My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2420
>
2300 - Underground Storage Tank Program
>
PR0231580
>
COMPLIANCE INFO 2012 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2021 2:41:11 PM
Creation date
12/21/2018 3:49:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2017
RECORD_ID
PR0231580
PE
2361
FACILITY_ID
FA0003963
FACILITY_NAME
TRACY76
STREET_NUMBER
2420
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
Tracy
Zip
95377
APN
23802006
CURRENT_STATUS
01
SITE_LOCATION
2420 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
280
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MOI'+tA <br />RING SYSTEM CERTIFI ATION <br />For Use By All Jurisdictions Within the State of California <br />Authority Cited.- Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br />This font] most be uscd to dvluurcfrt testing turd servicing of monitoring equipment. I <br />the faeilA separate certification or report must be prepared for each monitorine system control panel by the technician who performs the work. <br />A copy of this form must be provided to the tank system owner/operator. The owner/operator must submit a copy of this form to the local agency <br />regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: GXco-k I ru, 7 (o <br />Bldg. No.: <br />SiteAddfoss: ao GwNi ,lrtc k8. <br />City: / Zip: <br />Facility Contact Person: CV, t � <br />Contact Phone No.: <br />Make/Model of Monitoring System: ('r,\ Ili � .�� ,� 1.=t'IC_ <br />B. Inventory of Equipment Tested/Certified <br />Date of T ' (3 <br />NOIilAN3 = <br />JuNnOO Nlnovor turfs 2� <br />Check the Oppropriate boles to indicatespecific equipment ins ected/servicede: r <br />Ta"k iii: B7 <br />Tank ID: <br />❑ In -Tank Gauging Probe. Model: <br />9Annular Space or Vault Sensor, Model: <br />"Piping <br />❑ In -Tank Gauging Probe. l: <br />Annular Space or Vault <br />(11r;r <br />Sump / Trench Sensor(s). Model:_ <br />c _It I <br />❑ Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />,01ft.cffianical Line Leak Detector. Model: }�1 L.�aO(1� <br />(Mechanical Line Leak Detector. Model:, }/fl�Lfl71Db17 <br />❑ e,jectronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ <br />LI Tank Gvertill / High -Level Sensor. Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: k � <br />Tank ID: <br />❑ Ill Tank ^ `._, _'::I' <br />Annular Space or Vault Sensor. Model: `— <br />❑ L.-.. a uuubaur, i'.�.lG. Model: <br />C3 Annular Space or Vault Sensor. Model: <br />J9 Piping Sump / Trench Sensor(s). Model: <br />Piping Sump / Trench Sensor(s). Model: <br />a Fill Surup Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model; <br />iii.ri + LL) Xj1(� <br />❑ Electronic Line Leak Detector. Model: <br />❑ Mechanical Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />[]'Tank Overfill / High -Level Sensor. Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: lv-a <br />Dispenser ID: -�-Q <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ Dispenser Containment•Sensor(s). Model: <br />Shear Valve(s). <br />[aShear Valve(s). <br />Dispac. Cvuiauai.oui Fiva:(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: r <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ Dispenser Containment Sensor(s). Model: <br />Shear Valvo(s). <br />Shear Valve(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s). Model; <br />[] Dispenser Containment Sensor(s). Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />•If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility <br />C. Certification - I certify that the equipment identified In this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Site -Plot Plan showing the layout of monitoring equipment. For any egyr went capable of generatin such reports, I have <br />also attached a copy of the report; (check all that apply): System set-up [Alarm history reportvet�'�U <br />Technician Name (print): Tony Fontana Signature: <br />Certification No.: V.R. A23686 ICC 5289227 -UT License. No.: A- 84628 <br />Testing Company Name: U.S.T. Compliance Testing Inc. Phone No.: (209) 595-4489 <br />Testing Company Address: P.O. Box 580 Ceres, CA 95307 Date of Testing/Servicing: -13 <br />UN -036 —1/6 www.unidocs.org Rev. 01/17/08 <br />
The URL can be used to link to this page
Your browser does not support the video tag.