EHD Program Facility Records by Street Name
>
C
>
CENTER
>
121
>
2300 - Underground Storage Tank Program
>
PR0543446
>
INSTALL 2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/3/2019 10:52:47 AM
Creation date
1/16/2019 2:16:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2019
RECORD_ID
PR0543446
PE
2351
FACILITY_ID
FA0024656
FACILITY_NAME
7-ELEVEN #38153
STREET_NUMBER
121
Direction
S
STREET_NAME
CENTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
CURRENT_STATUS
01
SITE_LOCATION
121 S CENTER ST
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
631
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
YEEUER-ROOT <br />IN STATION DIAG <br />THE KEY TO CALIFORNIA COMPLIANCE <br />C� VEEDER-ROOT <br />Veeder-Root's California Air Resources <br />Product Components <br />Board (CARB) certified In -Station <br />i <br />Diagnostics (ISD) system provides the <br />• Assist Vapor Flow Meter — Designed to <br />d <br />most accurate vapor recovery detection <br />withstand the harsh vapor recovery <br />= r. <br />available in the industry. <br />environment found in systems with vapor <br />vacuum pumps. It provides ISD with the <br />Veeder-Root's ISD system continuously <br />volume of vapor recovered during vehicle <br />TLS -350 <br />monitors the vapor recovery equipment, <br />refueling for continuous vapor collection <br />maintains test records, provides test <br />monitoring <br />reports, and generates warnings or <br />Balance Flow Meter —Designed for use <br />;, •- <br />alarms following equipment failure. <br />in pressure sensitive balance systems to <br />�. <br />Vapor Flow Meter <br />-- p <br />The Veeder-Root ISD system can be <br />maintain accuracy and minimize false <br />` <br />alarms. It provides ISD with the volume of <br />added to any TLS -350 console. This <br />vapor recovered during vehicle refueling for <br />provides you with a cost effective <br />continuous vapor collection monitoring <br />solution with the Veeder-Root quality <br />` <br />and support that you expect. <br />• Vap or Pressure Sensor — Provides ISD with <br />tank ullage pressure for vapor containment <br />leakage and overpressure monitoring <br />The Most Installed ISD Solution <br />• ISD Software Enhancement Module <br />StartingSeptember 2010, ISD is <br />p <br />(SEM) — Unlocks the ISD software in the <br />�F u <br />required on all gasoline dispensing <br />TLS -350 to provide continuous vapor <br />n <br />facilities with an annual throughput over <br />recovery monitoring <br />-- " <br />600,000 allons. <br />g <br />Vapor Pressure Sensor <br />• NVMEM 2 Board —Provides memory <br />Whether assist or balance vapor <br />expansion necessary for ISD report storage <br />recovery, over 90% of California <br />customers have selected Veeder-Root's <br />ISD system. New stations select the <br />Benefits of the Veeder-Root ISD System <br />Veeder-Root balance ISD solution due to <br />Exceeds Compliance Requirements <br />Cost Effective Solution <br />simpler nozzle alarm requirements. <br />• CARB certified with all approved <br />• ISD OEM can be added to any <br />Veeder-Root's ISD is the only certified <br />hanging hardware, providing California <br />TLS -350 console, leveraging existing <br />solution that supports all vapor <br />customers with the most options <br />TLS -350 equipment <br />processor configurations and all certified <br />*Maximizes site uptime using Single <br />• Minimizes initial equipment and <br />vapor recovery nozzles. <br />Dispenser Shutdown functionality <br />installation costs <br />Flexible shutdown solutions allows <br />• Flexible ISD solution certified with all <br />• ISD Sensors can share wiring conduit <br />customers to choose between STP <br />Vapor Processor con igurations <br />with other Veeder-Rout intrinsically <br />shutdown, single dispenser shutdown or <br />• CARB certified to meet all ISD performance <br />safe (IS) sensors <br />use both configurations. <br />requirements as defined by CP201 <br />• Simple installation, compatible with all <br />including at least a 95% probability of <br />Dispensers <br />failure detection while operating at no more <br />.Single Dispenser or STP Shutdown <br />than a 1% probability of false alarms <br />*Continuous monitoring identities failed <br />• Wireless option available <br />vapor recovery equipment during warranty <br />• Veeder-Root warranty for one year from <br />periods without expensive manual testing <br />date of installation for all new ISD <br />VEEDER-ROOT <br />components <br />
The URL can be used to link to this page
Your browser does not support the video tag.