Laserfiche WebLink
UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br /> Type of Action ❑Installation Inspection ❑Repair Inspection 0 36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10181669 6/11/2019 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> QUICK SHOP #1 <br /> Business Site Address City ZIP Code <br /> 2072 YOSEMITE AVE MANTECA 95337 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> David Winkler (209) 744-0112 <br /> Contractor I Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 08-1739 Ex.3/31/2020 8883059-UT 1/29/2020 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> FF- EBW , Phil-Tite & EVR Phase 1 1009853708 Ex 11/29/20 OPW 104-633 Ex 3-14-2020 <br /> Emco #3207 Ex. 11/16/20 ATG: VR: B34975 ATG: 2/8/20 INCON 1009853708 Ex.11/30/2020 <br /> III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method ❑x Manufacturer Guidelines(Specify): <br /> Used: REMOVED OPW DROP TUBES <br /> ❑Industry Code or Engineering Standard(Specify): <br /> ❑Engineered Method(Specify): <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages 5 <br /> TANK ID:(By tank number,stored product,etc.) 87-1 91 100 110 <br /> What is the tank inside diameter?(Inches) 95.75 95.75 95.75 95.75 <br /> Is the fill piping secondarily contained? ❑Yes FAI No ❑Yes 0 No ❑Yes [E No ❑Yes 0 No <br /> Is the vent piping secondarily contained? ❑Yes 0 No ❑Yes 0 No ❑Yes 0 No ❑Yes ❑x No <br /> Overfill Prevention Equipment Manufacturer(s) OPW OPW OPW <br /> 61So 61SO 61So <br /> What is the overfill prevention equipment response ❑x Shuts Off Flow ❑x Shuts Off Flow 0 Shuts Off Flow ❑Shuts Off Flow <br /> when activated? <br /> (Check all that apply.) ❑Restricts Flow ❑Restricts Flow ❑Restricts Flow ❑Restricts Flow <br /> ❑AN Alarm ❑A/V Alarm ❑AIV Alarm ❑AN Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes ❑x No ❑Yes 0 No ❑Yes ❑X No ❑Yes 0 No <br /> At what level in the tank is the overfill prevention set <br /> to activate?(Inches from bottom of tank.) 84.5 84.5 85.5 85 <br /> What is the percent capacity of the tank at which the <br /> overfill prevention equipment activates? 93 93 94 93 <br /> Is the overfill prevention in proper operating condition ❑x Yes ❑x Yes 0 Yes X Yes <br /> to respond when the substance reaches the <br /> appropriate level? ❑No(Specify in V.) ❑No(Specify in V.) ❑ No(Specify in V.) ❑ No(Specify in V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results 0 Pass ❑Fail I 0 Pass ❑Fai`lj 0 Pass ❑ Fail X Pass ❑ Fail <br /> V. COMMENTS <br /> own <br /> Any items marked"Fail'must be explained in this section. Any additional comments m e o <br /> EfVELj <br /> JUN 11 2019 <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONRY21ING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordanceL-W'iNdra1Qrml r IWGM Title 23, <br /> Division 3,Chapter 16,Section 2637.2 and all the information contained herein is accurateDEPARTNIEN <br /> UST Service Technician Signature V <br /> If the facility has more components than this form accommodates,additional copies of this page may be attached. <br /> CERS=CaQfomia Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,AN=Audible and Visual <br />