST System Operator certification <br />115 CCR 2660(k) <br />Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />--Product --------- <br />--87-octane - <br />- 91 octane - <br />-_--DSL <br />118 HSC 25286(a) <br />I Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) <br />Permit to temporarily close UST system not obtained <br />120 HSC 25298(c) <br />Permit to dose UST system not obtained <br />On Site Records <br />Designated <br />None <br />ICC Exp. <br />202 X CCR 2712(1) <br />Violations: M1 -Release Detection <br />C M2 -Release Prevention ❑ M3 - Both <br />operator. <br />Date: <br />On Site Service <br />ICC Exp. <br />Manufacturer's <br />Technician: <br />Date: <br />Training: <br />Inspector Received By: Title: <br />0. <br />T INSPECTION REPOR <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = California Health and Safety Code; CCR = California Code of Regulations <br />CI = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />File Review <br />101 HSC 25284 <br />No permit to operate <br />102 HSC 25404.5 <br />Annual operating fees not paid <br />103 HSC 25284(a)(3) <br />No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 X HSC 25292.2 <br />Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 X CCR 2711 <br />Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 CCR 2632(b) <br />Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 CCR 2632(d)(1)(C) <br />Plot planlsite map not submitted or fails to completely show where monitoring is performed <br />108 X CCR 2637 <br />Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test notification <br />not provided to the EHD at least 48 hours prior to conducting the test <br />109 X CCR 2638 <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />(e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />110 HSC 25291(f) <br />Annual line leak detector test not performed (M1) <br />111 HSC 25284.2 <br />Annual spill containment testing not performed <br />112 CCR 2636(f)(4) <br />Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br />113 CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />114 CCR 2715(b) <br />Designated operator does not possess a current ICC CA UST System Operator certification <br />115 CCR 2660(k) <br />Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />116 HSC 25292.5 <br />Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 CCR 2661 <br />Permit to repair UST system not obtained <br />118 HSC 25286(a) <br />I Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) <br />Permit to temporarily close UST system not obtained <br />120 HSC 25298(c) <br />Permit to dose UST system not obtained <br />On Site Records <br />201 X CCR 2712(b) <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6 1% years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 X CCR 2712(1) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />203 CCR 2650 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />was not recorded; (e) escaped secondary containment, not deaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />Inspector Received By: Title: <br />0. <br />T INSPECTION REPOR <br />
The URL can be used to link to this page
Your browser does not support the video tag.