CID <br /> U W co `o <br /> 36'-0" Z C) ai <br /> z <br /> N c, <br /> 67'-0" 6" 10'-0" - Z °s° <br /> 23'-o" 1 a'-6" _ <br /> 10 -6 23 -0 A � <br /> Z O z � <br /> _ � <br /> Lu <br /> BRIDGING @ 3 POINTS BRIDGING @ POINTS <br /> 0 12W12x19 PURLINS Z Z w n o E" o <br /> OUTLINE OF MANSARD ICo <br /> PURLIN BRIDGING PER 4'8 _ <br /> ROOF ABOVE <br /> ( ) SEE DETAIL 3 SHEET CS3, o W14x30 BEAMS 0 Z w <br /> SHEET CS2 TYP. (6) ROWS AS SHOWN �r _ - _ W <br /> � � <br /> _ I I O <br /> �W12x19 I I - - I I I I W12x19� o <br /> O I mo o <br /> n � m` a w CD <br /> H <br /> j II HSS 12"x12"x4l II I I ll / I I © FASCIA FRAMING @ 3" 20 GA. <br /> I 11 COLUMN (TYP.} it I I li i 1 4'-0" O.C. MAX. DECK PANEL a <br /> I I SII - I - AROUND ENTIRE <br /> ( -I CANOPY PERIMETER <br /> W12x19 / I I / I I 1 W12x19 <br /> o ,_ <br /> 0 o I j j f X 3'-6"4 DRILLED PIER X I o v a_ o <br /> M I f 1 I I I co HSS 1"" � v oo �FOOTING (TYP ) xxa. W12x19 COLUMN (TYP.) w o <br /> I (� I I ( 1 1 11 lLd <br /> _ I _ I - y / _ I _ - I- - / I I _ R CD >_ I- <br /> I <br /> \ I I / -1 - I I I I I I I 1 `i 6" MIN. CONCRETE SLAB, z o Z <br /> 11 I I 11 I I II I DESIGN BY OTHERS Q Q co <br /> N W12x19 I I I 1 Il I 1 11 W12x19 o <br /> - <br /> �/ - - - - - - - - - - � -- __ -, I <br /> PURLIN SPLICE PER <br /> OVERFLOW SCUPPERS DRAIN LATERAL DETAIL 7 SHEET CS3, d- I T ~ <br /> PER DETAIL 9 SHEET TO COLUMN (TYP.) TYP. (4) PLACES _ _ <br /> II € <br /> CS3, TYP. (6) PLACES <br /> � ® � 1p t - g `if' DRILLED CONCRETE z <br /> VA PIER (BY GENERALz LO o <br /> FRAMING PLAN CONTRACTOR) <br /> � O 0 <br /> J <br /> 3'-6"4 34z 0 <br /> SCALE: 1/8"=1'-0" F _J <br /> W <br /> M � 0 <br /> w Y <br /> O r 0 <br /> SECTION ZELEVATION Q <br /> SCALE: 1/4"=11"_C <br /> �3: 00 <br /> 3" PVC DRAIN PIPE IN COLUMN STRUCTURAL NOTES: o <br /> o <br /> A. GENERAL 8 H <br /> STEEL COLUMN 1 11 1. The contractor shall verify all conditions and dimensions at the site. 6 0 <br /> 4" PVC SLEEVE AND ELBOW ii it FUEL RESISTANT JOINT SEALANT 2. observation visits ec the site p the design engineer shall neither be <br /> NOTE: GENERAL CONTRACTOR TO PROVIDE 3" SPECIAL INSPECTIONS construed as inspection nor approval of construction. � =Q�oR byryo <br /> I I (BY GENERAL CONTRACTOR) 3. During and after construction, builder and/or owner shall keep loads on � <br /> EXTEND ROD 9" ABOVE FOOTING I MINIMUM CONCRETE COVER AROUND the structure within limits of design loads. 1 <br /> ILI 6" CONCRETE SLAB, AND/OR OVER BURIED COLUMN, BASE 1. STRUCTURAL STEEL - Special inspection required in 4. Typical details and sections shah apply where specific details are not o � <br /> 4"f NON-SHRINK GROUT PLATE AND ANCHOR RODS TO accordance with the quality assurance inspection shown. Z od 0 " o <br /> THICKEN ABOVE FOOTING PROTECT THEM FROM CORROSION. requirements of AISC 360 (CBC 1705.2.1). B. 2016 CALIFORNIA BUILDING CODE DESIGN CRITERIA w <br /> (BY GENERAL CONTRACTOR) I A. Roof Live Load . . . . . . . . . . . . . . . . .20 psf (reducible) °d b <br /> i 2. WELDING - Special inspection is not required where B. Canopy Dead Load . . . . . . . . . . . . . . .10 psf 3�S�oaa <br /> STEEL COLUMN 3" PVC DRAIN welding is performed in an approved fabricator shop Mansard Dead Load . . . . . . . . . . . . . .10 psf <br /> C. Ground Snow Load Py . . . . . . . . . . . . .N.A. <br /> - 1 PIPE IN COLUMN as per CBC 1705.2, D. Ultimate Design Wind Speed V"It . . . . . . . 110 mph } _ <br /> 1=III I I=� I- " I 3. CONCRETE - Special inspection required for Risk Category . . . . . . . . . . . . . . . . . II m <br /> 4 PVC SLEEVE AND ELBOW Exposure . . . . . . . . . . . . . . . . . . . . C cn <br /> _ I I FUEL RESISTANT JOINT SEALANT concrete footings per CBC 1705.3. Component & Cladding . . . . . . . . . . . . See ASCE 7-10 Chapter 30 Or- <br /> (BY <br /> `� <br /> FILL WITH CONCRETE AFTER I (BY GENERAL CONTRACTOR) 4. ANCHOR RODS - Periodic special inspection of E. Earthquake Design Data <br /> - - _ = I COLUMN HAS BEEN INSTALLED FIELD NOTE: LEAVE A 36 I Importance Factor le • • • • • • • • • . . . 1.0 Q Q <br /> _ w _ anchor rod installation required per CBC Table 1705.3. o i <br /> _N _ _ - - I MIN. BLOCKOUT AT FOOTING SS . . . . . . . . 0.912g Spg . . . . . . . 0.690g <br /> 6" CONCRETE SLAB, THICKEN 5. NON-SHRINK GROUT - Special inspection required S1 . . . . . . . . 0.3369 Spy . . . . . . . 0.3879 fi <br /> ``' � - _ _ _ - (4) 11"0 F1554-55 ANCHOR RODS FOR COLUMN ERECTION 111 TO 12" ABOVE FOOTING as directed by the manufacturer. Site sass . . . . . . . . . . . . . . . . . . . D W <br /> WITH HEAVY HEX BOTTOM NUT 6. SOILS - Special inspection by the geotechnical Seismic Design Category . . . . . . . . . . . D <br /> Seismic Force Resisting System . . . . . . . 0.2. Steel ordinary cantilever d <br /> TACK WELDED 1" FROM END OF ILII engineer is required per CBC 1705.6. column systems <br /> 7. DRILLED CONCRETE PIERS - Special inspection Design Base Shear . . . . . . . . . . . . . . 22.26 kips <br /> ROD PROVIDED BY JIMCO INSTALLED <br /> I I Seismic Response Coefficient Cs . . . . . . 0.55 9 1 <br /> II ll BY GENERAL CONTRACTOR _ �{ 1 - <br /> required for cast-in-place dee foundations per <br /> - - =I I_ I q P P P Response Modification Factor R . . . . . . . 1.25 <br /> =I (iI CBC 1705.8. C. FOUNDATION s Z Z <br /> -1 = I-- TI -III I III-I I� 1. Allowable Bearing Pressure: el J. psf for spread footings per the Z O <br /> geotechnical report by Daniel J. Trisler, P.E. of Hart Crowser, Inc. � � y <br /> z li -III _ „ I-III -III dated January 5, 2017 (Project No. 159144-3 . 9 ) ; w <br /> I III-I EXTEND ROD 9 2. Passive Earth Pressure: 300 psf/ft of depth (per eotech <br /> II II 4 ± NON-SHRINK GROUT (BY (per geotech) J <br /> ( � I1 -III-I I-_ <br /> _ ABOVE FOOTING GENERAL CONTRACTOR} 3. Coefficient of Friation: 0.35 <br /> a I I^ 4. Skin Friction: 1200 psf acting below a depth of 5 feet and below all W <br /> _ undocument fill soils (per geotech) <br /> -i II _III-III -I ® o <br /> (-III- SEISMIC FORCE RESISTING SYSTEM (SERB) INFO 5. Site soils shall be prepared for the foundation in accordance with the <br /> II II = = - <br /> cy - #4 TIES @ 16" O.C. MAX. - _ - ( I I iI I - A. Refer to AISC 341-1Q Section A4 and ASCE 7-1Q. geotechnical report referenced above (remove all undocumented fill Lli <br /> o- <br /> ' - ! _ _� _ : �_ _ _ �- _ under spread footings). ai z <br /> _ I _ _ _ _ = I=) B. Designation of the SFRS: G.2. Steel ordinary D. CONCRETE AND REINFORCEMENT o <br /> z II II WITH (3) IN TOP 5" OF _ I r CD m cantilever column systems (ASCE 7-10 Table 12.2-1) 1. Concrete Footings (Exposure Classes F0, so, P0, Co) f'c=3000 p.s.i., w 0- o <br /> Z II = _ _ _ = II FOOTING AND @ 4" O.C. IN III- cm ( ) v W <br /> •7 J Type II cement, w/ ratio=0.45, Air Content=5% t1.5% <br /> 0o v - See AISC 341-10 Section E5 (OCCS). y, <br /> 1 "I '� (9) #5 BARS EACH 2. Slabs on grade (Exposure Classes Ft, S0, P0, CO) Type Il cement, <br /> II 11 THE TOP 24 OF FOOTING o C. R = 1,25, Cs = 0.55 fc=3500 ps.i. cn <br /> w ao "' WAY AT TOP AND 14 <br /> C/) CONCRETE II II - _ _ D. Analysis Procedure = Equivalent Lateral Force 3. Rebar; ASTM A615 Grade 60. F d <br /> U-1 l II d z - _ _; _ _ -. - -.- - s - -. _ BOTTOM OF FOOTING 4. Grout under steel base plates shall be non-shrink rout complyingwith a <br /> DRILLED PIER E. Members and Connections that are part of the SFRS: p 9 z <br /> _ _ _ _ _ _ _ <br /> ASTM C1107, f c=5000 ps.i., and installed per manufacturers <br /> (BY GENERAL p #4 TIES �N I t �= <br /> a. Columns recommendations. � <br /> v CONTRACTOR N ( I I- 1" b. Column Base Connection 5. The general contractor is responsible for locating top of footing <br /> II ''o v - (4) 12 0 F1554-55 ANCHOR RODS WITH elevations as required for underground plumbing and electrical. <br /> Il HOOK DETAIL c. Footings <br /> HEAVY HEX BOTTOM NUT TACK WELDED 1" F. Protected Zones - N.A. E. STRUCTURAL STEEL <br /> _ _ _ _ _ � � � 1. Structural steel shall be fabricated and erected in accordance with the <br /> FROM END OF ROD PROVIDED BY JIMCO G. See details and notes for connection configurations, latest edition of the following: m <br /> Il II CONCRETE FOOTING INSTALLED BY GENERAL CONTRACTOR <br /> 9 g i- <br /> ll material specifications, and sizes. a. AISC "Specifications for the Design Fabrication and Erection of m o 00 <br /> {BY GENERAL Structural Steel for Buildings." z Y j <br /> CONTRACTOR) H. Weld filler materials for welds part of the SFRS: b. AISC "Code of Standard Practice" excluding the following sections: = 3 = W N w <br /> 90' HOOKS (10) #8 VERTICALS a. Yield Strength = 58 ksi min. 4.4, 4.4.1, 4.4.2, and 7.15. ' (3 o C3 o <br /> AS SHOWN WITH b. Tensile Strength = 70 ksi min. c. AISC "Specifications for the Design of Cold Formed Structural <br /> 3'-6"0 STANDARD 180' c. Elongation = 22% min. Members" A36p g JOB N0. <br /> d. CVN Toughness = 20 ft-Ib min. @ 0' F 2. Structural steel shall conform 4 ASTM min for lutes and angles, <br /> 2'-6" HOOK @TOP (AS g ASTM A500 grade B for HSS (42 k.s.i. min. pipes and 46 k.s.i, min <br /> SHOWN) SPREAD FOOTING OPTION See details and notes for other welding requirements. for squares and rectangles), and ASTM A992 grade 50 for all beams 18- 1662R1 <br /> J. Demand Critical Welds - N.A. and purlins. Base plates, cap plates, and cap plate stiffeners (if any) <br /> DRILLED PIER DETAIL SCALE: 1/2"=1'-0" i. <br /> K. Lowest Anticipated Service Temperature - 0' F shall be ASTM Abe rf= ed by c <br /> PIER SECTION p p 3. All welding shall be performed by certified welders in accordance with 0 DWG, N0. <br /> the American Welding Society using E-70xx electrodes. 9 <br /> SCALE: 1/2"=l'-O" 4. On all bolted connections, use ASTM A307 bolts unless otherwise CS 1 <br /> specified (no special inspection required.) <br /> 5. Metal roof deck shall be 20 ga. ASTM A653 grade 40. OF 3 SHEETS <br />