My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
G
>
GUILD
>
715
>
2231-2238 – Tiered Permitting Program
>
PR0526078
>
COMPLIANCE INFO
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:57 AM
Creation date
1/29/2019 11:31:47 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2231-2238 – Tiered Permitting Program
File Section
COMPLIANCE INFO
RECORD_ID
PR0526078
PE
2232
FACILITY_ID
FA0016140
FACILITY_NAME
LUSTRE CAL NAMEPLATE CORPORATION
STREET_NUMBER
715
Direction
S
STREET_NAME
GUILD
STREET_TYPE
AVE
City
LODI
Zip
95240
APN
04931024
CURRENT_STATUS
01
SITE_LOCATION
715 S GUILD AVE
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\TP\TP_2232_PR0526078_715 S GUILD_.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN J O A Q I I I N Environmental Health Department <br /> -COUNTY <br /> Conditionally Authorized Treatment Facility Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> LUSTRE CAL NAMEPLATE CORPORATION (209) 370-1600 January 25, 2019 <br /> Facility Address: CERS ID: <br /> 715 S GUILD AVE, LODI, CA 95240 10185087 <br /> Inspection Contact: Title: Phone: <br /> Chris Colbert Vice President-Op (209)234-6264 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION -Operating Permit 12232- HAZARDOUS WASTE CA FACILITY <br /> Consent For: Consent Given By: <br /> Nx Inspection xN Photos Nx Samples I Chris Colbert, Vice President- Op <br /> CCR=Tide 22 California Code of Regulations HSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25201(a) Failed to obtain a permit to treat hazardous waste V E R ❑COS <br /> 102 HSC 25200.3(e) Failed to submit an onsite hazardous waste treatment notification V r- R r COS <br /> 103 HSC 25200.3(k) Failed to submit an amended hazardous waste treatment notification V n R o COS <br /> 104 CCR 67450.13(a)(1) Failed to submit an estimate of closure costs L V U R n COS <br /> 105 CCR 67450.13(x)(2) Failed to adjust the closure cost estimate by March 1 ■V R e COS <br /> 106 CCR 67450.13(a)(4) Failed to revise the closure cost estimate whenever a change increases the cost of closure V n R ❑COS <br /> 107 HSC 25200.14(b)(1) Failed to submit a phase one environmental assessment checklist V ❑R c COS <br /> 108 CCR 25185(c)(3) Failed to submit a written response within 30 days of receiving an inspection report V R r:COS <br /> 109 HSC 25300.3(e)(3) Failed to submit correct CA information in CERS ■V c R ❑COS <br /> 110 HSC 25404(e)(4) Failed to report program data electronically n V e;R n COS <br /> 111 HSC 25404.1.2 Failed to submit a certification and written response within 30 days for minor violations V a R COS <br /> On Site Records <br /> 201 HSC 25200.3(c)(4) Failed to comply with hazardous waste tank system requirements V c R -j COS <br /> 202 CCR 66265.192(k) New hazardous waste tank assessment is incomplete --V R u COS <br /> 203 CCR 66265.192(h) Failed to reassess the hazardous waste tank system every five years or service life of the system ■V r R COS <br /> 204 CCR 66265.191(g) Failed to have a complete existing hazardous waste tank system assessment V r R r.i COS <br /> 205 CCR 66265.191 Failed to annually certify an existing hazardous waste tank system without secondary containment V r,R ❑COS <br /> 206 HSC 25200.3(c)(6)/(7) Failed to maintain written operating instructions and waste treatment records for five years ■V ■R n COS <br /> 207 HSC 25200.3(c)(5)/(7) ailed to maintain a written inspection schedule and log of inspections for five years i V u R ❑COS <br /> 208 CCR 66265.192(a) Failed to obtain PE certified hazardous waste tank assessment prior to placing the system in service V R COS <br /> 209 CCR 66265.192(1-m) Failed to obtain CUPA approval prior to the replacement of a functionally equivalent tank V u R u COS <br /> 210 HSC 25200.3(c)(7) Failed to keep adequate wastewater pretreatment compliance records for five years V r,R n COS <br /> Observations <br /> 301 HSC 25200.3(a-b) Failed to meet conditions for treating hazardous wastes under grant of conditional authorization =V E R E COS <br /> 302 CCR 66264.175(a-b) Failed to provide secondary containment for conditionally authorized treatment in containers V u R i!COS <br /> 303 CCR 66265.17(a) Failed to protect containers from sources of ignition or reaction V E R =COS <br /> 304 HSC 25200.3(c)(1) Failed to post signs or have adequate security V E R COS <br /> FA0016140 PR0526078 SCO01 01/25/2019 <br /> EHD 22-05 Rev.11/13/2018 Page 1 of 6 Conditionally Authorized Treatment Facility OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.