Laserfiche WebLink
S b N J 0 A Q U I N Environmental Health Department <br /> COUNTY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> QUICK SHOP 2072 W YOSEMITE AVE, MANTECA December 18, 2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 101 HSC 25284 Failed to obtain a permit to operate from the EHD including but not limited to unpaid permit fees. <br /> A permit to operate the 100 octane and 110 octane UST system has not been issued. No person may own or <br /> operate an UST unless a permit for its operation has been issued by the local agency to the owner or operator of the <br /> UST system. Immediately obtain a permit to operate a 100 octane and 110 octane UST system from the EHD. An <br /> "Operating without a Permit" penalty applies. <br /> This is a Class I violation. <br /> 103 HSC 25292.2,25299.30 Failure to submit and maintain complete and current financial responsibility documents. <br /> Current Financial responsibility documents have not been submitted to the EHD. The chief financial officer letter is <br /> missing the date for the witness signature. Current financial documents are required to be submitted annually. <br /> Immediately log into the California Environmental Reporting System (CERS)at http://cers.calepa.ca.gov/, and <br /> upload the required documents. <br /> This is a repeat violation, Class 11. <br /> 110 CCR 2637(e), 2637(f)Failed to submit"Secondary Containment Testing Report Form"within 30 days after the test. <br /> Secondary containment testing was performed on 4/25/18 and a test report was submitted on 12/18/18, 8 months <br /> late. A copy of the test report must be submitted within 30 days of the tests. Take all necessary precautions to <br /> ensure testing and submittal of test reports are performed in a timely manner. <br /> This is a repeat violation, Class 11. <br /> 111 CCR 2638(a)&(b), 26410) Failed to test monitoring and leak detection equipment annually. <br /> Annual monitoring system certification and leak detector testing were last performed on 9/19/17 and was completed <br /> on 12/18/18, 3 months past due. These tests are required once every 12 months. Take all necessary precautions <br /> to ensure testing is performed in a timely manner. <br /> This is a repeat violation, Class 11. <br /> 113 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> Annual monitoring system certification, leak detector testing, and spill container testing was performed on 9/19/17 <br /> and a test report was submitted on 3/23/18 , 6 months late. A copy of the test report must be submitted within 30 <br /> days of the tests. Take all necessary precautions to ensure testing and submittal of test reports are performed in a <br /> timely manner. <br /> This is a repeat violation, Class 11. <br /> FA0004625 PR0231426 SC333 12/18/2018 <br /> EHD 23-01 Rev.09/28/2018 Page 4 of 7 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />