11" <br /> V-7" H <br /> EMERGENCY SWITCH PARTS AND SIGN Z <br /> SUPPLIED BY 7-ELEVEN, INC.AND W <br /> ° ° VERTICAL SEALING g <br /> INSTALLED BY GAS CONTRACTOR 2 <br /> RIGID CONDUIT o O H <br /> 000000000°p0000°pop fl. W W <br /> MagVFC ° ° ° ° ° ° ° ° 00 z <br /> °°°p°°°°°°°°°°°°°°° SEALING COMPOUND USE COMPOUND ;. � EMYS CONDUIT 1'-01, 'c <br /> °o°o°o°00000°0°0°0° SEAL FITTING (XP) W � <br /> MADE BY MANUFACTURER OF SEAL 0 O <br /> FITTING SIGN 01 0 , <br /> (WHITE W/RED EMERGENCY W �- <br /> LETTERING) SHUT OFF �' 1= <br /> PUSH CONDUCTORS AWAY FROM THE FILLING a U <br /> OPENING & FORCE THEM APART SO THEY DO SWITCH 00 00 <br /> NOT LIE IN CONTACT WITH EACH OTHER ALONG i PACKED FIBER No No <br /> DAM <br /> THEIR LENGTH PUSH SHREDS OF PACKING COVER o o <br /> m <br /> AWAY FROM THE CONDUCTOR TO PREVENT (SAFETY TECHNOLOGY � <br /> GAS LEAKAGE PATHS INTERNATIONAL, INC. PART NO. IA-ESOCA T-RD(RED)NOTE : 0c�LARGE MUSHROOM HEAD Proto 08-21-17 <br /> PROVIDE EXPLOSION PROOF SEALS. IN ACCORDANCE WITH ARTICLE 501, CLASS 1, z <br /> DIVISION 2 OF THE LATEST NATIONAL ELECTRICAL CODE TYPICAL FOR ALL EMERGENCY STOP BUTTON > <br /> dCONTACT ACTUATOR) <br /> UNDERGROUND CONDUIT STUB-UPS INTO EQUIPMENT ( IJFT ERE a <br /> 0 OO O <br /> SEAL OFF ALL CONDUIT ENTERING OR LEAVING CAVITIES OR ENCLOSURES OF p 1 <br /> DISPENSERS AND ASSOCIATED EQUIPMENT. IN ADDITION, ALL CONDUITS COMING ~ Q <br /> FRONT VIEW SIDE VIEW FROM THE BUILDING THROUGH A HAZARDOUS LOCATION ALSO REQUIRE °' < cp <br /> � w <br /> SEAL-OFFS AT BOTH ENDS. oo Lo <br /> W r J <br /> FE PETRO MAGVFC-VARIABLE Oa Q <br /> FREQUENCY CONTROLLER. SEE MANUAL M 2 U <br /> FOR WIRING INSTRUCTIONS. d <br /> Lu Z AWN U <br /> Z ()f � W <br /> 4 MAG VFC DETAIL SEAL FITTING INSTALLATION zo w � UJ <br /> 3 NTS 2 EM ERCEN CY SHUT OFF W COVER > o zo o w <br /> Ill <br /> J } VU Z � <br /> W tQ <br /> o <br /> W N � J <br /> 0 U <br /> U) <br /> 0 <br /> 0 <br /> N <br /> EMT CONDUIT co <br /> a <br /> SIZE AND QUANTITY OF CONDUITS <br /> k co ARE FOR REFERENCE ONLY. <br /> w <br /> O <br /> F- <br /> ELECTRICAL ROOM CEILING <br /> (ACTUAL LAYOUT MAY VARY <br /> TO MEET SITE CONDITIONS) <br /> STORE CONTRACTOR: <br /> INSTALL CONDUIT FROM THE ELECTRICAL <br /> ROOM GUTTERS TO 5'-0" PAST THE FRONT <br /> SIDEWALK. SEE SPECIFICATION SHEET G16.0, MAG MAG EMS <br /> SECTION VII, 2.3.1 FOR CONDUIT TYPES. <br /> FUELING CONTRACTOR: VFC VFC CP_l I <br /> EXTEND CONDUITS FROM 5'-0" PAST THE 3 POLE 100 AMP 01 STP 01 <br /> FRONT SIDEWALK TO FINAL TERMINATION CBS of 0 <br /> w R <br /> POINT. SEE SPECIFICATION SHEET G16.0, <br /> CONTACTOR pNow <br /> SECa , <br /> TION VII, 2.3.1 FOR CONDUIT TYPES. Lu <br /> w F am z <br /> > 0 p <br /> O_ � W12 <br /> O a F. <br /> ui <br /> r <br /> 0 } <br /> WIRE WAY TO SALES <br /> COUNTER <br /> 0 <br /> REF STORE <br /> SUPPLIED BY I w <br /> E1.1 SHEET STORE NEW 7-ELEVEN <br /> FOR PANEL PANEL PANEL J 4 <br /> INFORMATION F <br /> STP DBOX I (C) 0 00 (3 J <br /> IR J10 o Lo Z <br /> TYP 3 00 O `- Z ~ <br /> Z O <br /> Q m <br /> STP STP m <br /> IR IR 0 zjj c) <br /> cn O U <br /> !Vl <br /> 2WIRE WAYWIRE WAY WIRE WAY WIRE WAY � moE °r x - vc c <br /> 2 ,6O NE <br /> O.NwL c0 ...�+=. NNC N <br /> >," 3doam_C00m � � a)� a � oEE <br /> p O T 'o0 <br /> w E t ° � �'v z I a- <br /> U 1- d w w GO Q .-J 0 E nor o Y =E <br /> Q = 0 W K F- i50Nco= 3(DC E <br /> LD Q0 0 0 = <br /> U w a a z a of <br /> a (D w a COw w � <br /> 0z U) rn z z �F5t1 <br /> a L) c w i w tF <br /> co co � ...� <br /> Lu <br /> til <br /> a) - X5558 <br /> 0 <br /> PSOWER DATA EQUIPMENT DETAILS ' ` <br /> 11/26/18 <br /> SHEET: <br /> G10 . 0 <br /> FUELING - USA <br />