Laserfiche WebLink
Quarterly Groundwater Monitoring,Remediation Status Report& <br /> g P <br /> Sod Boring Verification Workplan <br /> Moore Petroleum,Inc, 1399E Yosemite Ave,Manteca,CA <br /> March 26, 1996 <br /> Page 3 <br /> ' horizontal piping (HORM) and filters the vapors through two in-brie 2001b carbon absorption <br /> filters prior to atmospheric release The carbon absorption vapor extraction system was started <br /> on July 5, 1995 and operated continuously through August 4, 1995, at which time vapor <br /> hydrocarbons concentrations fell below laboratory detection hmrts System operating data is <br /> contained in Table 3 Table 4 contains calculated daily extraction rates based on laboratory <br /> tanalytical reports for the vapor extraction system. <br /> From August 1995 through December 1995, the soil vapor extraction system was in a pulse mode <br /> where the system is turned on and vapor readings are recorded with a flame ionization detector <br /> (FID) on a monthly basis If petroleum concentrations are zero on the FID, then the system is <br /> i turned off The purpose of this monthly pulsing was to extract any remaining hydrocarbon vapors <br /> in the surrounding soils, if any Table 5A through 5E contains monthly system pulse data On <br /> December 19, 1995, no hydrocarbon vapors were detected from either MW-1B or from the <br /> ' honzontalpiping Asa result of the lack of hydrocarbon vapors, the vapor extraction system was <br /> permanently turned off on this date <br /> VERIFICATION SOIDL BORINGS <br /> Apex proposes to drill two angle soil borings(VSB-1 and VSB-2)for the purpose of verifying the <br /> i absence of petroleum impacted soil beneath the former tank basin Figure 4 shows the locations <br /> of the two proposed angle soil borings <br /> ' The two proposed verification soil borings will be drilled at an angle of 30 degrees measured from <br /> vertical Sort sampling will begin at 15 feet of drilled depth, which is 12 feet below grade Soil <br /> samples will be collected at drilled depth of 15, 20 and 25 feet This corresponds to 12, 16 and 20 <br /> feet below grade The sic soil samples, three from each boring, will be analyzed for TPK as <br /> gasoline, and BTEX <br /> RECOMMENDATIONS <br /> All groundwater samples collected from the six monitoring wells located at the subject site have <br /> not contained detectable levels of TPI, as gasoline, or BTEX for the last three quarters All six <br /> on-site wells will be quarterly sampled for 1 more quarter in.the month of May 1996 If quarterly <br /> sampling results and verification soil boring samples are below laboratory detection limits for <br /> TPH, as gasoline, and BTEX, Apex will then request site closure <br /> i <br />