Laserfiche WebLink
1 <br /> TABLE 4 <br /> VAPOR EXTRACTION PILOT TEST DATA <br /> 1 <br /> MONITORING WELL-1B <br /> ' 1399 EAST YOSEMITE AVENUE <br /> MANTECA, CALIFORNIA <br /> System Parameters: <br /> Average intake airflow 88 00 Cfm <br /> Average intake pressure -0 614 psi <br /> ' Average intake temperature 73 deg F <br /> Average exhaust airflow 99 00 Cfm <br /> Average exhaust pressure 0105 psi <br /> ' Average exhaust temperature 120 deg F <br /> Constituent Extraction in pounds per day (24 hours): <br /> ' TPH-Gasoline 481749 <br /> Benzene 05129 <br /> Ethylbenzene 15551 <br /> Toluene 31027 <br /> Total Xylenes 76863 <br /> ' Total Pounds/Day 61.0319 <br /> 1 <br /> 1 <br /> NOTE The constituent results presented are based on the analytical results in Appendix C <br /> Aegis Environmental Inc <br /> ' May 12 1992 <br /> 1 _ <br />