Laserfiche WebLink
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd/unitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />FacilityInspection <br />Name: y 76 <br />Facility 2420 W Grantline Road, Tracy <br />TAddress:Trac <br />May 17, 2012 <br />Dae: <br />Facility <br />Jivtesh Gill <br />Title: <br />Operator <br />rPM) 481 7445 <br />Contact: <br />Inspection <br />Type: XRoutine XMonitoring System Certification I I Installation Complaint - ID#: Other: <br />(Authority HSC 25289) <br />Jivtesh GIII Operator <br />Consent for: Xlnspection XSampling XPhotos Granted by: Title: <br />Monitoring <br />Panel: TLS -350 <br />PipiVeeder-Root <br />System: <br />System: XPressurized I I Suction I I Gravityprevention <br />Overfill <br />XMechanical I I Audible/visual <br />UST <br />45 <br />6 <br />Product --- <br />--------87octane - <br />-- 91 -octane -- <br />----------- <br />- -DSL- <br />----- <br />-------- - - <br />- - - - - - - <br />-------------- <br />------ --- - <br />------------ - <br />Designated ICC Exp. <br />Operator: Date: <br />Violations: XM1-Release Detection M2 -Release Prevention i i M3 - Both <br />site service Curtis Carpenter ICCDat Exp. 7/28/12 Manufacturer's <br />p VR - 1/6/13 and VMI - 12/6/12 <br />Technician: Date: Training: <br />VIOLATIONS <br /># <br />I C1 <br />C2 <br />M <br />I Code Section <br />HSC = California Health and Safety Code; CCR = California Code of Regulations <br />Cl = Class 1 violation, C2 = Class 2 violation, M = Minor violation <br />File Review <br />101 HSC 25284 No permit to operate <br />102 HSC 25404.5 Annual operating fees not paid <br />103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 X HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 X CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 X CCR 2632(b) Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 CCR 2637 Secondary containment: (a) test not performed; (e) test report not submitted within 30 days, (f) test notification <br />not provided to the EHD at least 48 hours prior to conducting the test <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />109 CCR 2638 (e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />110 HSC 25291 (1) Annual line leak detector test not performed (Mt) <br />111 HSC 25284.2 Annual spill containment testing not performed <br />112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br />113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br />114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br />Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />115 CCR 2660(k) permit conditions <br />Enhanced leak detection (ELD) testing not performed on a system located within 1 000'of public well, or <br />116 HSC 25292.5 <br />failures not repaired and retested <br />117 CCR 2661 Permit to repair UST system not obtained <br />118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) Permit to temporarily close UST system not obtained <br />120 HSC 25298(c) Permit to close UST system not obtained <br />On Site Records <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/z years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling, <br />201 <br />CCR 2712(b) <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 <br />X <br />CCR 2712(i) Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />203 <br />CCR 2650 was not recorded, (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />product was not reported to the EHD within 24 hours <br />Inspector Received By. Title: <br />Muniappa Naidu (209) 468-3439 <br />EHD 23-02 Rev 09101/11 Page 1 UST INSPECTION REPORT <br />