Laserfiche WebLink
Veeder-Roof Sensor Application Guide <br />Mag Sump Sensor <br />The discriminating Mag Sump Sensor detects the presence and amount of water and/or fuel in the containment sump or dis- <br />penser pan. Using proven magnetostrictive technology, Veeder-Root's Mag Sump Sensor produces fast reaction and recovery <br />times, which eliminates costly and unwarranted service calls and sensor replacements. And where it's allowed, stations can <br />remain open when only water is detected. <br />Table 2. Mag Sump Sensor Features and Console Compatibility <br />Item <br />Description <br />Form Number <br />See Table 3 below <br />Operating principle <br />Magnetostrictive probe with dual floats <br />Product activation <br />height' <br />1.368" (3.47cm), gasoline; 1.614" (4.1cm), water; 1.116" (2.83cm) gasoline on 7 " (17.8cm) of water (fuel alarm w/water <br />present) <br />Operating temperature <br />-40 to +140°F (-40 to +60°C) <br />Dimensions <br />-111, -121, -211, -221 versions 22" (55.9cm) high, 2.2" (5.6cm) dia.; -112, -122, -212, -222 versions 34" (86.4cm) high, 2.2" <br />(5.6cm) dia. <br />Compatible consoles <br />TLS-450/TLS-450PLUS, TLS4/8601 Series, TLS -350 Series <br />Console Interface <br />Module <br />TLS -350 Series - Smart Sensor Interface Module, 8 sensor input, -P/N 329356-004 <br />857080-221 <br />TLS-450/TLS-450PLUS - Universal Sensor Module (USM), 16 sensor input, P/N 332812-001 <br />857080-222 <br />TLS4/8601 Series - Universal Sensor Input Output Module (USIOM) (AC ver.), 12 sensor input, P/N 333238-001; (AC ver.), 6 <br />sensor input, P/N 333238-002; (DC ver.), 12 sensor input, P/N 333238-003; (DC ver.), 6 sensor input, P/N 333238-004 <br />Maximum number of <br />sensors monitored <br />TLS -350 Series (48) <br />per <br />console <br />TLS-450/TLS-450PLUS (32) <br />Weatherproof junction box <br />TLS4/8601 Series (12) <br />Compatible fuels <br />100% Gasoline and blends with up to 1590 Ethanol; Diesel; Bio -Diesel; Kerosene; Jet fuel; Aviation Gas; Waste Oil; Motor Oil <br />'For additional third party evaluation data see: hftp://www.nwglde.org/evals/veeder_root_x.html <br />Table 3. Mag Sump Sensor Form Numbers <br />Form <br />Number <br />Product <br />Measurement Leak Fixed <br />Limit Detect Threshold <br />857080-111 <br />Gasoline & <br />Diesel <br />12" (30.5cm) No No <br />857080-112 <br />24" (61cm) No No <br />857080-121 <br />12" (30.5cm) No Yes** <br />857080-122 <br />24" (61cm) No Yes** <br />857080-211 <br />12" (30.5cm) Yes No <br />857080-212 <br />24" (61cm) Yes No <br />857080-221 <br />12" (30.5cm) Yes Yes** <br />857080-222 <br />24" (61cm) Yes Yes** <br />**This version has a fixed water warning of 1.7" (4.32cm), water alarm of 3.0" <br />(7.6cm)and an alarm upgrade delay of 48 hours. <br />Miscellaneous <br />• Universal Sensor Mounting Kit (optional) - <br />P/N 330020-012 (see Fig. 2) <br />• Standard cable length - 10 feet (3m) <br />U -channel <br />Dispenser <br />containment <br />sump <br />Brackets, clamp, etc., <br />1/2^ NPT <br />from optional Universal <br />cord grip <br />sensor mounting kit <br />supplied <br />w/cable <br />Product <br />I Rigid <br />line <br />conduit <br />IMPORTANT!to <br />.. NOT MOUNT.•. <br />FLEXIBLE PRODUCT LINE. <br />console <br />I <br />I <br />I <br />Sensor <br />Weatherproof junction box <br />Sea <br />8 <br />IncorrectCorrect <br />