Laserfiche WebLink
CC OAKLRNO <br /> 8810197TWP CON--1 <br /> TECHNICAL WORK PLAN <br /> ENVIRONMENTAL SIVE ASSESSMENT AT <br /> INDY ELECTRONICS, INC. , PROPERTY <br /> Manteca, California <br /> Indy Electronics, Inc. is a semiconductor industry manufacturing company <br /> located at 400 Industrial Park Drive in Manteca, California. Manufacturing <br /> activities at the plant include tiro electroplating and solder dipping for <br /> plastic and ceramic integrated circuit devices. <br /> The site is approximately 11-1/2 acres located between Industrial Park <br /> Drive and Vanderbilt Circle in the Manteca Industrial Park. About 8 acres <br /> are developed with Indy Electronics plant buildings and paved parking <br /> areas, and about 3-1/2 acres are undeveloped land at the east side of the <br /> site. <br /> Existing plant buildings include a 150-by-460 foot main plant manufacturing <br /> building, a 70-by-120 foot tool and die building, a 25-by-50 foot chemical <br /> warehouse and a 30-by-15 foot storage building. These buildings were <br /> constructed about 1980. <br /> The geologic region is underlain by deep alluvial soils with ground water <br /> at shallow depths. The ground-water table at the site is believed to be at <br /> a depth less than about 30 feet. An 1,800 gallon--per-minute municipal <br /> water supply well (Well No. 13) is located adjacent to the south side of <br /> the site. for this property, WCC proposes to perform an Environmental <br /> Assessment using information to be obtained from a limited program of soil <br /> borings, ground-water monitoring well installations and surface soil <br /> sampling, including chemical analyses of soil and ground-water samples. <br />