Laserfiche WebLink
2' a�� Ly' SAN J OA Q U I N Environmental Health Department <br /> a' I ' a `� Linda Turkatte , REHS , Director <br /> " <br /> " COUNTY <br /> c . v Kasey Foley, REHS , Assistant Director <br /> gUi6 Greatness grows here . <br /> PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Michael Kith , REHS <br /> October 14 , 2019 Melissa Nissim , REHS <br /> MEGAN MITCHELL <br /> ELITE IV CONTRACTORS <br /> 2535 WIGWAM DR <br /> STOCKTON , CA 95205 <br /> SR0081212 <br /> Re : QUICK SHOP <br /> 2072 W YOSEMITE AVE <br /> MANTECA , CA 95337 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of <br /> the application for a permit to replace the diesel spill container, install new dispensers and Bravo <br /> conversion frames on the underground storage tank ( UST) system at the above noted address . <br /> The permit has been approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District <br /> for any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work . All new addenda supersede the previous ones . <br /> 3 . Contact Shewit Woldearegay at (209) 468 - 0216 to arrange the following appointments ( a <br /> 48- hour notice is required for inspection appointments) , <br /> • Corrosion protection : Verify corrosion protection for direct bury spill bucket prior to <br /> backfilling . <br /> • Spill bucket test : Verify minimum 5 -gallon capacity and pass a one hour hydrostatic <br /> test ( or equivalent) . Proper drainage must also be verified . <br /> • Since concrete will be broken near the diesel tank , a secondary containment test must <br /> be performed on the diesel tank once concrete is poured in accordance with the <br /> manufacturer' s guidelines . <br /> • Verification of the dispenser footprints contained by the under dispenser containment <br /> sumps ( UDCs ) . <br /> • Visual inspection of the piping within the dispensers . <br /> Please be aware that the facility cannot receive fuel in the diesel tank prior to the <br /> EHD inspection and approval . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board (may be <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468 -3420 1 F 209 464-0138 1 www. sjgov . org/ehd <br />