My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
K
>
KETTLEMAN
>
800
>
1600 - Food Program
>
PR0161886
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/18/2020 10:20:54 AM
Creation date
1/29/2019 4:05:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
1600 - Food Program
File Section
WORK PLANS
RECORD_ID
PR0161886
PE
1617
FACILITY_ID
FA0000511
FACILITY_NAME
ARCO AM/PM 7049
STREET_NUMBER
800
Direction
E
STREET_NAME
KETTLEMAN
STREET_TYPE
LN
City
LODI
Zip
95240
APN
06206042
CURRENT_STATUS
01
SITE_LOCATION
800 E KETTLEMAN LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
JCastaneda
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CLIENT: <br /> CAL-GREEN NOTES CAL-GREEN NOTES - ADDITIONAL bp <br /> PLAN KEYNOTES: <br /> O SMOKE DETECTOR IN THE SUPPLY AIR PLENUM TO <br /> SHUT DOWN PACKAGED ROOFTOP UNIT UPON PST <br /> THIS PROJECT SHALL BE COMPLIANT TO 2013 CGBSC, 5UT NOT CONTRACTOR SHALL COMPLY WITH THE FOLLOWING CAL-GREEN SMOKE DETECTION. � <br /> LIMITED TO THE FOLLOWING: REQUIREMENTS AS LISTED BELOW: <br /> O FULL SIZE SUPPLY AIR DUCT FROM RTU-1 ON <br /> ROOF. <br /> 1. TEMPORARY VENTILATION: IF THE VENTILATION SYSTEM IS USED DURING 5.410.4 Testing and adjusting. Testing and adjusting of systems shall be <br /> CONSTRUCTION, required for buildings less than 10,000 square feet. O3 FULL SIZE RETURN AIR DUCT FROM RTU-1 ON <br /> USE RETURN AIR FILTERS WITH A MERV 8 RATING OR 30% COMPLAINT TO ROOF. <br /> ASHRAE 52.1 -1999. REPLACE ALL FILTERS IMMEDIATELY PRIOR TO <br /> OCCUPANCY o 5.410.4.2 Systems. Develop a written plan of procedures for ® FULL SIZE SUPPLY AIR DUCT FROM RTU-2 ON <br /> testing and adjusting systems. Systems to be included for testing ROOF. <br /> 2. COVERING OF DUCT OPENINGS OF MECHANICAL EQUIPMENT DURING and adjusting shall include at a minimum, as applicable to the <br /> CONSTRUCTION: project: O5 FULL SIZE RETURN AIR DUCT FROM RTU-2 ON <br /> AT THE TIME OF ROUGH INSTALLATION AND DURING STORAGE ON THE ROOF. <br /> CONSTRUCTION SITE UNTIL FINAL START UP OF THE HEATING, COOLING AND HVAC systems and controls <br /> VENTILATING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION Indoor and outdoor lighting and controls © 24"X20" SUPPLY AIR PLENUM. <br /> COMPONENT OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL Water heating systems <br /> OR OTHER METHODS ACCEPTABLE TO THE ENFORCING AGENCY TO REDUCE THE Renewable energy systems O7 24"X20" RETURN AIR PLENUM. lor <br /> AMOUNT OF DUST, WATER AND DEBRIS WHICH MAY ENTER THE SYSTEM. ARCO <br /> • Landscape irrigation systems <br /> 3. ALL HVAC, REFRIGERATION AND FIRE SUPPRESSION EQUIPMENT (IF ANY) SHALL Water reuse systems ® TYPE 2 U.L. LISTED HOOD. <br /> NOT CONTAIN CFC'S OR HALONS COMPLIANT TO CGBSC SECTION 5.714.8.1 O9 14"0 EXHAUST DUCT UP TO KEF-1 ON ROOF. BP WEST COAST PRODUCTS,LLC <br /> 5.410.4.3 Procedures. Perform testing and adjusting procedures in <br /> 4• ALL HVAC EQUIPMENT SHALL BE LISTED BY A NATIONALLY RECOGNIZED accordance with industry best practices and applicable standards on 10 PROGRAMMABLE THERMOSTAT, 48" AFF. <br /> TESTING LABORATORY AND PROPERLY LABELED COMPLIANT TO ARTICLE 110.2 each system as determined by the building official. <br /> 1 1 CO2 SENSOR, 60" AFF. &ViA& <br /> 5. ALL FACTORY MADE AIR DUCTS SHALL BE CLASS I OR 0 LISTED DUCTS <br /> COMPLIANT TO CMC 604.3 0 5.410.4.3.1 HVAC balancing. In addition to testing and adjusting, <br /> before a new space— conditioning system serving a building or space 12 THERMOSTAT REMOTE SENSOR, 48" AFF. <br /> is operated for normal use, the system shall be balanced in <br /> 6. ALL LINING MATERIALS INSTALLED WITHIN DUCTS AND PLENUMS SHALL HAVE A accordance with the procedures defined by the Testing Adjusting and 13 THERMOSTAT TO ENERGIZE EF-2, SET FAN TO <br /> MOLD, HUMIDITY AND EROSION RESISTANT SURFACE THAT MEETS THE Balancing Bureau National Standards; the National ENGERGIZE AT 77•F. <br /> REQUIREMENTS OF THE REFERENCED STANDARD COMPLIANT TO CMC, Environmental Balancing Bureau Procedural Standards; or <br /> Associated Air Balance Council National Standards or as approved by 0 V <br /> CHAPTER 17, SECTION 605.0 the building official. 14 MANUAL VOLUME DAMPER. Z = <br /> 7. A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE DEVELOPMENT 15 8"0 EXHAUST AIR DUCT UP TO ROOF JACK. sG SCO <br /> RATING OF NOT MORE THAN 50 FOR MATERIALS EXPOSED WITHIN THE DUCTS OR 5.410.4.4 Reporting. After completion of testing, adjusting and <br /> balancing, provide a final report of testing signed by the individual 16 12"0 EXHAUST AIR DUCT UP TO EF-2 ON ROOF. T�HG ENG�N�� <br /> PLENUMS SHALL BE COMPLIANT TO CMC 602.2 responsible for performing these services. <br /> 8. INSULATION MATERIALS APPLIED TO THE EXTERIOR OF DUCTS SHALL BE 17 10"0 EXHAUST DUCT DOWN. <br /> COMPLIANT TO NUMBERED NOTE #8 THIS SHEET. 5.410.4.5 Operation and maintenance (0 & M) manual. 18215 72ND AVENUE SOUTH <br /> Provide the building owner or representative with detailed 18 NOT USED. KENT, WA 98032 <br /> operating and maintenance instructions and copies of (425)251-6222 <br /> g ADHESIVES, ADHESIVE BONDING PRIMERS, SEALANTS, SEALANT PRIMERS, guaranties/warranties for each system. 0 & M instructions shall be 19 OUTLINE OF ELECTRIC WATER HEATER. FOR DETAIL (425)251-8782 FAX <br /> CAULKS AND AEROSOL ADHESIVES AND SMALLER UNIT SIZES OF ADHESIVES OR <br /> CAULKING COMPONENTS SHALL COMPLY WITH VOC LIMITS COMPLIANT TO CGBS consistent with OSHA requirements in CCR, Title 8, Section 5142, and 2 SEE PLUMBING PLANS. <br /> 5.504.4 other related regulations. CIVIL ENGINEERING, LAND PLANNING, <br /> �0 AIR CURTAIN, SEE MO.1 FOR SPEC. SURVEYING, ENVIRONMENTAL SERVICES <br /> 10. AEROSOL PAINTS AND COATINGS SHALL MEET CGBS 5.504.3.1 , VERIFICATION OF o 5.410.4.5.1 Inspections and reports. Include a copy of all NO. DATE REVISION DESCRIPTION <br /> COMPLIANCE SHALL BE PROVIDED BY CONTRACTOR inspection verifications and reports required by the enforcing agency. <br /> — 04/28/17 APPROVED BY SCOTT WEST <br /> 0 PLAN PERMIT SUBMITTAL <br /> 1 08/22/17 CLIENT UPDATES <br /> 2Q 09/20/17 PLAN REVIEW COMMENTS <br /> A03/29/19 CLIENT REVISIONS <br /> TYPE=2 HOOD VELOCITY CALC 0 <br /> 5 <br /> 650 CFM / 14"0 (1 .069 SQ FT)=608 FPM Q <br /> 8 6 2 1 6 2 1 Q <br /> 0 <br /> 58T ER 58T ER 58T ER <br /> 1854 1854 E 4TI 18TI 4TIE Q <br /> E i IER 4 TIER 4 TIER 4 TIER <br /> 10 <br /> I SD-2 SD-2 RD-1 --____-- SEAL: <br /> 14"� �t o 200 200 850 " i 12 - I I <br /> 9 1 r—T r——�_1 QROFESS/p�9 <br /> (RTU-1) 10 16 —? �•� J I ' I '�= I lil 12"PD— <br /> F <br /> I SFS <br /> 11 <br /> (RTU-2) 10 T - 6 <br /> DTT i 12"0 <br /> 50 <br /> SD-2 <br /> 200 N 14" M-029816 <br /> k 6 S C j i EXP. 6-30-2020 <br /> » I 3 0 0 i 9 'CCHANC ' 0� <br /> - 12 , ^ �\\ 1 1 (RTU-2) ------ ----- ----- —____= orc K <br /> RD-1 -Lill �� \�� --- �LiJ�� �> 1 (RTU-2) 1-- �W <br /> I <br /> 850 ��_______�___ oo Date Signed: March 29, 2019 <br /> -- ------ RD-1 SD-2 RD-1 O 4 i i °°� <br /> 19 -- <br /> 2 I __ 10 O '/ T 13 " / 800 200 800 -� <br /> ^� I �0- ' SACRAMENTO <br /> w ENG/NEER/NG <br /> 2 r----1 CONSZ&TANTS <br /> SD—2 10555 Old Placerville Road12"b ro Sacramento, CA 95827-2503200 <br /> Phone: (916) 368-4468 <br /> —44 <br /> 9 <br /> 0O Fax: 916 368 <br /> — S � ------ <br /> -----� I <br /> www.saceng.com <br /> I 12 � j1 Jab Na. 17438O4RD-1 o5 <br /> v 51 <br /> DEVELOPMENT INFORMATION: <br /> ODLO ow RAZE AND REBUILD <br /> W <br /> III 2 o 1 ' 500 450 ' 12"0 I�' i I 2400 am/pm <br /> SD-2 I FUEL CANOPY w/ 8 MPD's <br /> 200 12"0 D I (TYP.) 14 I I I 24'X4$' CAR WASH <br /> 12 <br /> 1 1 (RTU-1) I I <br /> I <br /> (RTU-1) 1 -4__ I W <br /> 8I — J 1 III I I I I III O SITE ADDRESS: <br /> II III I I I I I I I III I � � I <br /> II 0__ 800 E KETTLEMAN LN <br /> SD-1 15 SD-1 4) <br /> 0 1 I @HIGHWAY 99 <br /> 100 SD-3 SD-3 I I I LODI,CALIFORNIA <br /> 2 ' t 500 450 ' 12 b III i i - <br /> / � I <br /> 500 \ I 12 III i �' 450 I I i FACILITY #TBD <br /> 7 II w <br /> DESIGNED BY- <br /> O • 18 I I M CHECKED BY: <br /> EF 2 — 4 T <br /> 2 ---- 0 ACN ------- ----------- DRAWN BY: <br /> 1 \ I VERSION: _ PROJECT NO: <br /> 12796 <br /> DRAWING TITLE: <br /> MECHANICAL <br /> FLOOR PLAN <br /> SHEET NO: <br /> ('1"�\ MECHANICAL PLAN PLAN <br /> M2 . 1 SCALE: 1 /411 = 1 '-011 <br />
The URL can be used to link to this page
Your browser does not support the video tag.