My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012 - 2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2420
>
2300 - Underground Storage Tank Program
>
PR0231580
>
COMPLIANCE INFO 2012 - 2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/23/2021 2:41:11 PM
Creation date
12/21/2018 3:49:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012 - 2017
RECORD_ID
PR0231580
PE
2361
FACILITY_ID
FA0003963
FACILITY_NAME
TRACY76
STREET_NUMBER
2420
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
Tracy
Zip
95377
APN
23802006
CURRENT_STATUS
01
SITE_LOCATION
2420 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
280
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Trac 76 Facility Insp <br />2420 West Grant Line Road, Tracy Dateection <br />Name: y Address: May 22, 2013 <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation, C2 = Class 2 violation: M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR -Notice to Comply) <br />UST Inspection: Routine & Annual Monitoring System Certification <br />104. Financial responsibility documents for 2013 year have not been submitted to the EHD. Current <br />financial responsibility documents are required to be submitted annually. Complete and submit a copy <br />of the financial responsibility to EHD or submit copy online to CERS. <br />305. The center Bravo float in Dispenser 1/2 sump failed to stop the flow of product at the dispenser <br />when tested. All monitoring equipment shall be maintained to activate an audible and visual alarm or <br />stop the flow of product at the dispenser when it detects a leak. Correct immediately by having a <br />properly licensed, trained, and certified contractor replace the failed component with a functional <br />component (LG 113-x listed, if applicable). <br />-Corrected on site. Technician removed liquid from Bravo float, reinstalled and retested- passed. <br />Submit to SJC EHD within 30 days (06/24/13): <br />1. one copy of the completed "Return to Compliance Certification" form <br />2. a written corrective action statement for each of the above violations <br />3. copy of financial responsibility to EHD or online to CERS <br />Notes: <br />-Facility has not submitted CUPA data online (Business Plans, Hazardous Material, Underground <br />Storage Tanks, Emergency Response, Training,etc) to California Electronic Reporting System <br />http://cers.calepa.ca.gov Facility CERS ID is 10181551. <br />Please contact Thuy Tran, ph 468-8257, to make an appointment for assistance on online reporting <br />-Site officially open in Sept 2012 after the construction/ repairs completed. <br />-Programing setup change. When performed initial sensor out, the alarm printout 'fuel alarm' instead of <br />sensor out'. Reviewing monitoring system liquid level setup, liquid sensors incorrectly programmed to be <br />normally closed'. Technician reversely installed the magnetic float sensors in annulars and STPs, then <br />reprogrammed liquid sensor set up from 'normally closed' to 'tri-state (single float)'. When retesting <br />sensor out, the alarm printout correctly documents 'sensor out'. <br />-Received MC,LD,SB test results for today on site from technician- all passed. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Inspector.Received <br />By. <br />Title: <br />EHD 23-02 Rev 04/19/12 0 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.